{"product_id":"tripp-lite-smx3000xlrt2ua-3kva","title":"Tripp Lite by Eaton SMX3000XLRT2UA UPS System - SMX3000XLRT2UA - Line-interactive UPS, 230 V AC, Rack\/Tower, Sine Wave, 2U, 230 V AC, IEC 60320 C20, SmartPro, 11.10 Minute, 3.90 Minute, 3 kVA\/2.70 kW","description":"Product Features:\u003cul class=\"spec\"\u003e\n\u003cli\u003eBrand: Tripp Lite by Eaton\u003c\/li\u003e\n\u003cli\u003eProduct Type: Line-interactive UPS\u003c\/li\u003e\n\u003cli\u003eManufacturer Part Number: SMX3000XLRT2UA\u003c\/li\u003e\n\u003cli\u003eInput Voltage: 230 V AC\u003c\/li\u003e\n\u003cli\u003eForm Factor: Rack\/Tower\u003c\/li\u003e\n\u003cli\u003eWaveform Type: Sine Wave\u003c\/li\u003e\n\u003cli\u003eRack Height: 2U\u003c\/li\u003e\n\u003cli\u003ePlug\/Connector Type: IEC 60320 C20\u003c\/li\u003e\n\u003cli\u003eProduct Family: SmartPro\u003c\/li\u003e\n\u003cli\u003eBackup\/Run Time (Half Load): 11.10 Minute\u003c\/li\u003e\n\u003cli\u003eBackup\/Run Time (Full Load): 3.90 Minute\u003c\/li\u003e\n\u003cli\u003eLoad Capacity: 3 kVA\/2.70 kW\u003c\/li\u003e\n\u003cbr\u003eMarketing Information: \u003cb\u003e3kVA\/3kW\/208V Battery Backup for Distributed IT, Telecom or Enterprise Deployments\u003c\/b\u003e\u003cp\u003eThe SMX3000XLRT2UA provides reliable battery backup and AC power protection for connected devices against blackouts, brownouts, surges and line noise. Unity power factor ensures the most watts possible at each power rating, so you can connect more equipment. Pure sine wave power and unity power factor, even when on battery, means this SmartPro ® UPS can be used with sensitive IT equipment, including servers, VoIP phones, data storage and PoE switches. Even if the battery is depleted, the UPS will automatically restart when the power comes back on after an extended outage.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eReliable, Expandable Battery Backup Keeps You Operational Through Power Outages\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Extra runtime is available by connecting up to four optional extended battery modules (BP72VRM2U, sold separately).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOutlets Protect Your Connected Components\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eEight C13 and two C19 outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Five outlets are grouped into two load banks that let you shed non-critical loads to extend runtime for critical loads. Front and rear cooling fans help protect equipment from overheating.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOptional LX Platform Network Management Card Allows Remote Access 24\/7\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIntuitive Front-Panel Interface for Convenient UPS Operation and Monitoring\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe two-line front-panel LCD monitoring screen features 10 selectable screens that allow quick access to a wide range of detailed UPS and site power information. LEDs show UPS status: a green light means utility power is on, an orange light means the UPS is in battery mode and a red light indicates an active alarm or fault. The control panel rotates to accommodate both rack-mount and tower configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAutomatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eAVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts. The SMX3000XLRT2UA maintains regulated 208V nominal output during brownouts and overvoltages from 160V to 294V while keeping the battery fully charged and ready to take over in case of power failure.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePremium Protection from EMI\/RFI Line Noise Helps Your Equipment Perform Better\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThis UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI\/RFI filtering also helps your connected components perform better and last longer.\u003c\/p\u003e\n\u003c\/ul\u003e\u003cdiv class=\"desc\"\u003eProduct Specifications:\u003cbr\u003e\u003cdiv style=\"display:block;\"\u003eProduct Features:\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth\u003ePRODUCT SPECIFICATIONS\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003cli\u003eManufacturer:Eaton Corporation\u003c\/li\u003e\n\u003cli\u003eManufacturer Part Number:SMX3000XLRT2UA\u003c\/li\u003e\n\u003cli\u003eManufacturer Website Address:https:\/\/tripplite.eaton.com\/\u003c\/li\u003e\n\u003cli\u003eBrand Name:Tripp Lite by Eaton\u003c\/li\u003e\n\u003cli\u003eProduct Line:SmartPro\u003c\/li\u003e\n\u003cli\u003eProduct Model:SMX3000XLRT2UA\u003c\/li\u003e\n\u003cli\u003eProduct Name:SMX3000XLRT2UA UPS System\u003c\/li\u003e\n\u003cbr\u003eMarketing Information:\u003cb\u003e3kVA\/3kW\/208V Battery Backup for Distributed IT, Telecom or Enterprise Deployments\u003c\/b\u003e\u003cp\u003eThe SMX3000XLRT2UA provides reliable battery backup and AC power protection for connected devices against blackouts, brownouts, surges and line noise. Unity power factor ensures the most watts possible at each power rating, so you can connect more equipment. Pure sine wave power and unity power factor, even when on battery, means this SmartPro ® UPS can be used with sensitive IT equipment, including servers, VoIP phones, data storage and PoE switches. Even if the battery is depleted, the UPS will automatically restart when the power comes back on after an extended outage.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eReliable, Expandable Battery Backup Keeps You Operational Through Power Outages\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Extra runtime is available by connecting up to four optional extended battery modules (BP72VRM2U, sold separately).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOutlets Protect Your Connected Components\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eEight C13 and two C19 outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Five outlets are grouped into two load banks that let you shed non-critical loads to extend runtime for critical loads. Front and rear cooling fans help protect equipment from overheating.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eOptional LX Platform Network Management Card Allows Remote Access 24\/7\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIntuitive Front-Panel Interface for Convenient UPS Operation and Monitoring\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe two-line front-panel LCD monitoring screen features 10 selectable screens that allow quick access to a wide range of detailed UPS and site power information. LEDs show UPS status: a green light means utility power is on, an orange light means the UPS is in battery mode and a red light indicates an active alarm or fault. The control panel rotates to accommodate both rack-mount and tower configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAutomatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eAVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts. The SMX3000XLRT2UA maintains regulated 208V nominal output during brownouts and overvoltages from 160V to 294V while keeping the battery fully charged and ready to take over in case of power failure.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePremium Protection from EMI\/RFI Line Noise Helps Your Equipment Perform Better\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThis UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI\/RFI filtering also helps your connected components perform better and last longer.\u003c\/p\u003e\n\u003cbr\u003e\u003ctr\u003e\n\u003ctd\u003ePlug\/Connector Type\u003c\/td\u003e\n\u003ctd\u003eIEC 60320 C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceptacle Type\u003c\/td\u003e\n\u003ctd\u003e\u003cul\u003e\n\u003cli\u003eIEC 60320 C13\u003c\/li\u003e\n\u003cli\u003eIEC 60320 C19\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceptacle Detail\u003c\/td\u003e\n\u003ctd\u003e\u003cul\u003e\n\u003cli\u003e8 x IEC 60320 C13\u003c\/li\u003e\n\u003cli\u003e1 x IEC 60320 C19\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Type\u003c\/td\u003e\n\u003ctd\u003e\u003cul\u003e\n\u003cli\u003eBrownout\u003c\/li\u003e\n\u003cli\u003eOver Voltage\u003c\/li\u003e\n\u003cli\u003eUnder Voltage\u003c\/li\u003e\n\u003cli\u003eEMI \/ RFI\u003c\/li\u003e\n\u003cli\u003eBlack Out\u003c\/li\u003e\n\u003cli\u003eSurge\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power OFF\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Capacity (VA)\u003c\/td\u003e\n\u003ctd\u003e3 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Capacity (Watt)\u003c\/td\u003e\n\u003ctd\u003e2.70 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e14.10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform Type\u003c\/td\u003e\n\u003ctd\u003eSine Wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Energy Rating\u003c\/td\u003e\n\u003ctd\u003e350 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management\u003c\/td\u003e\n\u003ctd\u003eSNMP Manageable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm\u003c\/td\u003e\n\u003ctd\u003e\u003cul\u003e\n\u003cli\u003ePower Failure\u003c\/li\u003e\n\u003cli\u003eLow Battery\u003c\/li\u003e\n\u003cli\u003eOverload\u003c\/li\u003e\n\u003cli\u003eUPS Fault\u003c\/li\u003e\n\u003cli\u003eRemote Shutdown\u003c\/li\u003e\n\u003cli\u003eUPS StartUp\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eFront panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Port\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup\/Run Time (Full Load)\u003c\/td\u003e\n\u003ctd\u003e3.90 Minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup\/Run Time (Half Load)\u003c\/td\u003e\n\u003ctd\u003e11.10 Minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Battery Recharge Time\u003c\/td\u003e\n\u003ctd\u003e5 Hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swappable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e104 °F (40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e158 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e3.50\" (88.90 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e17.50\" (444.50 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e19.50\" (495.30 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Height\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eRack\/Tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (Approximate)\u003c\/td\u003e\n\u003ctd\u003e62.80 lb (28485.60 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003e\u003cul\u003e\n\u003cli\u003eSMX3000XLRT2UA UPS System\u003c\/li\u003e\n\u003cli\u003ePowerAlert Software CD\u003c\/li\u003e\n\u003cli\u003e4 Post Rackmount Installation Kit\u003c\/li\u003e\n\u003cli\u003e3 x C13\/C14 Power Cables\u003c\/li\u003e\n\u003cli\u003eInstruction Manual\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003cli\u003eDB9 Cable\u003c\/li\u003e\n\u003cli\u003eEPO Cable\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications \u0026amp; Standards\u003c\/td\u003e\n\u003ctd\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eIEC 62040-1\u003c\/li\u003e\n\u003cli\u003eIEC 62040-2 Class A EMI\u003c\/li\u003e\n\u003cli\u003eGOST\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Included\u003c\/td\u003e\n\u003ctd\u003ePowerAlert Monitoring Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmentally Friendly\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Compliance\u003c\/td\u003e\n\u003ctd\u003eRestriction of Hazardous Substances (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLimited Warranty\u003c\/td\u003e\n\u003ctd\u003e2 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Tripp Lite","offers":[{"title":"Default Title","offer_id":48160577618166,"sku":null,"price":3396.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0668\/6067\/9414\/files\/1025883721_dfaa85aa-51b0-4d85-a370-195ce90d3280.jpg?v=1745264443","url":"https:\/\/upsplusbattery.ca\/products\/tripp-lite-smx3000xlrt2ua-3kva","provider":"UPSPLUSBATTERY","version":"1.0","type":"link"}