Xtreme Power 120V UPS Systems
Xtreme Power Conversion 120 V single-phase UPS — J60 and A60 standby, S71 line-interactive, P80 sinewave, T91 online, P91 / P91 Li online, J90 lithium 1U. 350 VA to 3 kVA on NEMA 5-15P / 5-20P / L5-30P plugs.
- Ships from Canada
- Canadian shipping
- Manufacturer warranty
Xtreme Power 120V UPS Systems catalogue
Xtreme Power T91-2000 2,000VA / 1,930W 120V Online UPS | Canada | UPSPLUSBATTERY
- Watts
- 1930
Xtreme Power T91-2000V2 2,000VA / 1,930W 120V Online UPS | Canada | UPSPLUSBATTERY
- Watts
- 1930
Xtreme Power P80-2200 2,200VA / 2,000W 120V Line-Interactive UPS | Canada | UPSPLUSBATTERY
- VA
- 2200
- Watts
- 2000
- Form
- Tower/Rack Convertible
- Topology
- Line-Interactive
Xtreme Power P80g-3000 3,000VA / 2,700W Line-Interactive UPS | Canada | UPSPLUSBATTERY
- VA
- 3000
- Watts
- 2700
- Form
- Tower/Rack Convertible
- Topology
- Line-Interactive
Xtreme Power P80-3000V2 3,000VA / 2,700W 120V Line-Interactive UPS | Canada | UPSPLUSBATTERY
- VA
- 3000
- Watts
- 2700
- Form
- Tower/Rack Convertible
- Topology
- Line-Interactive
Xtreme Power P80-3000 3,000VA / 2,700W 120V Line-Interactive UPS | Canada | UPSPLUSBATTERY
- VA
- 3000
- Watts
- 2700
- Form
- Tower/Rack Convertible
- Topology
- Line-Interactive
Xtreme Power P91-2000 2,000VA / 1,930W 120V Online UPS | Canada | UPSPLUSBATTERY
- VA
- 2000
- Watts
- 1930
- Form
- Tower/Rack Convertible
- Topology
- Online Double-Conversion
- Outlets
- 8× NEMA 5-15/20R
Xtreme Power T91-3000 3,000VA / 2,880W 120V Online UPS | Canada | UPSPLUSBATTERY
- Watts
- 2880
Xtreme Power J90-1KLiD 1,000VA / 900W 120V Lithium-Ion UPS | Canada | UPSPLUSBATTERY
- Watts
- 900
Xtreme Power P91-1.5KLi 1,500VA / 1,350W 120V Lithium-Ion Online UPS | Canada | UPSPLUSBATTERY
- VA
- 1500
- Watts
- 1350
- Form
- Tower/Rack Convertible
- Topology
- Online Double-Conversion
Xtreme Power P91-3000 3,000VA / 2,880W 120V Online UPS | Canada | UPSPLUSBATTERY
- VA
- 3000
- Watts
- 2880
- Form
- Tower/Rack Convertible
- Topology
- Online Double-Conversion
- Outlets
- 1× NEMA L5-30R,6× NEMA 5-15/20R
Xtreme Power J90-1.5KLiD 1,500VA / 1,350W 120V Lithium-Ion UPS | Canada | UPSPLUSBATTERY
- Watts
- 1350
Xtreme Power P80g-5000 5,000VA / 4,500W Line-Interactive UPS | Canada | UPSPLUSBATTERY
- VA
- 5000
- Watts
- 4500
- Form
- Tower/Rack Convertible
- Topology
- Line-Interactive
Xtreme Power P91-2KLi 2,000VA / 1,800W 120V Lithium-Ion Online UPS | Canada | UPSPLUSBATTERY
- VA
- 2000
- Watts
- 1800
- Form
- Tower/Rack Convertible
- Topology
- Online Double-Conversion
Xtreme Power J90-2KLiD 2,000VA / 1,800W 120V Lithium-Ion UPS | Canada | UPSPLUSBATTERY
- Watts
- 1800
Xtreme Power P91-3kLi 3,000VA / 2,700W 120V Lithium-Ion UPS | Canada | UPSPLUSBATTERY
- VA
- 3000
- Watts
- 2700
- Form
- Tower/Rack Convertible
- Topology
- Online Double-Conversion
Xtreme Power J90-3KLiD 3,000VA / 2,700W 120V Lithium-Ion UPS | Canada | UPSPLUSBATTERY
- Watts
- 2700
About Xtreme Power 120V UPS Systems
What is a 120 V UPS?
120 V single-phase is the default commercial and residential receptacle voltage across Canada. Almost all small-to-mid commercial UPS deployments — workstation, point-of-sale, server room, branch IT, network closet, edge compute — run 120 V on NEMA 5-15P (15 A), NEMA 5-20P (20 A), or NEMA L5-30P (locking 30 A) plugs. Step up to 208/230 V only when load exceeds the practical 120 V range or when the site already runs 208 V three-phase distribution.
UPSPLUSBATTERY.CA stocks the full XPC 120 V range across all topologies. For 208/230 V higher-power deployments see XPC 208/230 V UPS. For full XPC catalog see Xtreme Power Conversion.
XPC 120 V models by topology
| Topology | Series | VA range | Plug | Use |
|---|---|---|---|---|
| Standby — Lithium | J60, J60C | 350 / 600 VA | 5-15P | Digital signage, kiosk, POS, edge networking |
| Standby — SLA | A60 | 550 / 850 VA | 5-15P | Workstation, small office |
| Line-interactive — Tower | S71 | 700 / 1000 / 1500 VA | 5-15P | Office, routers, switches |
| Line-interactive — Sinewave | P80 | 800 VA – 3 kVA | 5-15P / 5-20P | Server room, network closet |
| Online — Tower | T91 | 700 VA – 3 kVA | 5-15P / L5-20P / L5-30P | Lab, industrial, edge compute |
| Online — Rack/Tower SLA | P91 / P91c | 1 / 1.5 / 2 / 3 kVA | 5-15P / 5-20P / L5-30P | IT rack, edge data centre |
| Online — Rack/Tower Lithium | P91 Li | 1.5 / 2 / 3 kVA | 5-15P / 5-20P / L5-30P | Long-deployment, hot-ambient |
| Online — 1U Lithium | J90 | 1 / 1.5 / 2 / 3 kVA | 5-15P / 5-20P / L5-30P | Switched outlets, slim 1U |
For 230 V variants of the same families (J60i, J90i, P91g, P91g Li, T91i), see XPC 208/230 V UPS.
How to choose
Plug type matters
NEMA 5-15P (the standard 15 A wall outlet) tops out around 1500 VA continuous on a UPS — the breaker is the limiter. NEMA 5-20P (20 A, T-slot neutral) supports up to ~2200 VA. NEMA L5-30P (locking 30 A) needed for 3000 VA at 120 V. If site only has 5-15 receptacles, biggest practical UPS is ~1500 VA — for 3 kVA at 120 V either install a dedicated 30 A 120 V circuit OR step up to 208 V.
When to leave 120 V
Continuous load above ~2400 W. Higher-density rack with multiple servers in one cabinet. Three-phase distribution already present. Above 3 kVA, 208/230 V is more efficient (lower line current, lower I²R loss) and the standard receptacle is L6-30 — see XPC 208/230 V UPS.
Sizing
Add nameplate watts of all loads, multiply by 1.25 buffer, pick UPS whose watt rating exceeds. P91-1500 SLA delivers 1450 W; P91-1500 Li delivers 1350 W; J90-1.5KLi delivers 1350 W; T91-1500 delivers 1450 W. P80 0.9 PF — P80-3000 = 2700 W. S71 0.6 PF — S71-1500 = 900 W. Read UPS sizing guide.
Replacement batteries
SLA cartridges across A60, S71, P80, T91, P91 stocked as compatible aftermarket — same V, Ah, terminal, and connector spec as factory. 1-year UPSPLUSBATTERY warranty. Lithium packs (J60, J60C, J90, P91 Li) are factory XPC only. Browse XPC UPS replacement batteries.
Installation and warranty
5-15P / 5-20P plug-and-play. L5-30P needs dedicated 30 A 120 V circuit installed by licensed electrician per CSA. Warranty (USA and Canada) varies by series: A60 / S71 / P80 / T91 / P91 standard 3-year; J60 / J60C 5-year; J90 / J90i / P91 Li / P91g Li 6-year. Coordinated through our Canadian team. Shipped from our Canadian warehouse — see shipping policy for rates and timing. Replies within 1 business day.
FAQ
What's the biggest XPC UPS that runs on a normal wall outlet?
NEMA 5-15P maxes out around 1500 VA continuous. Above that you either need a 5-20P (20 A) or L5-30P (30 A) circuit installed.
120 V vs 208 V — which is better?
120 V is fine and cheap up to ~2.4 kW continuous. Above that, 208 V is more efficient (half the line current, quarter the I²R loss in the cord) and locking L6-30 receptacles are standard in rack PDUs. For a single 1U/2U server, 120 V wins on simplicity. For a full rack, 208 V wins on efficiency. XPC 208/230 V UPS.
Does 120 V XPC support PDU output?
Yes. P91 / J90 above 2200 VA include locking 5-20R or L5-30R outputs. XPDU rack PDU options pair with most XPC 120 V UPS for distribution to multiple devices.
Can I plug a 5-15P UPS into a 5-20R outlet?
Yes — 5-20R is mechanically compatible with both 5-15P and 5-20P. The 20 A rating just means more current available; it does not require a 5-20P UPS plug.
Lithium 120 V — which series?
J60 / J60C standby (350 / 600 VA), J90 1U online (1–3 kVA), P91 Li 2U online (1.5–3 kVA). LiFePO₄ chemistry on all. XPC lithium UPS.
Battery life?
SLA: 4–5 years climate-controlled. Lithium: up to 15 years rated by XPC. When to replace UPS battery.
Canadian warranty?
Yes — every XPC 120 V series carries factory warranty terms that explicitly cover USA and Canada. RMA does not require cross-border shipping. Shipped from our Canadian warehouse.
120V UPS systems for North American standard outlets — 5-15P, 5-20P, and L5-30P input.
Standard 120V UPS systems are the right choice when your loads run on regular wall outlets and your facility provides standard 120V/15A or 120V/20A circuits. Output receptacles match the input voltage — 5-15R for general loads or 5-20R for higher-current rack equipment.
What's in this collection
The Xtreme Power 120V catalogue covers 350VA to 5kVA across the J60, A60, S71, P80, P91, T91, and J90 series. Standby, line-interactive, online, and lithium topologies all available.
Canadian XPC 120 V single-phase from stock.
Our Canadian team has specified APC, Eaton, Tripp Lite, Vertiv, Mitsubishi, Toshiba, CyberPower, XPC, and Delta UPS for healthcare, data centres, and government. Enquiries answered in business hours.