CyberPower Smart App Sinewave PR-Series UPS Systems

CyberPower Smart App Sinewave UPS Systems

CyberPower's Smart App Sinewave (PR) series is a line of line-interactive, pure sine wave UPS systems spanning roughly 500VA to 5000VA in tower, 1U/2U rackmount, and rack/tower-convertible form factors.

CyberPower Smart App Sinewave UPS Systems catalogue

Showing 1-24 of 46

Not sure which one fits? Open the UPS Solutions Builder →

Comparison

Shop the CyberPower Smart App Sinewave UPS lineup, line-interactive UPS with sine-wave output, multi-segment load control, and remote management. Models include CyberPower PR750LCD3C, PR1500LCDSL, PR2200LCDSL, PR2200RTXL2UCN, PR2200RT2UCN, PR2200RTXL2UHVAN, PR3000LCDSL, PR3000RTXL2UACN, PR3000RTXL2UHVACN plus rack/tower convertible variants and international SKUs.

Smart App Sinewave highlights: pure sinewave output (compatible with active-PFC server PSUs), AVR, GreenPower UPS technology (94% efficiency), Multifunction LCD, optional RMCARD-205 SNMP/HTTP management. PR-prefix models target server racks and small data center deployments.

Need replacement battery? Most PR-series UPS use CyberPower RB1290X4 or RB1270X4 cartridge codes. Contact our service partner for Canada-wide CyberPower commissioning and runtime testing.

Buying several units? Need it configured? For several units or a purchase order, request a written quote. Reply within 1 business day.
Request a quote → 438-881-3363

About CyberPower Smart App Sinewave UPS Systems

Read more: CyberPower Smart App Sinewave UPS Systems

About the CyberPower Smart App Sinewave (PR) Series

The CyberPower Smart App Sinewave series, the PR family, is CyberPower's professional line of line-interactive UPS systems built for servers, network closets, point-of-sale, NAS, medical and other equipment that demands clean, regulated power. Every unit in the series delivers pure sine wave output on battery, making it safe for active PFC power supplies found in modern servers and workstations. The series sits above CyberPower's consumer (simulated sine wave) lines and below its true double-conversion online (OL/OLS) systems, giving you protected, regulated power in a line-interactive design.

This collection spans a wide capacity range, roughly 500VA / 400W up to 5000VA / 5000W, in mini-tower, 1U and 2U rackmount, and rack/tower-convertible form factors.

Models in the PR Series

A representative selection from the range is below; see the full list of models in this collection for every variant, capacity and form factor.

ModelVA / WTopologyForm factorRuntime ½ / fullOutlets
PR500LCDRT1U500VA / 400WLine-InteractiveTower/Rack Convertible12.0 / 3.0 minNot listed
PR750RT2UC750VA / 750WLine-InteractiveTower/Rack Convertible19.0 / 7.5 min8 × NEMA 5-15R
PR1000LCD1000VA / 1000WLine-InteractiveTower10.5 / 3.1 min8 × NEMA 5-15R
PR1500RT2UC1500VA / 1500WLine-InteractiveRackmount 2U18.2 / 6.5 min8 × NEMA 5-15R
PRL1500RT2UC1500VA / 1500WLine-InteractiveTower/Rack Convertible18.7 / 8.7 min8 × NEMA 5-15R
PR2200RT2UC2200VA / 2200WLine-InteractiveRackmount 2U11.8 / 3.2 min8 × NEMA 5-20R
PR3000RTXL2UCN3000VA / 3000WLine-InteractiveTower/Rack Convertible7.0 / 1.7 min8 × NEMA 5-20R; 1 × NEMA L5-30R
PR5000RTXL2UC5000VA / 5000WLine-InteractiveRackmount 2U8.3 / 1.7 min1 × NEMA L6-20R; 1 × NEMA L6-30R

How to Choose

Size by watts, not just VA. Add up the wattage of everything you intend to protect and pick a model whose watt rating comfortably exceeds that load (aim to load to about 60 to 80% so you keep runtime headroom). VA is the apparent-power figure; watts is the real-power limit your equipment actually draws, and on most PR-series units the VA and W ratings are equal or close, so watts is the figure to size against.

Set a runtime expectation. The runtime columns above show approximate minutes at half load and full load. If you need more, look for models flagged as extended-runtime capable: most of the rack/tower units in this series accept external battery packs (EBM) to extend backup time well beyond the internal battery.

Topology. Every model here is line-interactive with automatic voltage regulation (AVR), which corrects brownouts and surges without switching to battery, and produces a true sine wave when it does transfer. This is the right tier for servers and PFC power supplies. If your application requires zero-transfer power (large data centre or sensitive lab loads), consider a true online/double-conversion UPS instead.

Rack vs tower. Choose a mini-tower for a desk or floor-standing install, a 1U/2U rackmount for a server rack, or a Tower/Rack convertible model if you want the flexibility to mount it either way. Check the outlet types in the table against the plugs on your equipment (NEMA 5-15R/5-20R for standard gear, L5-30R/L6-xxR locking outlets on higher-capacity units).

Key Features of the PR Series

  • Pure sine wave output on battery, safe for active-PFC servers and workstations.
  • Line-interactive with AVR to ride through brownouts and overvoltage without draining the battery.
  • Multi-function LCD showing load, runtime, battery status and event data.
  • Network management ready (SNMP/serial/USB) with PowerPanel software for safe shutdown and monitoring.
  • Extended-runtime capable on most rack/tower models via external battery packs.
  • Tower, 1U/2U rack and convertible form factors across the range.

Warranty, Canadian Shipping & Support

PR-series units carry a manufacturer warranty (commonly 3 years, with selected PRL models at 5 years; see the individual product page for the exact term). All orders ship from Canada.

When the internal batteries eventually reach end of life, you do not need to replace the whole unit: see our CyberPower replacement battery collection for the matching RB-series cartridges, and browse the full CyberPower range for other UPS families and accessories.

Frequently Asked Questions

Is the PR series line-interactive or online? Every model in this collection is line-interactive with automatic voltage regulation and pure sine wave output. For zero-transfer double-conversion power, look at CyberPower's online (OL) series instead.

What size UPS do I need? Total the wattage of your connected equipment and choose a model whose watt rating exceeds it with headroom (around 60 to 80% loading). The runtime figures in the table are approximate at half and full load.

Can I extend the runtime? Yes: most rack/tower models in this series are extended-runtime capable and accept external battery packs to lengthen backup time.

Will it work with my server's power supply? Yes. The pure sine wave output is specifically suited to active-PFC power supplies used in modern servers and high-end workstations.

Can I rack-mount these? Many models are 1U or 2U rackmount, and several are Tower/Rack convertible so you can mount them horizontally in a rack or stand them vertically as a tower. Check the form factor column for each model.

UPSPLUSBATTERY is a Canadian supplier of CyberPower UPS systems. Model names and trademarks belong to their respective owners.

Manufacturer warranty on new UPS
Canadian specialists: 438-881-3363 · Contact us