CyberPower OL1000RTXL2U 1000 VA / 900 W Rack/Tower Online UPS 2U
- Power
- 1000 VA / 900 W
- Form
- Tower/Rack Convertible
- Outlets
- 8× NEMA 5-15R
CyberPower's Smart App Online (OL) series is a line of true online double-conversion, pure sine wave UPS systems spanning 750 VA / 750 W up to 10,000 VA / 10,000 W in rackmount (2U–5U+) and tower/rack convertible form factors.
Not sure which one fits? Open the UPS Solutions Builder →
We confirm price and freight before ordering.
We confirm price and freight before ordering.
We confirm price and freight before ordering.
We confirm price and freight before ordering.
We confirm price and freight before ordering.
We confirm price and freight before ordering.
Shop the CyberPower Smart App Online UPS lineup, double-conversion online UPS for production server racks, mid-tier data center loads, and high-availability network rooms. Models include CyberPower OL750RTHD, OL1KRTHD, OL1K5RTHD, OL2K2RTHD, OL3KRTHD, OL3000RTXL2UN, OL5KRTHD, OL5KRTHDL, OL5KSTF, OL6KRTHD, OL6KRTHDL plus matching extended battery modules (BPL series) and international variants.
Smart App Online highlights: double-conversion online topology (zero-transfer-time), pure sinewave output, 0.9 power factor, hot-swap batteries on most models, optional RMCARD-205 / RMCARD-303 SNMP management, GreenPower UPS Eco mode (up to 96% efficiency), tower/rack convertible chassis (most models), parallel redundancy support on OL5K and OL6K systems.
OL-class units are typical replacements for legacy APC SURT, Eaton 9PX, or Liebert GXT systems. Need installation, parallel commissioning, or load-bank verification? Contact our service partner for Canada-wide CyberPower service.
The CyberPower Smart App Online (OL) series is a family of true online double-conversion uninterruptible power supplies built for the loads that cannot tolerate a transfer gap or dirty input power: servers, network closets, storage arrays, VoIP and telecom gear, medical and lab instruments, and edge equipment running off generator or unstable utility power. Because the OL series continuously rebuilds the AC waveform, it delivers a clean pure sine wave output with effectively zero transfer time to battery. It sits above CyberPower's line-interactive families (such as the Smart App LCD/PR sinewave series) as the company's premium, always-on protection tier.
This collection spans 750 VA / 750 W up to 10,000 VA / 10,000 W in rack/tower chassis (2U on most models listed below, 4U on the OL8KRTHD and OL10KRTHD), so you can match the unit to anything from a single appliance up to a full rack. Every model in the series is extended-runtime capable, accepting external battery packs when you need to ride through longer outages.
Representative and notable models are shown below. See the full range further down this page for every configuration we stock.
| Model | VA / W | Topology | Form factor | Runtime ½ / full load | Outlets |
|---|---|---|---|---|---|
| OL750RTHD | 750 VA / 750 W | Online Double-Conversion | Rack/Tower 2U | 14.0 / 5.0 min | 8 × NEMA 5-15R |
| OL1000RTXL2U | 1000 VA / 900 W | Online Double-Conversion | Rack/Tower 2U | 21.0 / 8.0 min | 8 × NEMA 5-15R |
| OL1KRTHD | 1000 VA / 1000 W | Online Double-Conversion | Rack/Tower 2U | 12.0 / 3.8 min | 8 × NEMA 5-15R |
| OL1500RTXL2U | 1500 VA / 1350 W | Online Double-Conversion | Rack/Tower 2U | 12.5 / 4.0 min | 8 × NEMA 5-15R |
| OL2200RTXL2U | 2200 VA / 1800 W | Online Double-Conversion | Rack/Tower 2U | 21.0 / 8.0 min | 6 × NEMA 5-20R; 1 × NEMA L5-20R |
| OL3000RTXL2U | 3000 VA / 2700 W | Online Double-Conversion | Rack/Tower 2U | 12.5 / 4.0 min | 6 × NEMA 5-20R; 1 × NEMA L5-30R |
| OL3KRTHD | 3000 VA / 2700 W | Online Double-Conversion | Rack/Tower 2U | 8.5 / 2.7 min | 6 × NEMA 5-20R; 1 × NEMA L5-30R |
| OL5KRTHD | 5000 VA / 5000 W | Online Double-Conversion | Rack/Tower 2U | 7.9 / 3.1 min | 2 × NEMA L6-20R; 2 × NEMA L6-30R |
| OL6KRTHD | 6000 VA / 6000 W | Online Double-Conversion | Rack/Tower 2U | 6.2 / 2.4 min | 2 × NEMA L6-20R; 2 × NEMA L6-30R |
| OL8KRTHD | 8000 VA / 8000 W | Online Double-Conversion | Rack/Tower 4U | 11.0 / 3.8 min | 4 × NEMA L6-20R; 2 × NEMA L6-30R; hardwire |
| OL10KRTHD | 10000 VA / 10000 W | Online Double-Conversion | Rack/Tower 4U | 8.3 / 2.4 min | 4 × NEMA L6-20R; 2 × NEMA L6-30R; hardwire |
The full series also includes the OL1000RTXL2UN, OL1500RTXL2UN, OL2200RTXL2UN, OL3000RTXL2UN, OL3000RTXL2UHVN, OL1K5RTHD, OL2K2RTHD, OL5KRTHDL, OL6KRTHDL, OL8KRT and OL10KRT. Higher-capacity units (5 kVA and up, plus the HVN models) provide 208/240 VAC output for high-density and split-phase deployments.
Size by watts, not just VA. Your equipment's real draw is measured in watts. Add up the wattage of everything you'll plug in, then pick a model whose watt rating comfortably exceeds that total (aim to load the UPS to roughly 50 to 80% of its watt rating to leave headroom and extend battery life). VA is the apparent-power rating and is always equal to or higher than watts; on the OL series the two are close because online double-conversion units carry a high power factor; several models here are rated 1:1 (for example OL750RTHD at 750 VA / 750 W and the OL5K to OL10K units).
Set runtime expectations. The runtimes in the table are at the unit's internal battery. Half-load runtimes here range from roughly 6 to 21 minutes, and full-load runtimes from about 2.4 to 8 minutes, enough to ride through brief outages or trigger a graceful, automated shutdown. If you need to survive longer outages or run until a generator stabilizes, every model in this series is extended-runtime capable and accepts matching external battery packs.
Topology: why online matters. Unlike line-interactive UPS systems that switch to battery only when the input fails, an online double-conversion UPS continuously converts incoming AC to DC and back to a new AC sine wave. That means zero transfer time and regulated output through sags, surges, frequency drift and waveform distortion: the right choice for servers, storage, telecom and any sensitive or generator-fed load.
Rack or tower. The models listed here are rack/tower units: they mount in a rack (2U, or 4U for the OL8KRTHD and OL10KRTHD) or stand upright in a closet.
The CyberPower OL units in this collection carry a 3-year manufacturer warranty. All stock is CyberPower equipment and ships from Canada.
Already own a CyberPower OL unit and just need new batteries? See our matching CyberPower replacement battery collection for the correct cartridges and external battery packs. To explore the rest of the lineup, visit the CyberPower brand page.
Is the Smart App Online series a true online UPS?
Yes. Every model in this collection uses online double-conversion topology, which continuously rebuilds the AC waveform and delivers a pure sine wave output with zero transfer time to battery.
What size UPS do I need?
Total the wattage of the equipment you'll connect and choose a model whose watt rating exceeds that total with room to spare (loading to about 50 to 80% is ideal). This series runs from 750 W to 10,000 W.
Can I extend the runtime?
Yes. Every model here is extended-runtime capable and accepts matching external battery packs for longer backup.
Can these be rack-mounted?
Yes. The models listed here are rack/tower units that install in a rack (2U, or 4U for the OL8KRTHD and OL10KRTHD) or stand as a tower.
Do they support network monitoring?
Yes. The OL series supports network/SNMP cards and management software for remote monitoring, alerts and automated shutdown.
UPSPLUSBATTERY is a Canadian supplier of CyberPower UPS systems. Model names and trademarks belong to their respective owners.