Voltage Regulators & Transformers

Find UPS systems, replacement batteries and accessories for your equipment.

  • Ships from Canada
  • Canadian shipping
  • Manufacturer warranty

Voltage Regulators & Transformers catalogue

Showing 1-24 of 29

About Voltage Regulators & Transformers

Voltage regulators and transformers: clean, stable power in front of the load

Between the utility and the gear that cares, two devices do the electrical housekeeping. A step-down transformer converts 208 V or 240 V to 120 V so a single feed can serve both worlds. An isolation transformer breaks the electrical bond between source and load, killing ground noise and leakage paths. A voltage regulator holds the output steady while the input sags and swells. This collection holds all three, plus PDU-transformer combinations that distribute what they convert.

The families here: APC Smart-UPS SRT and Smart-UPS Ultra step-down transformers, the Tripp Lite SU6000XFMR2U, the Eaton 9PX transformer and 9355 isolation cabinets, and the Xtreme Power TXVR regulator line with XPD-IT PDU-transformer units.

Models at a glance

A representative selection. The full list is in the product grid below.

PartTypeRatingForm factorNotes
TXVR-5KB1XPC isolated voltage regulator5 kVA / 5 kWon requestTXVR series
TXVR-10KB1XPC isolated voltage regulator10 kVA / 10 kWon requestTXVR series
XPD-IT6KWXPC PDU with isolation transformer6 kVAon request208 V to 240/120 V
JX-200XPC isolation transformer200 Won request120 VAC, C14 inlet
SRT5KRMTFAPC step-down transformer5 kVARackmount 2USmart-UPS SRT
SRT10KRMTFAPC step-down transformer10 kVARackmount 4USmart-UPS SRT
SRTL5KRMTFAPC step-down transformer5 kVARackmountSmart-UPS Ultra
SRT5KTFAPC isolation step-down transformer5 kVATowerSmart-UPS SRT
SU6000XFMR2UTripp Lite step-down transformer6 kVA / 6 kWRackmount 2Uon request
9PXTFMR11Eaton step-down transformer10 kWRack/tower9PX

Ratings are the manufacturer figures from each part listing. Match the kVA to the load and the input voltage to the building feed before ordering.

How to choose

Convert, isolate or regulate? Convert when the voltage is wrong (208/240 V to 120 V): a step-down transformer. Isolate when noise or ground loops are the problem: an isolation transformer. Regulate when the line wanders but never fails: a voltage regulator. Many devices here do two of the three at once.

Size in kVA with headroom. Transformers do not like running at their ceiling. Take the load in volt-amperes, add 25 percent, and pick the next rating up.

Decide where it lives. The 2U and 4U rackmount units sit in the rack next to the UPS; tower and cabinet units live on the floor; the JX-200 tucks behind a compact UPS. Heat output follows the rating, so leave airflow.

PDU-transformers save a unit. The XPD-IT line converts and distributes in one chassis: 208 V in, isolated 120 V outlets out. For racks that need both conversion and outlet count, that is one less box.

Let the electrician land the feed. Higher-kVA units are hardwired. Plan the breaker, the conductor size and the bypass together.

Why regulate the power

  • Stable 120 V for sensitive gear fed from 208/240 V circuits
  • Isolation that breaks noise and ground-loop paths
  • Regulation that rides through sags the UPS would otherwise battery through
  • Rack, tower and PDU-combined formats
  • Ships from Canada.

Quotes, configuration and shipping

Send the load in volt-amperes, the input voltage and what the power problem actually looks like, and we match the device. Request a quote; multi-unit and cabinet configurations are quoted together. Ships from Canada.

Related: three-phase UPS systems and rack PDUs.

Frequently asked questions

Transformer or regulator?
A transformer changes voltage; a regulator corrects it continuously as the input moves. If the voltage is steady but wrong, transform. If it wanders, regulate.

Does an isolation transformer protect against surges?
It blocks common-mode noise and transients between primary and secondary, which helps, but it is not a surge protector; pair it with upstream protection.

Can I run a transformer at full rating all day?
It will run, but heat shortens life. The 25 percent headroom rule keeps the windings cool.

Why put the transformer in the rack?
Short heavy runs: the 2U and 4U units deliver 120 V where the servers are instead of pulling a separate circuit across the room.

Do these work with any UPS brand?
The transformers and regulators here feed standard voltages; the SRT and 9PX families are shaped for their own UPS lines. Ask us for a pairing check.

Isolated electronic voltage regulators and isolation transformers that condition and stabilize utility power for sensitive equipment, protecting against over/under-voltage, brownouts and electrical noise. Use ahead of or alongside a UPS for clean, regulated power.

Why buy from UPSPLUSBATTERY.CA
Still narrowing down

Talk to a Canadian UPS specialist.

Our Canadian team has specified APC, Eaton, Tripp Lite, Vertiv, Mitsubishi, Toshiba, CyberPower, XPC, and Delta UPS for healthcare, data centres, and government. Enquiries answered in business hours.