What is a battery pack / EBP?

An External Battery Pack (EBP) is a chassis of additional UPS-rated batteries that connects to a compatible UPS via a rear bus cable or terminal connection. The UPS treats the EBP as additional internal capacity — runtime extends in proportion to total Ah added. Each EBP roughly doubles runtime at a given load. Multiple EBPs stack on most XPC P91 and T91 SKUs to extend ride-through to half an hour or more, and TX91-BP960 packs scale TX91 isolated UPS to as much as 8 hours of ride-through per XPC's published runtime curves.

UPSPLUSBATTERY.CA stocks the XPC EBP range matched to each compatible UPS family. For internal-cartridge replacements (not extension) see XPC UPS replacement batteries. For full XPC catalog see Xtreme Power Conversion.

XPC battery pack range

PackCompatible UPSChemistryConfiguration
P90-BP48P80-1500 / 2000SLA2-string
P90-BP72P80-2200 / 3000, P80g-3000, P91-3000SLA2-string
P80-BP72XP80g-5000SLA — high capacity(12) 12 V 580 W
P91-BP36P91 / P91g-1500SLA2-string
P91-BP36EP91 / P91g-1500SLA — extended4-string
P91-BP48P91 / P91g-2000SLA2-string
P91-BP72P91-3000, P91g-3000SLA2-string
BPXR2U240AP91-5K / 6K / 10KSLA — 2U hot-swap(20) 12 V 5 Ah
BPXR3U240AP91-5K / 6K / 10KSLA — 3U hot-swap(20) 12 V 580 W
T91-BP36AT91-1000 / 1500SLA2-string — up to 7 BP per UPS
T91-BP72AT91-2000, T91i-2000, T91-3000SLA2-string — up to 7 BP per UPS
J90-EBP48J90-2KLi, J90-3KLi (and J90i)LiFePO₄ Lithium20 Ah, 48 V DC
TX91-BP960-1 / 2 / 3TX91 3.8 / 5 / 6 / 10 kVASLA1, 2, or 3 strings; up to 3 packs per UPS
M90S-BMXRV2M90S split-phaseSLA — modular2 sleeves of (8) 12 V 580 W
M90-BC battery cabinetM90LU / M90U / M90U-80 / M90U-140SLA — modularUp to 32 modules, 8 strings
X90-BC battery cabinetX90-1S / X90-2SSLA — modularString-configurable

How to choose

How much runtime do I need?

Site with generator: 5–10 minutes covers genset start and stabilization. Site without generator: 15–30 minutes for graceful shutdown and replication failover. For TX91 isolated UPS: up to 8 hours ride-through is achievable with TX91-BP960-3 packs across the chassis. Past ~30 minutes the math typically tilts toward genset over batteries. Use the runtime calculator for ballpark estimates.

Stack count

P91 1–3 kVA: typically 1–2 packs. P91 5 / 6 / 10 kVA: BPXR packs hot-swappable. T91 1–3 kVA: up to 7 BP per UPS. TX91 3.8–10 kVA: up to 3 BP-960 packs per UPS. J90-2K / 3K Li: J90-EBP48 lithium for matched lithium runtime. M90 / X90: site-engineered string sizing in matching battery cabinets.

Compatibility

Every EBP is matched to a specific UPS series and VA range — connector, voltage, and battery configuration are all model-specific. P91-BP36 does not work on P91-3000. P90-BP48 does not work on P80-2200. Confirm UPS model before ordering EBP. Our team can verify compatibility — replies within 1 business day.

SLA vs lithium EBP

P91-BP, T91-BP, BPXR, P80-BP, TX91-BP960, M90-BC, X90-BC: SLA. Lower sticker, 4–5 year battery service life, replace alongside the UPS internal cartridge at end-of-life. J90-EBP48 lithium for J90: matched LiFePO₄, 15-year service life, eliminates one full battery replacement over deployment. Match chemistry to UPS — never mix SLA EBP on a lithium UPS or vice versa.

Internal cartridges and disclosure

SLA EBPs in stock are compatible aftermarket built to identical V, Ah, terminal, and connector spec as factory packs. 1-year UPSPLUSBATTERY warranty. Lithium EBPs (J90-EBP48 and Li90 modules) are factory XPC only — UPSPLUSBATTERY.CA does not stock aftermarket lithium because BMS firmware must match the UPS at manufacture. For internal cartridge replacements rather than runtime extension, see XPC UPS replacement batteries.

Installation and warranty

EBPs connect via rear bus cable to the UPS. Hot-pluggable on most P91, BPXR, T91, TX91, M90, X90 packs — connect to running UPS without powering down protected load. Tower-stand or rack-rail kit included on rack/tower packs. New SLA EBPs ship with manufacturer warranty (terms vary by series). J90-EBP48 lithium ships with 6-year warranty. Optional 5-year extended factory warranty available on most BP series (P90L5SPBP, T915SPBP, P91L5SPBP, P90L5SPBP2, T9SPBP2/4/6). Coordinated through our Canadian team. Shipped from our Canadian warehouse — see shipping policy for rates and timing. Replies within 1 business day.

FAQ

How much does one EBP extend runtime?

Roughly doubles runtime at a given load — proportional to total Ah added. P91-1500 with stock battery + P91-BP36: ~2× stock runtime. Add a second BP — quadruples. Past 2× returns diminish on smaller chassis because UPS internal voltage regulator and inverter limits become binding before pure capacity.

Can I stack multiple EBPs?

P91 1–3 kVA: typically 1–2 BP per UPS. T91: up to 7 BP per UPS — major runtime extension. P91 5–10 kVA: BPXR packs as needed. TX91: up to 3 BP-960 packs. J90 lithium: 1× J90-EBP48 supported. Confirm by model.

Hot-plug an EBP onto a running UPS?

Yes on most P91, T91, TX91, M90, X90 packs — designed for live attach via rear bus cable or pluggable connector. UPS detects the additional capacity automatically.

Mix SLA and lithium EBP?

No. Never mix. Chemistry, voltage, charge curve, and BMS firmware are all model-specific. Match SLA EBP to SLA UPS, lithium EBP (J90-EBP48) to lithium UPS (J90 / J90i 2K / 3K).

Replace an EBP cartridge?

Yes for SLA — internal SLA cartridges in P91-BP, BPXR, T91-BP, TX91-BP960, M90 / X90 modules replace via tool-less front-access door, just like the main UPS cartridge. How to install UPS battery. Lithium J90-EBP48 is sealed and replaced as a complete unit when the BMS reports end-of-life.

Do I need an electrician to add an EBP?

No — EBP connects to UPS via supplied bus cable or pluggable connector. The UPS itself is what's plugged into wall power (or hard-wired). As long as the UPS circuit is sized for the load, adding EBPs does not require electrical work.

Canadian warranty?

Yes — XPC EBP factory warranty terms explicitly cover USA and Canada. UPSPLUSBATTERY 1-year warranty on aftermarket SLA replacement cells. RMA does not require cross-border shipping. Shipped from our Canadian warehouse.

OEM extended runtime battery packs for Xtreme Power Conversion UPS systems.

When the standard 5–15 minute internal runtime isn't enough — for example, when you need to ride out a 30-minute brownout or have time for a graceful 20-minute server shutdown — extended runtime battery packs give you the buffer you need. All XPC battery packs plug directly into compatible UPS units with no rewiring required, and most are hot-swappable.

What's in this collection

Genuine Xtreme Power battery packs covering the P80, P90, P91, J90 (lithium), TX91, and T91 series. Each pack is matched to its parent UPS family — check the product page for the compatible UPS list before ordering.

Why buy from UPSPLUSBATTERY.CA
Need More XPC Runtime?

Canadian XPC extended battery packs from stock.

Our Canadian team has specified APC, Eaton, Tripp Lite, Vertiv, Mitsubishi, Toshiba, CyberPower, XPC, and Delta UPS for healthcare, data centres, and government. Enquiries answered in business hours.