APC by Schneider Electric Galaxy VX 1500kVA N+1 Redundant UPS 400V, Start up 5x8 - GVX1750K1500HS
- Watts
- 1500000
- Form
- Tower
- Topology
- Online Double-Conversion
The APC by Schneider Electric Galaxy VX is a three-phase, online double-conversion UPS series with pure sine-wave output, spanning 500 kVA to 1500 kVA in tower form for large data centres and critical facilities. Genuine APC by Schneider Electric, shipped from our Canadian warehouse.
The APC by Schneider Electric Galaxy VX is a three-phase, online double-conversion uninterruptible power supply built for large data centres, industrial sites, and mission-critical facilities. Every unit in this series delivers a pure sine-wave output through full online double-conversion, isolating your load from utility disturbances with zero transfer time. The Galaxy VX sits at the top of the APC three-phase lineup, scaling from 500 kVA up to 1500 kVA in a tower (free-standing) form factor, with single-module, N+1 redundant, and field-scalable configurations available. If you are sizing a centralized UPS for a facility rather than a single rack, this is the series to evaluate.
All models below are online double-conversion, pure sine wave, tower form factor, with 400 V AC output (several also support 380 V / 415 V) and are extended-runtime capable. Power ratings are shown in kVA as carried by each model. This is a representative selection; see the full range below.
| Model | Rating (kVA) | Topology | Form factor | Output | Configuration |
|---|---|---|---|---|---|
| GVX500K500HS | 500 kVA | Online double-conversion | Tower | 400 V | Single module |
| GVX500K750HS | 500 kVA, scalable to 750 kVA | Online double-conversion | Tower | 400 V | Scalable |
| GVX500K1000HS | 500 kVA, scalable to 1000 kVA | Online double-conversion | Tower | 400 V | Scalable |
| GVX750K500HS | 500 kVA | Online double-conversion | Tower | 400 V | N+1 redundant |
| GVX625K625HS | 625 kVA | Online double-conversion | Tower | 400 V | Single module |
| GVX750K750HS | 750 kVA | Online double-conversion | Tower | 400 V | Single module |
| GVX750K1000HS | 750 kVA, scalable to 1000 kVA | Online double-conversion | Tower | 400 V | Scalable |
| GVX1000K1000HS | 1000 kVA | Online double-conversion | Tower | 400 V | Single module |
| GVX1250K1250HS | 1250 kVA | Online double-conversion | Tower | 400 V | Single module |
| GVX1500K1500HS | 1500 kVA | Online double-conversion | Tower | 400 V | Single module |
The full range below also includes additional scalable and N+1 redundant variants (for example GVX1000K1500HS, GVX1250K1500HS, GVX1500K1250HS and GVX1750K1500HS) that let you start at a base rating and grow capacity or add redundancy without replacing the frame.
Size by kVA and kW. A UPS is rated in both apparent power (kVA) and real power (kW). Add up the load of the equipment the UPS must support, include headroom for growth, and choose a rating at or above that figure. Because the Galaxy VX is a centralized facility-class system, sizing is usually done with your electrical engineer or integrator against the full connected load.
Single vs. scalable vs. N+1. Single-module units (for example GVX500K500HS) suit a fixed, known load. Scalable units (for example GVX500K750HS) let you license additional capacity later inside the same frame. N+1 redundant configurations add a spare power module so the system keeps supporting full load even if one module is offline for service.
Topology. The Galaxy VX is exclusively online double-conversion. The load is always fed from the inverter, so there is no transfer time on a utility failure and the output is conditioned against sags, surges, and frequency variation. This is the appropriate topology for data centres and other loads that cannot tolerate any break in clean power.
Runtime. Runtime depends on the external battery cabinets paired with the UPS rather than internal batteries. Every model in this series is extended-runtime capable, so battery autonomy is engineered to your facility's ride-through requirement.
Form factor. All Galaxy VX units are free-standing tower (floor-mount) systems intended for a dedicated electrical or UPS room, not rack mounting.
These are genuine APC by Schneider Electric Galaxy VX systems. UPSPLUSBATTERY is an authorized Canadian reseller and ships from our Canadian warehouse, so you order in CAD and avoid cross-border import friction. Warranty is provided per APC's standard terms for the Galaxy VX line; our team can confirm the current coverage and available start-up service for the exact model you are configuring.
Already running a Galaxy VX and need cells rather than a new system? See our APC Galaxy VX replacement batteries, and browse the full APC UPS systems range for other APC families.
What is the power range of the Galaxy VX series?
The Galaxy VX models in this collection span 500 kVA up to 1500 kVA, available as single-module, field-scalable, and N+1 redundant configurations.
Is the Galaxy VX online double-conversion?
Yes. Every Galaxy VX unit is online double-conversion with pure sine-wave output, so the load is always fed from the inverter with no transfer time on a power failure.
Does the Galaxy VX include batteries for runtime?
Runtime is provided by external battery cabinets sized to your facility. All models are extended-runtime capable, so autonomy is engineered to your ride-through target rather than fixed.
Is this a rack-mount UPS?
No. The Galaxy VX is a free-standing tower (floor-mount) system designed for a dedicated electrical or UPS room.
What output voltage does it provide?
The series provides 400 V AC three-phase output, with several models also supporting 380 V and 415 V.
UPSPLUSBATTERY is an authorized Canadian reseller of genuine APC by Schneider Electric UPS systems; APC, Schneider Electric, Galaxy VX, and model names are trademarks of their respective owners.
Shop the APC by Schneider Electric Galaxy VX lineup — the mega-capacity 3-phase double-conversion online UPS designed for hyperscale data centers, large hospital campuses, and 250kVA+ commercial deployments. Models include Galaxy VX 750kVA (GVX750K750HS, GVX1000K750HS) plus matching power and battery configurations.
Galaxy VX highlights: 250kVA-1500kVA capacity, 3-phase 400V hardwired input/output, transformer-less topology for higher efficiency (96-97%), N+1 redundancy support, parallel redundancy up to 4-unit configurations, internal/external maintenance bypass, optional EcoStruxure cloud monitoring, optional Lithium-Ion battery upgrades.
Galaxy VX requires factory-trained commissioning, coordinated site electrical capacity planning (400V service entrance, often dedicated transformer), proper cooling capacity, and trained operations staff. Contact GDF Technologies for Canada-wide enterprise APC service.
Our Canadian team has specified APC, Eaton, Tripp Lite, Vertiv, Mitsubishi, Toshiba, CyberPower, XPC, and Delta UPS for healthcare, data centres, and government. Enquiries answered in business hours.