Replacement battery cartridges and EBM packs for the original Emerson Liebert GXT Series UPS, the first-generation GXT online double-conversion UPS still in service across legacy data centers, lab environments, and broadcast facilities. Models supported include GXT-1000MT, GXT-1000MT-120, GXT-1000RT-120, GXT-1000RTE-120, GXT-1000RX-120, GXT-1500RT-120, GXT-2000RT-120, GXT-2100RT-60, GXT-10000T-208, GXT-60000T-208 and matching battery extension packs (GXT-36VBATT, GXT-96VBATT).

Gen-1 GXT cartridges use 12V 7Ah SLA cells in fixed-string configurations. Most are not user-serviceable hot-swap: cartridge replacement requires putting the load on bypass. Always confirm the cartridge part number on your existing battery before ordering. Note: many Gen-1 GXT systems are 15+ years old and approaching end-of-service; consider migrating to current Vertiv GXT5 or Liebert PSI5 platforms.

Recommended swap window: 2-3 years on Gen-1 systems (older units typically run hot, plus the cells inside have 5-7 year shelf-age before swap). For Gen-1 GXT commissioning, bypass-mode battery swap, or migration planning to current Vertiv platforms contact our service partner for Canada-wide service.

About Vertiv Liebert GXT (Gen-1) Replacement Batteries

Read more: Vertiv Liebert GXT (Gen-1) Replacement Batteries

Replacement batteries for first-generation Liebert GXT UPS systems

This collection covers compatible replacement battery cartridges for the original (Gen-1) Emerson / Vertiv Liebert GXT family of double-conversion online UPS units. These were sold under both the Emerson Network Power and Liebert names, with model numbers in the GXT-1000, GXT-1500, GXT-2000, and larger GXT-T series, plus the matching battery packs such as GXT-36VBATT and GXT-96VBATT. As these units age, the internal batteries are the single most common part to fail and the part most often replaced.

Battery type and how it scales

The Gen-1 GXT line uses sealed lead-acid (SLA / VRLA) cells, almost always 12-volt blocks in the 7 to 7.2 Ah class, with some larger models using 9.0 Ah cells. A single UPS does not run on one 12V battery: the cells are wired in series into a string, so the total DC bus voltage scales with the model. Smaller 1000 VA units use a lower-voltage string, while larger rack/tower units stack more 12V blocks to reach 36V, 96V or higher. Because the cell count and arrangement differ by model, the right cartridge is defined by your exact unit, not by a single headline number.

Identify your battery by exact model

Do not order by appearance or by VA rating alone. Find the model number printed on the UPS rear or side label (for example, GXT-1000RT-120 or GXT-2000RT-120) and match it to the product in the grid below. Each product lists its compatible UPS model and the cell specification. If your label shows a variant suffix (RT, RX, MT, RTE, regional voltage codes), confirm it matches exactly before ordering: a 120V North American unit and a 230V international unit can look identical but take different packs.

OEM vs aftermarket

Vertiv sells factory battery cartridges under its OEM part numbers. The cartridges in this collection are compatible replacements matched on voltage, capacity, terminals and connectors, so they fit the same tray. Choose OEM where a warranty or service contract requires it.

Battery lifespan

SLA UPS batteries typically last 3 to 5 years in service. Heat is the dominant factor: as a rule of thumb, battery life is roughly halved for every 8°C of sustained temperature above 25°C (77°F). A UPS in a hot closet or a poorly ventilated rack will need batteries sooner than one in a climate-controlled room. Watch for a shrinking self-test runtime or a UPS battery-fault alarm as the signal to replace.

Replacement steps

  1. Confirm the exact model and order the matching cartridge.
  2. Check whether your specific unit supports hot-swap before you start. Hot-swap behaviour varies across the Gen-1 GXT line: some rack/tower models accept a front-bay cartridge while the UPS keeps protecting the load, while other units, including the compact mini-tower (MT) models in this collection, require opening a screwed battery door or compartment per the manual and are not tool-less hot-swap. When in doubt, treat the unit as non-hot-swap: power down and transfer the load before servicing.
  3. Release and slide out the old cartridge from the front bay, or open the battery compartment per the manual for your model.
  4. Insert the new cartridge, seat the connector fully, and secure the retaining bracket, bezel, or battery door.
  5. Let the UPS recharge fully, then run a self-test to confirm healthy runtime.
  6. Recycle the old SLA batteries through a proper lead-acid recycling channel: do not landfill them.

Frequently asked questions

How do I know which pack fits my UPS? Match the exact model number on your unit's label to the compatible model listed on each product. The product grid shows the cell voltage and Ah for each item.

Are these Vertiv batteries? No. They are compatible replacements matched on voltage, capacity, terminals and connectors.

How long will a new battery last? Plan for 3 to 5 years, shorter if the UPS runs hot. Keeping the ambient temperature near 25°C maximizes life.

Can I replace the battery while the UPS stays on? It depends on your exact model. Some Gen-1 GXT rack/tower units support hot-swap and let you change the cartridge while the load stays protected; others, including the mini-tower (MT) units, use a screwed battery door and are not designed for hot-swap. Check your unit's manual first, and if you are unsure, power down and transfer the load before servicing.

Where does it ship from? Orders ship from Canada.