APC Smart-UPS 1000 Replacement Batteries

APC Smart-UPS 1000VA Replacement Batteries

Replacement batteries for the APC Smart-UPS 1000 VA family. Across its generations (SU, SUA, SMC, SU-XL) these use a single 12 V, a 24 V, or a 48 V battery — so the right pack depends entirely on your exact model. Genuine APC and compatible aftermarket, shipped from our Canadian warehouse — send us your model and we'll confirm.

  • Ships from Canada
  • Canadian shipping
  • 1-year warranty

APC Smart-UPS 1000VA Replacement Batteries catalogue

Showing 1-12 of 12

About APC Smart-UPS 1000VA Replacement Batteries

APC Smart-UPS 1000 replacement batteries

The APC Smart-UPS 1000 VA family spans several generations — the legacy SU and SUA models, the SMC LCD models, and the extended-runtime SU-XL models. Their sealed lead-acid (VRLA) batteries wear out after about 3–5 years; a fresh pack restores full runtime. Because the battery differs significantly between generations, confirm your exact model before ordering.

For the full range see APC replacement batteries and APC Smart-UPS batteries.

Which battery does my Smart-UPS 1000 take?

The pack voltage depends on the generation: some models use a single 12 V battery, others a 24 V pack (two 12 V), and rack / XL models a 48 V pack (four 12 V). Capacity also varies (roughly 6–17 Ah). Because of this spread, match by your exact model number (e.g. SMC1000-2UC, SU1000RM2U, SU1000XLNET) — the VA rating alone is not enough.

How to identify the right battery

Read the model number on the rear or side label, or the front LCD. Select the matching battery below, or send us your model number and we'll confirm the correct pack — usually within 1 business day.

Genuine APC vs compatible aftermarket

Both restore full runtime. Genuine APC: OEM cartridge with a 2-year APC battery warranty. Compatible aftermarket: the same form factor and connector for your model, built from quality VRLA cells, typically 30–50 % less, with a 1-year UPSPLUSBATTERY warranty.

How long does it last?

3–5 years at 20–25 °C; heat roughly halves life for every ~8 °C above 25 °C. See when to replace a UPS battery.

How to replace

Smart-UPS batteries are hot-swappable on most models — the UPS keeps protecting the load:

  1. Confirm the correct pack for your exact model.
  2. Open the battery compartment (front bezel on tower; tray latch on rack).
  3. Disconnect the battery connector.
  4. Slide the old pack out and the new one in.
  5. Reconnect until it clicks and run a self-test.

See how to install a UPS battery.

FAQ

What voltage is the Smart-UPS 1000 battery?

It depends on the model — 12 V, 24 V or 48 V across the SU / SUA / SMC / XL generations. Match by exact model number.

I have an SMC1000 — is that the same as an SU1000?

No — different generations use different packs. Confirm against your exact model.

How often should I replace it?

Every 3–5 years; sooner in warm spaces.

APC® and Smart-UPS® are registered trademarks of Schneider Electric / APC. UPSPLUSBATTERY.ca is not affiliated with, endorsed by, or authorized by APC by Schneider Electric; aftermarket batteries are compatible replacements.

Replacement battery cartridges for APC Smart-UPS 1000VA series — the entry-level Smart-UPS line for desktop/SOHO server cabinets, network gear, and small workstation deployments. Models supported include SU1000, SU1000RM2U, SU1000RM3U, SUA1000RM1U, SUA1000RMI1U, SUA1000RM2U, SUA1000UXI, SUVS1000I, SU1000VS, SU1000XLNET, SU1000XLINET, SMC1000-2UC, SMC1000I-2U, SMT1000RM2UC, SMT1000I, S10BLK (AV Black 1000VA) plus SUA1000I and SUA1000ICH international variants.

Most Smart-UPS 1000VA cartridges use APC RBC6 (4-cell 12V 7Ah) for tower/rack-2U or RBC23 (4-cell 12V 9Ah) for rack-1U revisions — always confirm the cartridge code printed on your existing battery before ordering. The Smart-UPS 1000VA platform spans 3 generations: original Smart-UPS 1000 (SU1000), Smart-UPS 1000VA gen-2 (SUA1000), and Smart-UPS 1000VA LCD (SMT1000 / SMC1000).

Recommended swap interval: 3-5 years per IEEE 1188; rack-mount 1000VA units in production environments often run hotter and benefit from earlier replacement. Validate runtime before swap. For commissioning or runtime calibration on multi-unit deployments contact GDF Technologies for Canada-wide service.

Why buy from UPSPLUSBATTERY.CA
Still narrowing down

Talk to a Canadian UPS specialist.

Our Canadian team has specified APC, Eaton, Tripp Lite, Vertiv, Mitsubishi, Toshiba, CyberPower, XPC, and Delta UPS for healthcare, data centres, and government. Enquiries answered in business hours.