Eaton PW5119-1500i Battery Replacement Kit for Powerware
- Voltage
- 12
- Capacity
- 7.2 Ah
- Terminal
- Molex Connector
- Type
- Compatible Replacement
Replacement battery kits for the Eaton Powerware PW5119 UPS line. Battery configuration varies by model, so confirm your exact PW5119 model and the product grid below shows the matching voltage and amp-hour specs. All kits are shipped from our Canadian warehouse.
The Eaton Powerware PW5119 is a line-interactive UPS family built for servers, networking gear, and small server rooms. Like every UPS in this class, it stores energy in sealed lead-acid (SLA / VRLA) batteries that wear out and need periodic replacement to keep your runtime ratings intact. The kits in this collection are direct-fit replacements for the internal battery packs across the PW5119 range.
PW5119 units use sealed lead-acid cells, but the pack configuration is not the same across the line. Smaller models use a few 12V cells; larger and rack models string together multiple 6V or 12V blocks to reach the required DC bus voltage. Amp-hour capacity also changes with the model. Because of this, there is no single voltage/Ah spec for the whole series — the correct kit is determined by your exact model.
Find the model number on the front bezel or the rating label on the rear of the chassis (for example PW5119-1000i, PW5119-1500i, PW5119-2400i, or a rack -RM variant). Match that exact model to the product below. Each product page lists the voltage and amp-hours for that kit, and the grid on this page shows the specs per product so you can confirm the fit before you order.
You can replace PW5119 batteries with genuine Eaton OEM packs or with compatible aftermarket SLA kits. Aftermarket kits use cells of the same chemistry, voltage, capacity, and terminal type as the original, and are a lower-cost, drop-in alternative. The kits sold here are aftermarket compatible replacements, not Eaton-branded parts.
SLA UPS batteries typically last 3 to 5 years. Heat is the biggest factor: every roughly 8°C (about 15°F) of sustained temperature above 25°C (77°F) can cut battery life by about half. Keep the unit in a cool, ventilated spot and check the UPS self-test status periodically. If runtime has dropped noticeably or the UPS reports a battery fault, it is time to replace.
How do I know which kit fits my PW5119?
Match the exact model number printed on your unit to the matching product in the grid. Each product lists its voltage and amp-hours.
Can I replace the batteries myself?
Yes for most users. Power the unit down first and follow the steps above. If your specific model's manual documents a user-replaceable battery module, follow that procedure instead.
Are these the same as Eaton OEM batteries?
They are compatible aftermarket replacements that match the original cells in voltage, capacity, chemistry, and terminal type.
How long will the new batteries last?
Typically 3 to 5 years, shorter in hot environments. Heat above 25°C roughly halves life for every ~8°C increase.
Do I need to replace all the batteries at once?
Yes. Always replace the whole pack together; mixing old and new cells shortens the life of the new ones.
Eaton, Powerware, and PW5119 are trademarks of Eaton Corporation. UPSPLUSBATTERY.ca is not affiliated with, endorsed by, or authorized by the manufacturer; aftermarket batteries are compatible replacements.
Replacement battery cartridges for Eaton Powerware PW5119 Series UPS — the legacy line-interactive rack-mount UPS deployed across server cabinets and small data center racks throughout the early-2000s. Models supported include PW5119-1000VA, PW5119-1000i, PW5119-1Ki-RM, PW5119-1500i, PW5119-1.5ki-RM, PW5119-2000i, PW5119-2400i, PW5119-2.4Kii-RM, PW5119-2Ki-RM, PW5119-3000i, PW5119-3Ki-RM and rack-mount tower variants.
PW5119 cartridges typically use 12V 7Ah SLA cells in 6-cell, 8-cell, or 16-cell strings depending on capacity and voltage (120V vs 230V vs 208V). Always confirm the cartridge part number on your existing battery before ordering. PW5119 was succeeded by the Eaton 9130 platform after the 2007 Powerware-Eaton acquisition — if you're modernizing, consider migration to current Eaton 9PX or 9SX platforms.
Recommended swap window: 3-5 years per IEEE 1188; PW5119 systems still in service are often 15-20 years old, and battery replacement may be just one of several end-of-life decisions to make. For Eaton Powerware migration planning or PW5119 commissioning across Canada contact Eaton Service Canada.
Our Canadian team has specified APC, Eaton, Tripp Lite, Vertiv, Mitsubishi, Toshiba, CyberPower, XPC, and Delta UPS for healthcare, data centres, and government. Enquiries answered in business hours.