Eaton 5P Replacement Batteries

Eaton 5P Replacement Batteries

Replacement batteries for the Eaton 5P line-interactive UPS, 5P550 through 5P1550 rack and tower models.

Eaton 5P Replacement Batteries catalogue

Showing 1-24 of 72
Eaton 5P1000 Battery In stock
Eaton · 5P1000

Eaton 5P1000 Battery

Fits: 5P1000

Voltage
24 V
Capacity
9.0 Ah
Batteries
2
$76.99
Eaton 5P1550G Battery In stock
Eaton · 5P1550G

Eaton 5P1550G Battery

Fits: 5P1550G

Voltage
36 V
Capacity
9.0 Ah
Batteries
3
$114.99

Comparison

Replacing the whole UPS? Refurbished UPS: load-tested, new batteries, 1-year warranty →

Replacement battery cartridges for Eaton 5P series, Eaton's compact line-interactive UPS for IT closets, small server rooms, and edge deployments. Models supported include 5P 550, 5P 750, 5P 850, 5P 1150, 5P 1500, 5P 1550, 5P 2200, 5P 3000, plus rack-mount variants 5P 1500R, 5P 1550R, 5P 2200R, 5P 3000RT and tower-rack convertibles.

5P cartridges typically use the 5P850BAT, 5P1500BAT, 5P1550GR, 5P2200BAT, or 5P3000BAT replacement kit codes, always check the cartridge label printed on your existing battery before ordering. Hot-swap design lets you replace cartridges without dropping the load.

Recommended swap interval: 3-5 years per IEEE 1188. For commissioning or rack-mount install assistance contact Eaton Service Canada for Canada-wide service. Need to right-size before swap? Use the runtime calculator.

About Eaton 5P Replacement Batteries

Read more: Eaton 5P Replacement Batteries

Eaton 5P replacement batteries

The Eaton 5P is an entry-level line-interactive UPS for desktops, networking and small server loads, in rack and tower form from 550 VA (5P550R) to 3000 VA (5P3000). (It sits below the 5PX and 9PX in Eaton's range.) Its sealed lead-acid (VRLA) battery wears out after about 3 to 5 years; a new battery restores full runtime. Use this page to find the right battery for your exact 5P model.

For the wider range see Eaton replacement batteries.

Battery type

Most 5P models use 12 V VRLA batteries. Capacity and count vary by model, so match by your exact model number (e.g. 5P1500RC, 5P850G) rather than by VA alone.

How to identify the right battery

Find the model number on the rear label or LCD. Select the matching battery below, or send us your model number and we'll confirm the correct pack.

Eaton OEM vs compatible aftermarket

Both restore full runtime. Eaton OEM: kit supplied by Eaton, with the manufacturer's warranty. Compatible aftermarket: the same form factor and connector, with a 1-year UPSPLUSBATTERY warranty.

How long does it last?

3 to 5 years at 20 to 25 °C; heat roughly halves life for every ~8 °C above 25 °C. See when to replace a UPS battery.

How to replace

eaton.com lists the 5P batteries as user replaceable. On rack models the battery tray is front-accessible; on tower models the battery sits behind a panel:

  1. Confirm the correct battery for your model.
  2. Open the battery compartment or release the tray (power down first if your manual requires it).
  3. Disconnect the old battery and remove it.
  4. Fit the new battery (or set), reconnect observing polarity, and close up.
  5. Recharge and run a self-test.

See how to install a UPS battery.

FAQ

What battery does the 5P use?

12 V VRLA; the count and capacity vary by model. Match by exact model number.

Is the 5P battery the same as the 5PX?

No: 5P and 5PX are different ranges (the 5P has no EBM option; the 5PX takes EBMs); confirm against your exact model.

How often should I replace it?

Every 3 to 5 years; sooner in warm spaces.

Model names and trademarks belong to their respective owners. UPSPLUSBATTERY.ca is not affiliated with, endorsed by, or authorized by Eaton; aftermarket batteries are compatible replacements.

1-year warranty on our replacement batteries
Canadian specialists: 438-881-3363 · Contact us