Vertiv Liebert GXT5 Battery Replacements

Vertiv Liebert GXT5 Battery Replacements

Compatible replacement batteries and battery cartridge kits for Vertiv Liebert GXT5 online UPS systems.

Vertiv Liebert GXT5 Battery Replacements catalogue

Showing 1-19 of 19

Comparison

Replacing the whole UPS? Refurbished UPS: load-tested, new batteries, 1-year warranty →

Replacement batteries for the Vertiv Liebert GXT5 online double-conversion UPS line, 1500VA through 10000VA models commonly deployed in data centres, network closets, and edge IT sites. The GXT5 series uses internal hot-swap battery cartridges plus support for external GXT5-EBC72VRT2U and other extended-runtime cabinets.

Vertiv Liebert GXT5 Battery Specifications

  • Battery type: Sealed Lead Acid (SLA / VRLA) on standard models. Lithium-ion variants (GXT5-LI) for 8 to 10 yr service life.
  • External battery cabinet: GXT5-EBC72VRT2U for extended runtime (daisy-chainable per model spec)
  • Service life (VRLA): 3 to 5 years; environment-dependent. Every 8°C above 25°C halves SLA life (Arrhenius rule).
  • Service life (Li-ion): 8 to 10 years on GXT5-LI variants
  • Hot-swappable on all GXT5 models

Compatible Vertiv Liebert GXT5 Models

  • GXT5 1500VA: GXT5-1500IRT2UXLE, GXT5-1500LVRT2UXL
  • GXT5 2000VA: GXT5-2000IRT2UXLE
  • GXT5 3000VA: GXT5-3000IRT2UXL, GXT5-3000IRT2UXLE
  • GXT5 6000 to 10000VA: GXT5-6000HVRT9UXL, GXT5-10KIRT5UXL
  • GXT5-LI lithium-ion variants: GXT5LI-1000LVRT2UXL, GXT5LI-2000LVRT2UXL, GXT5LI-3000LVRT2UXL

Why Buy GXT5 Batteries From UPSPLUSBATTERY

  • Ships from Canada.
  • Our own compatible batteries, tested in house before they ship
  • 1-year warranty on every battery
  • Free Call2Recycle Canada disposal for old cells
  • Multi-unit fleet pricing, ideal for IT teams running GXT5 across distributed branches
  • Lithium-ion GXT5-LI options for sites prioritising long-term TCO and reduced battery-replacement labour

Calibration After Replacement

Calibrate via the GXT5 front-panel battery test or Vertiv RDU101 IS-UNITY remote management card so the UPS accurately reports runtime on the new pack. See our UPS battery calibration guide.

For Vertiv vs APC remote-monitoring comparison see our Vertiv vs APC remote monitoring guide. For Vertiv vs Eaton edge-IT selection see our Vertiv vs Eaton edge IT guide. Contact us with your exact GXT5 model number to verify compatibility before ordering. Multi-unit fleet contracts via our service partner.

About Vertiv Liebert GXT5 Battery Replacements

Read more: Vertiv Liebert GXT5 Battery Replacements

Which replacement battery does my Vertiv Liebert GXT5 use?

Vertiv's GXT5 brochures list one replacement battery kit per lead-acid model, named for its battery string voltage: from GXT5-36VBATKIT for the 500 to 1000 VA 120 V models up to GXT5-288VBATKIT for the 8 and 10 kVA MV models. The kit for each model is below.

Source: Vertiv Liebert GXT5 brochures SL-70414 (500 to 3000 VA, 120 V) and SL-70505 (3 to 10 kVA). For the 5 to 10 kVA models, Vertiv's note ties these kits to the batteries in the external battery cabinets; check the label on your batteries before ordering.

The Vertiv Liebert GXT5 is a double-conversion (online) rack/tower UPS used to protect servers, network gear, and other critical loads. Like every UPS in this class, it stores its backup energy in sealed lead-acid (VRLA) batteries that wear out and need periodic replacement. This collection brings together the compatible replacement batteries and cartridge kits for the GXT5 line so you can match the correct part to your specific unit.

What type of battery does the GXT5 use?

GXT5 models other than the lithium-ion GXT5LI use sealed, valve-regulated lead-acid (VRLA / SLA) cells. Individual cells are 12V, and the UPS connects several of them in series to reach the system DC voltage your model needs, which is why GXT5 cartridge kits are sold for specific system voltages (Vertiv lists GXT5-36VBATKIT, GXT5-48VBATKIT, GXT5-72VBATKIT, GXT5-144VBATKIT, GXT5-192VBATKIT and GXT5-288VBATKIT, plus GXT5-9A48BATKIT / GXT5-9A72BATKIT) rather than a single universal pack. Because capacity (Ah) and the number of cells differ from model to model, there is no single voltage or amp-hour figure that fits the entire family. The exact specification depends on your UPS or cartridge model. Each product page in this collection lists the voltage and amp-hour rating for that specific item.

How do I find the right GXT5 battery kit?

The reliable way to order is to match by exact model number, not by appearance. Check the nameplate label on your UPS, or the part number printed on your existing battery cartridge, and match it to the "compatible models" list shown on each product in this collection. Cartridge/kit part numbers (such as GXT5-72VBATKIT or GXT5-144VBATKIT) and the UPS model numbers they serve are both listed so you can confirm fitment before you buy. When in doubt, confirm by the exact model and review the specifications shown in the product grid.

Should I buy the Vertiv kit or a compatible battery?

Both restore runtime when matched to your model. You have two options when replacing GXT5 batteries: a kit sold under the manufacturer's brand, or a compatible cartridge matched on voltage, capacity, terminals and connectors. Manufacturer kits carry the manufacturer's branding and warranty. The right choice depends on your budget, warranty requirements, and internal policies.

How long does a GXT5 battery last?

VRLA UPS batteries typically last about 3 to 5 years under normal conditions. Heat is the single biggest factor that shortens that life: as a rule of thumb, every roughly 8°C (about 15°F) of sustained temperature above 25°C (77°F) can cut usable battery life roughly in half. Keeping the UPS in a cool, ventilated location and replacing batteries on schedule helps avoid an unexpected loss of protection.

Can I replace a GXT5 battery myself?

Yes. Vertiv describes the battery of the 500 to 3000 VA, 120 V GXT5 models as hot-swappable and user-replaceable, and the batteries in the 5 to 10 kVA external battery cabinets as user-replaceable. General steps for replacing a UPS battery cartridge:

  1. Order the correct cartridge for your exact model.
  2. Note the orientation and connections of the existing cartridge before removing anything.
  3. Release the front bezel / battery cover and slide the old cartridge out.
  4. Insert the new cartridge fully until the connector seats.
  5. Recharge fully (typically several hours) before relying on backup runtime, and dispose of or recycle the old batteries responsibly.

Hot-swap note: Hot-swapping (replacing batteries while the UPS keeps running) is supported only on units designed for it: rack/tower online UPS such as the GXT5 and hot-swap-capable Smart-UPS style models. Desktop and Back-UPS style units are not hot-swappable: power them down before changing the battery. If you are unsure whether your unit supports hot-swap, power it down to be safe.

Frequently asked questions

How do I know which battery my GXT5 needs? Match the model number on your UPS nameplate or existing cartridge to the compatible-models list on each product page. The product grid also shows the voltage and amp-hours for each item.

Are these batteries Vertiv parts? No. The batteries we sell are compatible replacements, matched on voltage, capacity, terminals and connectors; each product page lists its voltage and capacity.

How long do GXT5 batteries last? Typically 3 to 5 years, less in hot environments.

Can I replace the battery without shutting down the UPS? Yes on the 500 to 3000 VA, 120 V GXT5 models, which Vertiv describes as hot-swappable; for larger models, follow Vertiv's manual. Always follow the steps above and verify your specific configuration.

Where does the battery ship from? Orders ship from Canada.