APC Smart-UPS 3000 Battery Replacements
Replacement batteries for the APC Smart-UPS 3000 family, a 48 V VRLA system.
APC Smart-UPS 3000 Battery Replacements catalogue
APC Smart-UPS 3000VA SMT3000R2X180 Replacement Battery
- Voltage
- 48 V
- Capacity
- 10.0 Ah
- Batteries
- 8
APC Smart-UPS 3000VA SU3000RM5U Replacement Battery
- Voltage
- 48 V
- Capacity
- 18.0 Ah
- Batteries
- 4
APC Smart-UPS 3000VA SUA3000-BR Replacement Battery
- Voltage
- 48 V
- Capacity
- 18.0 Ah
- Batteries
- 4
APC Smart-UPS 3000VA SUA3000R2IX322 Replacement Battery
- Voltage
- 48 V
- Capacity
- 10.0 Ah
- Batteries
- 8
APC Smart-UPS 3000VA SUA3000RMI2U Replacement Battery
- Voltage
- 48 V
- Capacity
- 10.0 Ah
- Batteries
- 8
APC Smart-UPS XL 3000VA SUM3000RMXL2U Replacement Battery
- Voltage
- 48 V
- Capacity
- 10.0 Ah
- Batteries
- 8
APC Smart-UPS XL 3000VA SUM3000RMXLi2U Replacement Battery
- Voltage
- 48 V
- Capacity
- 10.0 Ah
- Batteries
- 8
APC SMT3000R2X145 Replacement Battery Set
- Voltage
- 48 V
- Capacity
- 10.0 Ah
- Batteries
- 8
APC SMT3000R2X180 Replacement Battery Set
- Voltage
- 48 V
- Capacity
- 10.0 Ah
- Batteries
- 8
APC SMT3000RM2UC Replacement Battery Kit
- Voltage
- 48 V
- Capacity
- 10.0 Ah
- Batteries
- 8
APC SMT3000RM2UNC Replacement Battery Set
- Voltage
- 48 V
- Capacity
- 10.0 Ah
- Batteries
- 8
APC SMT3000RMI2U Replacement Battery Set
- Voltage
- 48 V
- Capacity
- 10.0 Ah
- Batteries
- 8
APC SRT3000RMXLA Replacement Battery Set
- Voltage
- 96 V
- Capacity
- 5.0 Ah
- Batteries
- 8
APC SU3000I Battery Replacement Kit for Smart-UPS 3000VA
- Voltage
- 48 V
- Capacity
- 18.0 Ah
- Batteries
- 4
APC SU3000INET Replacement Battery Kit
- Voltage
- 48 V
- Capacity
- 18.0 Ah
- Batteries
- 4
APC SU3000INET Replacement Battery Set
- Voltage
- 48 V
- Capacity
- 18.0 Ah
- Batteries
- 4
APC SU3000R3BX120 Replacement Battery Set
- Voltage
- 48 V
- Capacity
- 14.4 Ah
- Batteries
- 8
APC SU3000R3BX135 Replacement Battery Kit
- Voltage
- 24 V
- Capacity
- 9.0 Ah
- Batteries
- 2
Replacing the whole UPS? Refurbished UPS: load-tested, new batteries, 1-year warranty →
Replacement batteries for the APC Smart-UPS 3000VA family, the workhorse of small-server-room and network-closet deployments. The SMT3000 and SMT3000C towers use the APC RBC55 cartridge; the 2U rack SMT3000RM2U, SMT3000RMT2U and SMT3000RMUS use the RBC43.
What Battery Does My APC Smart-UPS 3000 Take?
The SMT3000 towers use the RBC55 cartridge, a 48V pack of 12V 17Ah blocks, sealed lead-acid (SLA / VRLA), hot-swappable. Other 3000VA lines use different cartridges: APCRBC143 (Smart-UPS X SMX3000LVNC), APCRBC117 (SMX3000RMLV2U), APCRBC105 (Smart-UPS XL SUA3000RMXL3U), APCRBC140 (Smart-UPS RT SURT3000RMXLT, SURTA3000XL), APCRBC152 (Smart-UPS On-Line SRT3000XLA) and SYBT2-PLP (Symmetra LX 3000); always confirm the cartridge code on your existing battery label before ordering.
Common Smart-UPS 3000 Models
- SMT3000, SMT3000RM2U, SMT3000RMT2U, SMT3000RMUS, SMT3000C, SMT3000RM2UC
- SUA3000, SUA3000RM2U, SUA3000RMI, SUA3000RMXL3U
- Smart-UPS X 3000: SMX3000LVNC, SMX3000RMLV, SMX3000HV
Why Buy From UPSPLUSBATTERY
- Ships from Canada.
- Our own compatible batteries, tested in house before they ship
- 1-year warranty.
- Free Call2Recycle Canada disposal for old cells
- Multi-unit pricing for IT teams replacing multiple Smart-UPS 3000 batteries
After installation, calibrate the UPS via PowerChute or front-panel cycle, see our UPS battery calibration guide. For multi-unit fleet on-site replacement, our service partner covers Canada-wide. If you are not certain which cartridge your unit takes, start from the APC Smart-UPS replacement pack finder, which matches by model number rather than by VA rating.
About APC Smart-UPS 3000 Battery Replacements
Read more: APC Smart-UPS 3000 Battery Replacements
APC Smart-UPS 3000 replacement batteries
The APC Smart-UPS 3000 (3000 VA line-interactive) protects servers and other critical loads. Its batteries are a 48 V sealed lead-acid (VRLA) system that wears out after about 3 to 5 years and then needs replacement to restore full runtime. The exact replacement depends on your specific Smart-UPS 3000 model and generation, confirm yours below before ordering.
For the full range see APC replacement batteries and APC Smart-UPS batteries.
Which battery does my Smart-UPS 3000 take?
| Model generation | Replacement | Pack voltage |
|---|---|---|
| SMT3000, SMT3000RMI2U and rack/tower SMT variants | APCRBC55 (SMT3000); RBC43 (SMT3000RMI2U) | 48 V |
| Legacy SU3000, SU3000RM, SUA3000 sets | 48 V replacement battery set | 48 V |
Amp-hour rating varies by generation, so match by your exact model number rather than VA rating alone. Not sure which you have? The model number is on the rear or side label, send it to us and we'll confirm the correct pack.
How to identify the right battery
Read the model number on the unit's rear or side label (for example SMT3000RMI2U or SU3000RM3U). Newer SMT tower models take the APCRBC55 cartridge and the rack SMT3000RMI2U / SMT3000RM2U take RBC43; the legacy SU / SUA-series take a 48 V battery set. APC reuses designs across many SKUs, so your exact model number is the reliable key.
APC vs compatible aftermarket
Both restore full runtime. APC OEM: cartridge supplied by APC, with the manufacturer's warranty. Compatible aftermarket: the same 48 V form factor and connector, with a 1-year UPSPLUSBATTERY warranty.
How long does it last?
APC gives 3 to 5 years in a normal 20 to 25 °C environment. Heat is the main life-shortener: service life roughly halves for every ~8 °C of sustained operation above 25 °C. See when to replace a UPS battery.
How to replace
Smart-UPS 3000 batteries are user-replaceable and hot-swappable on current models (check the user manual): the UPS keeps protecting the load during the swap.
- Confirm the correct cartridge or set for your exact model.
- Open the battery compartment (front bezel on tower models; tray latch on rack models).
- Disconnect the battery connector.
- Slide the old pack out and the new one in.
- Reconnect until it clicks.
- Close up, run a self-test, and allow 8 to 24 hours for a full charge before relying on full runtime.
See how to install a UPS battery.
FAQ
What battery does the SMT3000 use?
The tower SMT3000 uses the APCRBC55 cartridge, a 48 V VRLA pack; the rack SMT3000RMI2U and SMT3000RM2U use RBC43 (48 V). Confirm against your model label.
What about an older SU3000?
Legacy SU3000 / SUA3000 models take a 48 V replacement battery set. Send us your model number and we'll match it.
OEM or aftermarket?
In-warranty unit: APC. Out of warranty: a compatible 48 V pack matched on voltage, capacity and connectors is the usual choice, with a 1-year warranty.
How often should I replace it?
Every 3 to 5 years; sooner in warm or poorly-ventilated spaces.
APC®, Smart-UPS® and APCRBC™ are registered trademarks of Schneider Electric / APC. UPSPLUSBATTERY.ca is not affiliated with, endorsed by, or authorized by APC by Schneider Electric; aftermarket batteries are compatible replacements.























