Battery for Tripp Lite SMX3000XLRT2U UPS
- Voltage
- 48 V
- Capacity
- 7.2 Ah
- Batteries
- 4
Compatible replacement batteries for the Tripp Lite SMX (SmartPro X) UPS line, matched to your exact model and shipped from Canada.
Replacing the whole UPS? Refurbished UPS: load-tested, new batteries, 1-year warranty →
Replacement battery cartridges for Tripp Lite SMX Series UPS, SmartPro line-interactive rack-mount UPS with LCD, network management card support, and pure sinewave output. Models supported include SMX1500LCDT, SMX1500RT2U, SMX2200XLRT2U, SMX2200LCDXLRT2U, SMX3000LCDRT2U, SMX3000XLRT2U, SMX5000XLRT3U plus 230V international variants (SMX1500LCDXL, SMX2200XL230RT2U).
SMX cartridges typically use Tripp Lite RBC92 (4-cell 12V 9Ah) or RBC93 (8-cell 12V 9Ah) replacement codes for SMX 1500-2200 systems, and larger string banks for SMX 3000-5000 rack-mount systems. Always confirm the cartridge code on your existing battery before ordering. Hot-swap design lets you replace cartridges without dropping the load on most SMX models.
Recommended swap interval: 3-5 years per IEEE 1188. SMX systems in production data center environments benefit from runtime calibration after every cartridge swap. For commissioning, rack install, or load-bank verification on Tripp Lite by Eaton SMX systems contact our service partner for Canada-wide service.
The Tripp Lite SMX line, also branded SmartPro X, is a family of line-interactive UPS systems ranging from compact 1U rack units to larger tower and rack/tower convertible models. Every model in this series relies on a string of internal valve-regulated sealed lead-acid (VRLA / SLA) batteries to carry your equipment through a power outage. Over time those cells lose capacity, and a new battery is the most effective way to restore runtime to a working UPS.
SMX batteries are built from individual 12-volt sealed lead-acid blocks. Smaller units use a single 12V battery, while larger units wire several blocks in series and/or parallel to reach a higher system voltage and greater capacity. That is why the correct voltage and amp-hour rating differs from one SMX model to the next. Because the configuration changes across the series, we do not quote one universal spec for the whole line. Instead, each product in this collection lists the exact voltage and amp-hour rating for that specific model in the product grid above.
The safest way to order is to match by the exact UPS model number. Find the model label on the rear or underside of your unit (for example SMX1000RT2U, SMX1500LCD, SMX3000XLRT2U or SMX5000XLRT3U) and select the product that names that model. Do not order by capacity alone or by physical size guesses. Confirming the model first prevents mismatched voltage, wrong terminal type, or a battery that does not fit the tray. The product grid above shows the matching specifications for each model.
You have two paths when a UPS battery reaches end of life. An OEM cartridge is supplied by the manufacturer and carries the original brand. A compatible battery is matched on voltage, capacity, terminals and connectors. The batteries in this collection are compatible replacements for the listed SMX models.
A UPS battery typically lasts 3 to 5 years under normal conditions. Heat is the biggest factor in how fast a battery ages: as a rule of thumb, battery life is roughly halved for every 8°C of sustained operating temperature above 25°C. Keeping the UPS in a cool, ventilated location and replacing the battery on schedule keeps your protection reliable.
Hot-swap note: Hot-swapping (replacing the battery while the UPS keeps running) is only appropriate for rack-mount, Smart-UPS style and online/double-conversion units that are designed with user-serviceable, hot-swappable battery modules. It is not appropriate for desktop or Back-UPS style units; those should be powered down and disconnected before changing the battery. When in doubt, power the unit down and follow the manual.
How do I know which battery fits my SMX UPS?
Match by your exact UPS model number. Locate the model label on your unit and choose the product that lists that model. The product grid shows the matching specs.
Why do voltage and amp-hours differ between products?
SMX models use different battery configurations depending on the size of the UPS, so the correct voltage and capacity vary by model. Each product page lists the right values for that unit.
Are these Tripp Lite batteries?
No. These are compatible replacements matched on voltage, capacity, terminals and connectors, for the listed models.
How long will the new battery last?
Typically 3 to 5 years, shorter in hot environments. Expect roughly half the life for every 8°C of sustained temperature above 25°C.
Can I replace the battery while the UPS is running?
Only on rack-mount, Smart-UPS style and online units designed for hot-swap. Power down desktop and Back-UPS style units first.
Model names and trademarks belong to their respective owners. UPSPLUSBATTERY.ca is not affiliated with, endorsed by, or authorized by the manufacturer; aftermarket batteries are compatible replacements.