Liebert GXT5LI-6000MVRT3UXLN 6000VA/6000W Rack/Tower UPS
| UPC | 767041035117 |
| 3U Rack/Tower - 8.50 Minute Stand-by - 120 V AC, 230 V AC Input - 120 V AC, 240 V AC Output - Single Phase - Pure Sine Wave - Serial Port - USB - LCD Display | |
| General Information | |
|---|---|
| Manufacturer: | Vertiv |
| Manufacturer Part Number: | GXT5LI-6000MVRT3UXLN |
| Manufacturer Website Address: | http://www.vertiv.com/ |
| Brand Name: | Liebert |
| Product Model: | GXT5LI-6000MVRT3UXLN |
| Product Name: | GXT5LI-6000MVRT3UXLN 6000VA/6000W Rack/Tower UPS |
| Marketing Information: | The Vertiv Liebert GXT5 Lithium-Ion UPS (5-10kVA) protects critical IT applications from outages and power disturbances. This online high-capacity UPS offers the highest level of power conditioning and battery backup in server rooms, network closets, and other edge or distributed IT locations. Lithium-Ion batteries require fewer battery replacements and last up to 3x as long as VRLA batteries reducing maintenance, labor, and replacement costs (resulting in the lowest TCO). They provide industry-leading runtime (up to 14 minutes at full load) to protect critical equipment during an unexpected power loss. They give better performance at higher temperatures, support up to 10 times more discharge cycles, and deliver faster recharge times compared to VRLA batteries. The UPS has Integrated Maintenance Bypass Cabinet (MBC) which provides continuous power to connected equipment even during UPS maintenance or replacement, if needed. It also has RDU101 SNMP/Webcard for remote management. |
| Product Type: | Double Conversion Online UPS | Technical Information |
| Plug/Connector Type: | Hardwired |
| Receptacle Type: | Hardwired |
| Protection Type: |
|
| Transfer Time: | 0 ns |
| Phase: | Single Phase |
| Application/Usage: |
|
Power Description |
| Load Capacity (VA): | 6 kVA |
| Load Capacity (Watt): | 6 kW |
| Input Voltage: |
|
| Input Voltage Range: | 120 V AC - 240 V AC |
| Output Voltage: |
|
| Waveform Type: | Pure Sine Wave |
| Circuit Breaker: | Yes | Display & Graphics |
| Display: | LCD | Controls/Indicators |
| Status Indicators: | LED & LCD |
Interfaces/Ports |
| Serial Port: | Yes |
| VGA: | No |
| Modem (RJ-11): | No |
| Network (RJ-45): | Yes |
| USB: | Yes | Battery Information |
| Battery Chemistry: | Lithium Ion (Li-Ion) |
| Backup/Run Time (Full Load): | 8.50 Minute |
| Backup/Run Time (Half Load): | 19 Minute |
| Hot Swappable: | Yes | Physical Characteristics |
| Height: | 5.20" (132.08 mm) |
| Width: | 16.90" (429.26 mm) |
| Depth: | 35" (889 mm) |
| Rack Height: | 3U |
| Form Factor: | Rack/Tower |
| Weight (Approximate): | 45.4 kg | Miscellaneous |
| Package Contents: |
|
| Energy Star: | Yes |
| Country of Origin: | China |
| TAA Compliant: | No |
| Environmentally Friendly: | Yes |
| Environmental Compliance: |
|
Warranty |
| Limited Warranty: | 5 Year |
Technical specifications
Setup checklist: after you receive your UPS →
How long it'll keep your equipment up.
Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.
Need more runtime? This UPS accepts external battery packs (XBPs). Contact us about XBP options →
Compare with alternatives
The GXT5LI-6000MVRT3UXLN side by side with UPS from other makers.
-
Compared with GXT5LI-6000MVRT3UXLN Spec GXT5LI-6000MVRT3UXLN 360PQ Capacity 6000 VA / 6000 W 6000 VA / 6000 W Topology Online Double-Conversion Online Double-Conversion Form Tower/Rack Convertible, 3U Tower/Rack Convertible Input plug Hardwired Hardwired Outlets 1 × Hardwire terminal block 1 × Hardwire terminal block Runtime, half load 21 min Not stated Differences
- Input 208 V only; this model also accepts 240 V
- Network card not included
Price confirmed by quote Request a quote -
Compared with GXT5LI-6000MVRT3UXLN Spec GXT5LI-6000MVRT3UXLN Delta Capacity 6000 VA / 6000 W 6000 VA / 6000 W Topology Online Double-Conversion Online Double-Conversion Form Tower/Rack Convertible, 3U Tower/Rack Convertible, 4U Input plug Hardwired Hardwired Outlets 1 × Hardwire terminal block 2 × NEMA L6-20R, 1 × NEMA L6-30R, 1 × NEMA L6-30R, 1 × Hardwire terminal block (4 on battery) Runtime, half load 21 min Not stated Differences
- Input 208 V only; this model also accepts 240 V
- Takes 4U of rack space instead of 3U
- Network card not included
Price confirmed by quote Request a quote -
Xtreme Power Conversion
Xtreme Power TX91-6K 6000 VA / 6000 W Online Isolated UPS, 208/230 V
Compared with GXT5LI-6000MVRT3UXLN Spec GXT5LI-6000MVRT3UXLN Xtreme Power Capacity 6000 VA / 6000 W 6000 VA / 6000 W Topology Online Double-Conversion Online Double-Conversion Form Tower/Rack Convertible, 3U Tower Input plug Hardwired Hardwired Outlets 1 × Hardwire terminal block 1 × Hardwire terminal block Runtime, half load 21 min 20 min Differences
- Input 208 V only; this model also accepts 240 V
- Tower only, no rack mounting
- Network card not included
Price confirmed by quote Request a quote
Check outlets and the runtime your load needs before ordering. Questions? Call 438-881-3363 or ask for a quote.
Works with this UPS
Only accessories the manufacturer lists for this model.
Questions before you buy
How do I know this UPS will run my equipment?
Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating (not VA) is the number that matters. Aim for the UPS to run at 60 to 70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list; we'll respond within one business day with sizing guidance.
What's covered by the warranty, and how long does it last?
New units carry the warranty coverage stated by the manufacturer; see the product listing or manufacturer documentation for the applicable terms. Refurbished units are covered by the 1-year UPSPLUSBATTERY warranty handled in Canada.
Can I extend runtime beyond what's shown above?
Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model; contact us if you don't see the right XBP in our catalogue.