Skip to product information
1 of 1

Tripp Lite

Tripp Lite by Eaton SmartOnline S3M60KX 60kVA Tower UPS - S3M60KX - Delta Conversion Online UPS, Tower, Pure Sine Wave, 230 V AC,380 V AC,400 V AC,415 V AC, SmartOnline S3MX, 60 kVA

Tripp Lite by Eaton SmartOnline S3M60KX 60kVA Tower UPS - S3M60KX - Delta Conversion Online UPS, Tower, Pure Sine Wave, 230 V AC,380 V AC,400 V AC,415 V AC, SmartOnline S3MX, 60 kVA

Quote on request
Request a quote →

Items above $10000 are handled by quote so we can confirm availability, freight, and final pricing.

Written reply within 1 business day — no obligation.

  • Ships from our Canadian warehouse — CAD pricing, no customs
  • New in box — manufacturer warranty applies
  • Purchase orders / Net-30 welcome (B2B & public sector)

Questions? 438-881-3363 · Mon–Fri

View full details
Product details

About this UPS

Product Features:
  • Brand: Tripp Lite by Eaton
  • Product Type: Delta Conversion Online UPS
  • Manufacturer Part Number: S3M60KX
  • Form Factor: Tower
  • Waveform Type: Pure Sine Wave
  • Product Family: SmartOnline S3MX
  • Load Capacity: 60 kVA

  • Marketing Information:

    Battery Backup and VFI Operation Protect Critical Loads

    The SmartOnline ® S3M60KX IGBT UPS supports the continuous availability of your most important loads through all power conditions, providing a compact backup power platform that's easy to manage and inexpensive to operate. Sophisticated voltage and frequency independent (VFI) operation and advanced IGBT rectifier technology with DSP control deliver reliable output power quality. Providing up to 60kVA of clean, continuous power, this 3-phase UPS system is perfect for critical applications in IT, communications, corporate, commercial, retail, financial, security, transportation, emergency and light industrial environments.

    Best-in-Class Footprint for Easy Integration into Your Network Application

    This on-line double-conversion UPS system has a very small footprint of just 0.28 square meters. It requires less valuable space in your facility, and you can install the UPS system in spaces that would previously have required expensive retrofitting.

    Efficient Operation and Design Reduces Cost of Ownership

    This IGBT UPS benefits from highly efficient transformer-free double-conversion technology that delivers operating cost savings. It achieves 94% efficiency in double-conversion mode and up to 98% in ECO mode, reducing your power and cooling costs. A low THDi (<3%) improves generator compatibility. A low THDv (≤2%) and active power factor correction improve output performance. The hardware and firmware platform design reduces the number of unique boards, improving mean time to repair (MTTR) and resulting in reduced downtime. Built-in static and maintenance bypass transfer UPS load to utility power during faults, overloads and maintenance, which also avoids costly system downtime.

    External Batteries Supply Reliable Backup with Expandable Runtime Options

    The S3M60KX uses external scalable battery cabinets, such as BP480V40, BP480V65 and BP480V100 (sold separately), to provide up to three hours of backup support in case of a power failure. The UPS system automatically restarts after a lengthy power outage.

    Intuitive LCD Interface Delivers Important Performance Information at a Glance

    The interactive front-panel LCD interface displays critical operating conditions and diagnostic data, including operating mode, input/output voltage, load, battery voltage, backup runtime and fault conditions. Four LEDs provide information about line, bypass, battery and fault status.

    Network Management Card Offers Remote Monitoring and Control

    The optional Java-free WEBCARDLX network management card (sold separately) enables remote management through embedded HTML5 web, SSH/telnet and SNMP interfaces, as well as integration with a wide range of network management systems and DCIM platforms. A Remote Emergency Power Off (REPO) port allows shutdown from a safe distance during emergencies.

    Parallel Capability Provides Additional Capacity and Redundancy up to 3 Units

    Connect up to three S3M60KX units in parallel using separate/shared battery cabinets for increased capacity.

Product Specifications:
Product Features:
  • Manufacturer:Eaton Corporation
  • Manufacturer Part Number:S3M60KX
  • Manufacturer Website Address:https://tripplite.eaton.com/
  • Brand Name:Tripp Lite by Eaton
  • Product Line:SmartOnline
  • Product Series:S3MX
  • Product Model:S3M60KX
  • Product Name:SmartOnline S3M60KX 60kVA Tower UPS

  • Marketing Information:

    Battery Backup and VFI Operation Protect Critical Loads

    The SmartOnline ® S3M60KX IGBT UPS supports the continuous availability of your most important loads through all power conditions, providing a compact backup power platform that's easy to manage and inexpensive to operate. Sophisticated voltage and frequency independent (VFI) operation and advanced IGBT rectifier technology with DSP control deliver reliable output power quality. Providing up to 60kVA of clean, continuous power, this 3-phase UPS system is perfect for critical applications in IT, communications, corporate, commercial, retail, financial, security, transportation, emergency and light industrial environments.

    Best-in-Class Footprint for Easy Integration into Your Network Application

    This on-line double-conversion UPS system has a very small footprint of just 0.28 square meters. It requires less valuable space in your facility, and you can install the UPS system in spaces that would previously have required expensive retrofitting.

    Efficient Operation and Design Reduces Cost of Ownership

    This IGBT UPS benefits from highly efficient transformer-free double-conversion technology that delivers operating cost savings. It achieves 94% efficiency in double-conversion mode and up to 98% in ECO mode, reducing your power and cooling costs. A low THDi (<3%) improves generator compatibility. A low THDv (≤2%) and active power factor correction improve output performance. The hardware and firmware platform design reduces the number of unique boards, improving mean time to repair (MTTR) and resulting in reduced downtime. Built-in static and maintenance bypass transfer UPS load to utility power during faults, overloads and maintenance, which also avoids costly system downtime.

    External Batteries Supply Reliable Backup with Expandable Runtime Options

    The S3M60KX uses external scalable battery cabinets, such as BP480V40, BP480V65 and BP480V100 (sold separately), to provide up to three hours of backup support in case of a power failure. The UPS system automatically restarts after a lengthy power outage.

    Intuitive LCD Interface Delivers Important Performance Information at a Glance

    The interactive front-panel LCD interface displays critical operating conditions and diagnostic data, including operating mode, input/output voltage, load, battery voltage, backup runtime and fault conditions. Four LEDs provide information about line, bypass, battery and fault status.

    Network Management Card Offers Remote Monitoring and Control

    The optional Java-free WEBCARDLX network management card (sold separately) enables remote management through embedded HTML5 web, SSH/telnet and SNMP interfaces, as well as integration with a wide range of network management systems and DCIM platforms. A Remote Emergency Power Off (REPO) port allows shutdown from a safe distance during emergencies.

    Parallel Capability Provides Additional Capacity and Redundancy up to 3 Units

    Connect up to three S3M60KX units in parallel using separate/shared battery cabinets for increased capacity.


    PRODUCT SPECIFICATIONS
    Overload Protection Yes
    Phase Three Phase
    Application/Usage
    • Mission Critical Equipment
    • IT Infrastructure
    • Communication Application
    • Corporate
    • Commercial
    • Retail & Wholesale
    • Finance
    • Security
    • Transportation
    • Emergency
    • Industrial
    • Network
    • Telecommunication
    • Data Center
    • Automation System
    • Production Line Operation
    Load Capacity (VA) 60 kVA
    Output Voltage
    • 230 V AC
    • 380 V AC
    • 400 V AC
    • 415 V AC
    Output Frequency 60 Hz
    Waveform Type Pure Sine Wave
    Network Management
    • SSH
    • Telnet
    • SNMP Manageable
    Alarm
    • Bypass Mode
    • Battery Mode
    • Fault Mode
    • Overload
    Status Indicators interactive front-panel LCD interface:
    • Operating mode
    • Input / output voltage & frequency
    • Load
    • Battery voltage
    • Backup runtime
    • Fault conditions
    • alarm status
    • battery charge
    • Estimated runtime
    LEDs:
    • Line
    • Bypass
    • Battery
    • Fault
    Serial Port Yes
    EPO Port Yes
    DC System Voltage 240 V DC
    Typical Battery Recharge Time 9 Hour
    Maximum Operating Temperature 104 °F (40 °C)
    Storage Temperature 32 °F (0 °C) - 95 °F (35 °C)
    Maximum Operating Elevation 3280 ft (999744 mm)
    Form Factor Tower
    Height 39.76" (1010 mm)
    Width 14.17" (360 mm)
    Depth 31.10" (790 mm)
    Weight (Approximate) 237.99 lb (107950 g)
    Country of Origin China
    Limited Warranty 2 Year
    Specifications

    Technical specifications

    Power
    VA Rating
    60000VA
    Wattage
    54000W
    Topology
    Online Double-Conversion
    Waveform
    Pure Sine Wave
    Input
    Input Voltage
    240V
    Output
    Output Voltage
    230V
    Features
    Form Factor
    Tower
    Connectivity
    ["RS-232 Serial""SNMP (via Network Management Card)""HTTP/Web Management"]
    Condition
    New
    Operating Temperature
    0 to 40 °C (32 to 104 °F)
    Dimensions
    1010 × 360 × 790 mm (39.76 × 14.17 × 31.10 in)
    Weight
    107.95kg
    Manufacturer Warranty
    2 years
    Backup runtime

    How long it'll keep your equipment up.

    Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.

    Half load (27000 W) 7.0 min

    Approximate - based on a single manufacturer anchor point. Estimates are roughest near very light or very heavy loads.

    W
    Estimated runtime min

    Estimate based on manufacturer-specified runtime curve. Real-world runtime varies with battery age, ambient temperature, and load profile.

    Shipped across Canada
    Shipped from our Canadian warehouse. See shipping policy for rates and timing.
    Manufacturer-backed
    New UPS units carry the full manufacturer warranty registered to you on receipt.
    14 years in business
    UPSPLUSBATTERY has supplied Canadian UPS systems since 2012.
    Sizing & install help
    Email your load profile — we'll spec the right UPS within one business hour.
    Frequently asked

    Before you order

    How do I know this UPS will run my equipment?

    Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating — not VA — is the number that matters. Aim for the UPS to run at 60–70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list and we'll size the right UPS within one business hour.

    What's covered by the warranty, and how long does it last?

    New units carry the full manufacturer warranty registered to you on receipt. The manufacturer handles claims directly via their North American support channel. Refurbished units are covered by our own 1-year UPSPLUSBATTERY warranty handled in-house in Canada.

    Can I extend runtime beyond what's shown above?

    Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model — contact us if you don't see the right XBP in our catalogue.