About this UPS
- Brand: Tripp Lite by Eaton
- Product Type: Line-interactive UPS
- Manufacturer Part Number: SMART1200XLHGL
- Input Voltage: 120 V AC
- Form Factor: Tower,Wall Mountable
- Product Family: SmartPro
- Backup/Run Time (Full Load): 10 Minute
- Load Capacity: 1 kVA/750 W
- Compliant with UL 60601-1 standards for use in patient-care vicinities when plugged into a hospital-grade outlet
- Built-in isolation transformer with Faraday shield offers full isolation and reduces cumulative leakage current of connected equipment to less than 100 µA
- Hospital-grade NEMA 5-15P-HG plug with 6 ft. cord provides flexibility in placement
- Supports half load for 28 min. and full load for 10 min. with standard LiFePO4 internal battery
- Hospital-grade NEMA 5-15R-HG outlets provide 940 joules of surge protection
- EMI/RFI noise filtering ensures equipment runs smoothly without line noise interference
- Resistant to electrostatic discharge
- 10,000-cycle LiFePO4 battery
- Indicator lights monitor when the UPS is on and supplying utility power, when operating in voltage correction mode or in battery mode, relative load level and low-battery warning
- Audible alarms alert you to power failure, overload and low battery conditions
- Mute/quiet mode ensures "alarm fatigue" compliance
- Works with Tripp Lite PowerAlert software (available as a free download) to enable safe, unattended system shutdown and files saves during prolonged power failures
- Connects to your computer via DB9 or USB port
Marketing Information: Tripp Lite's SMART1200XLHGL medical-grade UPS system provides dependable lithium iron phosphate (LiFePO4) battery backup, so you can work through short power failures and perform an orderly system shutdown in a prolonged blackout. It's fully compliant with UL 60601-1 regulations when plugged into a hospital-grade outlet, making it ideal for use in patient-care vicinities. The 1kVA/750W capacity provides up to 28 minutes of runtime for a half load and 10 minutes for a full load.Built-in line-interactive voltage regulation corrects brownouts as low as 81V and overvoltages as high as 143V to normal 120V nominal output, without drawing battery power. A built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all modes. It also reduces the cumulative leakage current of connected equipment to less than 100 µA. Floating AC output prevents noise coupling from noisy hospital ground systems.This UPS system features four NEMA 5-15R-HG hospital-grade outlets and has a hospital-grade NEMA 5-15P-HG plug with a six-foot cord for flexibility in placement. All four outlets provide both backup protection and 940 joules of surge protection.The SMART1200XLHGL also features diagnostic LEDs, as well as a USB port and a DB9 serial port that work with Tripp Lite's free downloadable PowerAlert ® software for safe, unattended system shutdown and file saves in the event of a prolonged power failure.
Provides Ideal UPS Backup in Healthcare Facilities
Battery Backup and Full Surge Protection
LEDs and Audible Alarms Keep You Aware of Power Status
Saves Your Files, Even When You're Away
| PRODUCT SPECIFICATIONS | |
|---|---|
| Receptacle Type | NEMA 5-15R |
| Receptacle Detail | 4 x NEMA 5-15R |
| Transfer Time | 4 ms |
| Load Capacity (VA) | 1 kVA |
| Load Capacity (Watt) | 750 W |
| Input Voltage | 120 V AC |
| Output Voltage | 120 V AC |
| Backup/Run Time (Full Load) | 10 Minute |
| Typical Battery Recharge Time | 4.50 Hour |
| Height | 12.50" (317.50 mm) |
| Width | 7.50" (190.50 mm) |
| Depth | 9.50" (241.30 mm) |
| Form Factor |
|
| Weight (Approximate) | 33.60 lb (15240.70 g) |
| Package Contents |
|
| Country of Origin | United States |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Limited Warranty | 5 Year |
Technical specifications
Setup checklist: after you receive your UPS →
How long it'll keep your equipment up.
Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.
Compare with alternatives
The SMART1200XLHGL side by side with UPS from other makers.
-
Xtreme Power Conversion
Xtreme Power S71-1500 1500 VA / 900 W Line-Interactive UPS, 120 V
Compared with SMART1200XLHGL Spec SMART1200XLHGL Xtreme Power Capacity 1000 VA / 750 W 1500 VA / 900 W Topology Line-Interactive Line-Interactive Form Tower Tower Input plug NEMA 5-15P NEMA 5-15P Outlets 4 × NEMA 5-15R 6 × NEMA 5-15R Runtime, half load 28 min Not stated Differences
- Larger unit: 900 W instead of 750 W
$522.80 -
Xtreme Power Conversion
Xtreme Power P80-800 800 VA / 720 W Line-Interactive UPS, 120 V
Compared with SMART1200XLHGL Spec SMART1200XLHGL Xtreme Power Capacity 1000 VA / 750 W 800 VA / 720 W Topology Line-Interactive Line-Interactive Form Tower Tower/Rack Convertible, 2U Input plug NEMA 5-15P NEMA 5-15P Outlets 4 × NEMA 5-15R 8 × NEMA 5-15R Runtime, half load 28 min 11 min Differences
- Slightly lower rating: 720 W instead of 750 W
- Lower VA rating: 800 VA instead of 1000 VA
$1,068.18 -
Compared with SMART1200XLHGL Spec SMART1200XLHGL Delta Capacity 1000 VA / 750 W 1000 VA / 900 W Topology Line-Interactive Online Double-Conversion Form Tower Tower/Rack Convertible, 2U Input plug NEMA 5-15P NEMA 5-15P Outlets 4 × NEMA 5-15R 8 × NEMA 5-15R Runtime, half load 28 min 10 min Differences
- Online double-conversion, a step up from line-interactive
- Larger unit: 900 W instead of 750 W
$1,777.99
Check outlets and the runtime your load needs before ordering. Questions? Call 438-881-3363 or ask for a quote.
Questions before you buy
How do I know this UPS will run my equipment?
Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating (not VA) is the number that matters. Aim for the UPS to run at 60 to 70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list; we'll respond within one business day with sizing guidance.
What's covered by the warranty, and how long does it last?
New units carry the warranty coverage stated by the manufacturer; see the product listing or manufacturer documentation for the applicable terms. Refurbished units are covered by the 1-year UPSPLUSBATTERY warranty handled in Canada.
Can I extend runtime beyond what's shown above?
Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model; contact us if you don't see the right XBP in our catalogue.