Eaton 9PX11KTF11M 11000 VA / 10000 W Rack/Tower Online UPS 9U
- Power
- 11000 VA / 10000 W
- Form
- Tower/Rack Convertible
- Outlets
- 8× NEMA 5-20R, 3× NEMA L6-30R, 2× NEMA L14-30R, 1× Hardwire terminal block
We confirm price and freight before ordering.
Tripp Lite SU10000RT3U2TF 10,000VA / 10kVA / 9000 watt online, double-conversion UPS system offers complete power protection for critical network applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking applications. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included detachable PDU with manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.
| PRODUCT SPECIFICATIONS | |
|---|---|
| Plug/Connector Type | Hard Wire 3-wire |
| Receptacle Type |
|
| Receptacle Detail |
|
| Bypass Switch | Manual |
| Emergency Power OFF | Yes |
| Load Capacity (VA) | 10 kVA |
| Load Capacity (Watt) | 9 kW |
| Input Voltage |
|
| Output Voltage | 208 V AC |
| Network Management | SNMP Manageable |
| Serial Port | Yes |
| Backup/Run Time (Full Load) | 6 Minute |
| Backup/Run Time (Half Load) | 12 Minute |
| Typical Battery Recharge Time | 8 Hour |
| Hot Swappable | Yes |
| Height | 40" (1016 mm) |
| Width | 26" (660.40 mm) |
| Depth | 41" (1041.40 mm) |
| Rack Height | 10U |
| Form Factor | Rack/Tower |
| Weight (Approximate) | 435 lb (197312.68 g) |
| Package Contents |
|
| Additional Information |
|
| Certifications & Standards |
|
| Software Included | PowerAlert UPS monitoring software |
| Country of Origin | China |
| Limited Warranty | 2 Year |
Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.
Need more runtime? This UPS accepts external battery packs (XBPs). Contact us about XBP options →
The manufacturer no longer makes the SU10000RT3U2TF. These UPS are sold today; each card compares one with the discontinued model.
| Spec | SU10000RT3U2TF | Xtreme Power |
|---|---|---|
| Capacity | 10000 VA / 9000 W | 10000 VA / 10000 W |
| Topology | Online Double-Conversion | Online Double-Conversion |
| Form | Rackmount 5U+, 10U | Tower/Rack Convertible, 5U |
| Input plug | Hardwired | Hardwired |
| Outlets | 24 × NEMA 5-15/20R, 4 × NEMA L6-20R, 2 × NEMA L6-30R | 1 × Hardwire terminal block |
| Runtime, half load | 13 min | 15 min |
Differences
| Spec | SU10000RT3U2TF | Delta |
|---|---|---|
| Capacity | 10000 VA / 9000 W | 10000 VA / 10000 W |
| Topology | Online Double-Conversion | Online Double-Conversion |
| Form | Rackmount 5U+, 10U | Tower/Rack Convertible, 5U |
| Input plug | Hardwired | Hardwired |
| Outlets | 24 × NEMA 5-15/20R, 4 × NEMA L6-20R, 2 × NEMA L6-30R | 2 × NEMA L6-20R, 2 × NEMA L6-30R, 1 × NEMA L6-30R, 1 × Hardwire terminal block (5 on battery) |
| Runtime, half load | 13 min | Not stated |
Differences
Check outlets and the runtime your load needs before ordering. Questions? Call 438-881-3363 or ask for a quote.
The manufacturer no longer makes the SU10000RT3U2TF. These UPS are sold today; each card compares one with the discontinued model.
Questions? Call 438-881-3363 or ask for a quote.
Only accessories the manufacturer lists for this model.
A line-interactive UPS typically needs new batteries every 3 to 5 years. Matching replacement cartridges are listed by UPS model; confirm the exact model before ordering.
Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating (not VA) is the number that matters. Aim for the UPS to run at 60 to 70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list; we'll respond within one business day with sizing guidance.
New units carry the warranty coverage stated by the manufacturer; see the product listing or manufacturer documentation for the applicable terms. Refurbished units are covered by the 1-year UPSPLUSBATTERY warranty handled in Canada.
Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model; contact us if you don't see the right XBP in our catalogue.