Xtreme Power J60i-350 350 VA / 200 W Lithium-Ion UPS, 230 V
- Power
- 350 VA / 200 W
- Form
- DIN Rail / Panel Mount
- Outlets
- 2× IEC 60320 C13
Xtreme Power Conversion 208 V and 230 V UPS: P80g sinewave, T91i online tower, P91g and P91g Li online 2U, P91 5/6/10 kVA Unity PF, J90i lithium 1U, plus three-phase M90, X90, Li90, E91.
Not sure which one fits? Open the UPS Solutions Builder →
208/230V UPS systems for high-density rack environments and international deployments, L6-20P, L6-30P, and IEC C20 input.
208/230V UPS systems support twice the load on the same circuit current as 120V, essential for high-density rack environments where you need to run 5kVA+ loads on practical-sized circuits. Common in data centers, server rooms, and international (non-North American) deployments where 230V is standard.
The Xtreme Power 208/230V catalogue covers 800VA to 10kVA across the P80g, P91g, P91 (5-10kVA), TX91, TX91L, and TXVR series. Choose from line-interactive, online, isolated online, and voltage-regulated options.
At 208 V or 230 V, a given watt of load draws roughly half the line current of the same load at 120 V. Half the current means quarter the I²R loss in cabling, smaller breakers, smaller conductors, and standard locking L6-30 receptacles in nearly every rack PDU. For dense IT racks, three-phase facilities, and edge data centres, 208/230 V single-phase or 208/120 V three-phase is the efficient and conventional voltage. Step down to 120 V only when continuous load is below ~2.4 kW.
XPC's 208/230 V catalog: P80g 3 / 5 kVA line-interactive sinewave, T91i 2/3 kVA online, P91g and P91g Li 1–3 kVA online (Unity PF), P91 5 / 6 / 10 kVA Unity PF, J90i 1U lithium, plus the three-phase M90S split-phase, M90C three-phase, M90U / M90LU / M90U-80 / M90U-140, Li90 lithium three-phase, E91 three-phase, and X90 1S / 2S 480 V three-phase up to 140 kVA. UPSPLUSBATTERY.CA stocks the range with matching XPC battery packs. For lower-power 120 V SKUs see XPC 120 V UPS. For full XPC catalog see Xtreme Power Conversion.
| Series | Topology | Power range | Phase | Connection |
|---|---|---|---|---|
| P80g | Line-interactive sinewave | 3 / 5 kVA | Single-phase 208–230 V | L6-30P or hard-wired |
| T91i | Online tower | 2 / 3 kVA | Single-phase 208–230 V | IEC C20 inlet |
| P91g / P91g Li | Online, Unity PF | 1 to 3 kVA | Single-phase 200/208/220/230/240 V | IEC C20 inlet |
| J90i | Online, Lithium 1U | 1 / 1.5 / 2 / 3 kVA | Single-phase 230 V | IEC C14 inlet |
| P91 5K / 6K / 10K | Online, Unity PF | 5 / 6 / 10 kVA | Single-phase 208–240 V | L6-30P (5/6K) or terminal block (10K) |
| M90S | Modular Online split-phase | 6 / 12 / 18 / 24 / 30 / 36 / 42 / 48 kVA | 120/208 V or 120/240 V | Hard-wired |
| M90C | Modular Online three-phase | 5 / 8 / 10 / 15 / 16 / 24 kVA | 120/208 V three-phase | Hard-wired |
| M90U / M90LU | Modular Online, Unity PF three-phase | 15 to 60 kVA | 208/120 V three-phase | Hard-wired |
| M90U-80 / M90U-140 | Modular Online, Unity PF | 80 / 140 kVA | 208/120 V three-phase | Hard-wired |
| Li90 | Modular Online, LiFePO₄ | 10 / 20 / 30 kVA | 208/120 V three-phase | Hard-wired |
| E91 | Online three-phase, internal batteries | varies | Three-phase | Hard-wired |
| X90-1S / X90-2S | Modular Online, top-entry | 50 / 70 / 100 / 140 kVA | 480 V three-phase | Hard-wired |
Most rack-level UPS deployments under 10 kVA run single-phase 208/230 V on L6-30P or hard-wired. Three-phase is required when the upstream distribution is three-phase and you want to balance load across phases, typical at 10 kVA+ in branch data centres and dense compute aisles.
2U Unity PF online, selectable input/output 208/220/230/240 V. P91-5K and P91-6K ship with NEMA L6-30P 6-foot input cord, drop into a dedicated 30 A 208 V circuit. P91-10K is hard-wired. Optional XBDM-P91 maintenance bypass distribution modules (with L6-30P input or terminal block) for service without dropping load.
M90S is the split-phase 120/208 or 120/240 V family, common where existing distribution gives split-phase. M90C is three-phase 208/120 V, common in commercial three-phase services. M90U / M90U-80 / M90U-140 are Unity PF Modular Online, for 15 to 140 kVA three-phase IT and facility. X90 1S / 2S is 480 V three-phase top-entry for data-centre-scale 50–140 kVA. Li90 is the lithium variant of three-phase 208/120 V at 10–30 kVA.
P91 5–10 kVA: BPXR2U240A or BPXR3U240A external battery packs. P91g / T91i: P91-BP series. M90 / X90 / Li90: matching battery cabinets (M90-BC, X90-BC) with hot-swap modules. SLA cartridges in stock as compatible aftermarket, 1-year UPSPLUSBATTERY warranty. Lithium packs factory XPC only. Browse XPC battery packs.
P80g and P91 5/6 kVA on L6-30P plug, dedicated 30 A 208/230 V circuit by licensed electrician per CSA. P91-10K, M90, X90, Li90, E91 hard-wired only. M90 / X90 / Li90 commissioning by a qualified XPC technician, site survey recommended before order. Warranty (USA and Canada) by series: P80g, T91i, P91g 3-year; P91 5–10 kVA 3-year standard, 5-year optional; J90i 6-year; P91g Li 6-year; M90U 2-year; Li90 5x8 startup + 2-year on-site, 5-year parts-limited battery; X90 with 5x8 startup + on-site service plans. Coordinated through our Canadian team. Shipped from Canada: see shipping policy for rates and timing.
Half the line current at the same watt rating, smaller breakers, smaller conductors, less voltage drop, lower thermal load in the rack. Standard rack PDUs are L6-30 fed from 208 V. For dense racks above 2.4 kW continuous, 208 V is the practical default.
P91g and most M90 / X90 series accept both. 208 V is standard for North American three-phase derived single-phase. 230 V is European-style. Most Canadian commercial sites are 208 V. UPS internally regulates output regardless of which input voltage is present within range.
L6-30P locks into matching receptacle: UPS can be physically moved or rolled out for service. Hard-wired terminals are rated for higher current but require electrician for any move or replacement. P91 5–6 kVA shipped with L6-30P plug standard; 10 kVA hard-wired only.
X90-2S 140 kVA at 480 V three-phase. Below that, M90U-140 covers 140 kVA at 208/120 V, M90U-80 covers 80 kVA, M90U covers 15–60 kVA single enclosure.
Yes: that's the standard architecture. P91-6K with L6-30P out → metered/switched L6-30 PDU → C13/C19 servers and switches in the rack.
SLA: 4–5 years climate-controlled. Lithium (P91g Li, J90i, Li90): up to 15 years rated by XPC. When to replace UPS battery.
Yes: XPC 208/230 V series warranty terms explicitly cover USA and Canada. Ships from Canada.