Xtreme Power A60-550 550VA / 330W 120V Standby UPS | Canada | UPSPLUSBATTERY
- VA
- 550
- Watts
- 330
- Form
- Tower
- Topology
- Standby
Xtreme Power Conversion 120 V single-phase UPS — J60 and A60 standby, S71 line-interactive, P80 sinewave, T91 online, P91 / P91 Li online, J90 lithium 1U. 350 VA to 3 kVA on NEMA 5-15P / 5-20P / L5-30P plugs.
120 V single-phase is the default commercial and residential receptacle voltage across Canada. Almost all small-to-mid commercial UPS deployments — workstation, point-of-sale, server room, branch IT, network closet, edge compute — run 120 V on NEMA 5-15P (15 A), NEMA 5-20P (20 A), or NEMA L5-30P (locking 30 A) plugs. Step up to 208/230 V only when load exceeds the practical 120 V range or when the site already runs 208 V three-phase distribution.
UPSPLUSBATTERY.CA stocks the full XPC 120 V range across all topologies. For 208/230 V higher-power deployments see XPC 208/230 V UPS. For full XPC catalog see Xtreme Power Conversion.
| Topology | Series | VA range | Plug | Use |
|---|---|---|---|---|
| Standby — Lithium | J60, J60C | 350 / 600 VA | 5-15P | Digital signage, kiosk, POS, edge networking |
| Standby — SLA | A60 | 550 / 850 VA | 5-15P | Workstation, small office |
| Line-interactive — Tower | S71 | 700 / 1000 / 1500 VA | 5-15P | Office, routers, switches |
| Line-interactive — Sinewave | P80 | 800 VA – 3 kVA | 5-15P / 5-20P | Server room, network closet |
| Online — Tower | T91 | 700 VA – 3 kVA | 5-15P / L5-20P / L5-30P | Lab, industrial, edge compute |
| Online — Rack/Tower SLA | P91 / P91c | 1 / 1.5 / 2 / 3 kVA | 5-15P / 5-20P / L5-30P | IT rack, edge data centre |
| Online — Rack/Tower Lithium | P91 Li | 1.5 / 2 / 3 kVA | 5-15P / 5-20P / L5-30P | Long-deployment, hot-ambient |
| Online — 1U Lithium | J90 | 1 / 1.5 / 2 / 3 kVA | 5-15P / 5-20P / L5-30P | Switched outlets, slim 1U |
For 230 V variants of the same families (J60i, J90i, P91g, P91g Li, T91i), see XPC 208/230 V UPS.
NEMA 5-15P (the standard 15 A wall outlet) tops out around 1500 VA continuous on a UPS — the breaker is the limiter. NEMA 5-20P (20 A, T-slot neutral) supports up to ~2200 VA. NEMA L5-30P (locking 30 A) needed for 3000 VA at 120 V. If site only has 5-15 receptacles, biggest practical UPS is ~1500 VA — for 3 kVA at 120 V either install a dedicated 30 A 120 V circuit OR step up to 208 V.
Continuous load above ~2400 W. Higher-density rack with multiple servers in one cabinet. Three-phase distribution already present. Above 3 kVA, 208/230 V is more efficient (lower line current, lower I²R loss) and the standard receptacle is L6-30 — see XPC 208/230 V UPS.
Add nameplate watts of all loads, multiply by 1.25 buffer, pick UPS whose watt rating exceeds. P91-1500 SLA delivers 1450 W; P91-1500 Li delivers 1350 W; J90-1.5KLi delivers 1350 W; T91-1500 delivers 1450 W. P80 0.9 PF — P80-3000 = 2700 W. S71 0.6 PF — S71-1500 = 900 W. Read UPS sizing guide.
SLA cartridges across A60, S71, P80, T91, P91 stocked as compatible aftermarket — same V, Ah, terminal, and connector spec as factory. 1-year UPSPLUSBATTERY warranty. Lithium packs (J60, J60C, J90, P91 Li) are factory XPC only. Browse XPC UPS replacement batteries.
5-15P / 5-20P plug-and-play. L5-30P needs dedicated 30 A 120 V circuit installed by licensed electrician per CSA. Warranty (USA and Canada) varies by series: A60 / S71 / P80 / T91 / P91 standard 3-year; J60 / J60C 5-year; J90 / J90i / P91 Li / P91g Li 6-year. Coordinated through our Canadian team. Shipped from our Canadian warehouse — see shipping policy for rates and timing. Replies within 1 business day.
NEMA 5-15P maxes out around 1500 VA continuous. Above that you either need a 5-20P (20 A) or L5-30P (30 A) circuit installed.
120 V is fine and cheap up to ~2.4 kW continuous. Above that, 208 V is more efficient (half the line current, quarter the I²R loss in the cord) and locking L6-30 receptacles are standard in rack PDUs. For a single 1U/2U server, 120 V wins on simplicity. For a full rack, 208 V wins on efficiency. XPC 208/230 V UPS.
Yes. P91 / J90 above 2200 VA include locking 5-20R or L5-30R outputs. XPDU rack PDU options pair with most XPC 120 V UPS for distribution to multiple devices.
Yes — 5-20R is mechanically compatible with both 5-15P and 5-20P. The 20 A rating just means more current available; it does not require a 5-20P UPS plug.
J60 / J60C standby (350 / 600 VA), J90 1U online (1–3 kVA), P91 Li 2U online (1.5–3 kVA). LiFePO₄ chemistry on all. XPC lithium UPS.
SLA: 4–5 years climate-controlled. Lithium: up to 15 years rated by XPC. When to replace UPS battery.
Yes — every XPC 120 V series carries factory warranty terms that explicitly cover USA and Canada. RMA does not require cross-border shipping. Shipped from our Canadian warehouse.
120V UPS systems for North American standard outlets — 5-15P, 5-20P, and L5-30P input.
Standard 120V UPS systems are the right choice when your loads run on regular wall outlets and your facility provides standard 120V/15A or 120V/20A circuits. Output receptacles match the input voltage — 5-15R for general loads or 5-20R for higher-current rack equipment.
The Xtreme Power 120V catalogue covers 350VA to 5kVA across the J60, A60, S71, P80, P91, T91, and J90 series. Standby, line-interactive, online, and lithium topologies all available.
Our Canadian team has specified APC, Eaton, Tripp Lite, Vertiv, Mitsubishi, Toshiba, CyberPower, XPC, and Delta UPS for healthcare, data centres, and government. Enquiries answered in business hours.