About this UPS
APC by Schneider Electric Back-UPS 600VA Tower UPS
| UPC | 0731304325116 |
| Tower - 10 Hour Recharge - 3.20 Minute Stand-by - 120 V Input - 120 V AC Output - Stepped Approximated Sine Wave - 5 x NEMA 5-15R, 2 x NEMA 5-15R Surge - 7 x Battery/Surge Outlet | |
| General Information | |
|---|---|
| Manufacturer: | Schneider Electric SA |
| Manufacturer Part Number: | BE600M1 |
| Manufacturer Website Address: | http://www.schneider-electric.com |
| Brand Name: | APC by Schneider Electric |
| Product Line: | Back-UPS |
| Product Name: | Back-UPS 600VA Tower UPS |
| Marketing Information: |
|
| Packaged Quantity: | 1 Each |
| Product Type: | Standby UPS | Technical Information |
| Plug/Connector Type: | NEMA 5-15P |
| Receptacle Type: | NEMA 5-15P |
| Receptacle Detail: |
|
| Number of Battery & Surge Outlets: | 7 |
| Number of Surge-only Outlets: | 2 |
| Cord Length: | 5 ft |
| Transfer Time: | 6 ms |
| Application/Usage: |
|
Power Description |
| Load Capacity (VA): | 600 VA |
| Load Capacity (Watt): | 330 W |
| Input Voltage: | 120 V |
| Input Voltage Range: | 92 V AC - 139 V AC |
| Output Voltage: | 120 V AC |
| Input Frequency: | 60 Hz |
| Output Frequency: | 60 Hz |
| Waveform Type: | Stepped Approximated Sine Wave |
| Surge Energy Rating: | 490 J | Management |
| Alarm: |
|
Controls/Indicators |
| Status Indicators: |
LED Status Display:
|
Battery Information |
| Battery Characteristics: | Maintenance-free, Sealed, Leak-proof |
| Battery Chemistry: | Lead Acid |
| Battery Energy: | 237.6 kJ |
| Backup/Run Time (Full Load): | 3.20 Minute |
| Backup/Run Time (Half Load): | 11.80 Minute |
| Typical Battery Recharge Time: | 10 Hour |
| Hot Swappable: | Yes |
| Replaceable Battery: | Yes | Environmental Conditions |
| Maximum Operating Temperature: | 104 °F (40 °C) |
| Storage Temperature: | 5 °F (-15 °C) - 113 °F (45 °C) |
| Maximum Operating Elevation: | 9842.52 ft (3000000 mm) |
| Maximum Storage Elevation: | 49212.60 ft (15000000 mm) |
| Storage Relative Humidity: | 0% - 95% |
| Sound Emission (A-Weighted): | 35 dB(A) |
| Thermal Dissipation: | 16 BTU/h | Physical Characteristics |
| Color Family: | Black |
| Product Color: | Black |
| Height: | 5.47" (139 mm) |
| Width: | 10.79" (274 mm) |
| Depth: | 4.13" (105 mm) |
| Form Factor: | Tower |
| Weight (Approximate): | 3.49 kg | Miscellaneous |
| Package Contents: |
|
| Certifications & Standards: | California (CEC) Battery Charger|cTUVus|NOM |
| Energy Star: | Yes |
| Green Premium: | Yes |
| Optimized Energy Efficiency: | Yes |
| Product Take Back Program: | Yes |
| Mercury Free: | Yes |
| RoHS Exemption Information: | https://download.schneider-electric.com/files?p_enDocType=Declaration+of+Conformity+%28Sustainability%29&p_Doc_Ref=BE600M1_ROHS_DECLARATION&p_FileName=BE600M1KIT_ROHS_DECLARATION_US.pdf |
| REACH Declaration URL: | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfReach&pid=458562998&lang=en-us |
| EU RoHS Declaration URL: | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=458562998&lang=en-us |
| Environmental Profile Availability: | https://download.schneider-electric.com/files?p_enDocType=Environmental+Disclosure&p_Doc_Ref=ENVPEP1712010_EN |
| End of Life Manual Availability: | https://download.schneider-electric.com/files?p_enDocType=Circularity+Profile&p_Doc_Ref=ENVEOLI1712010_EN |
| California Proposition 65 Warning: | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
| Energy Star URL: | https://www.energystar.gov/products/data_center_equipment/uninterruptible_power_supplies |
| Environmentally Friendly: | Yes |
| Environmental Compliance: | Restriction of Hazardous Substances (RoHS) | Warranty |
| Limited Warranty: | 3 Year |
| Additional Warranty Information: | 3 years repair or replace |
| Directly Connected Equipment Guarantee: |
|
Technical specifications
Setup checklist: after you receive your UPS →
How long it'll keep your equipment up.
Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.
Compare with alternatives
The BE600M1 side by side with UPS from other makers.
-
Xtreme Power Conversion
Xtreme Power A60-550 550 VA / 330 W Standby UPS, 120 V
Compared with BE600M1 Spec BE600M1 Xtreme Power Capacity 600 VA / 330 W 550 VA / 330 W Topology Standby Standby Form Tower Tower Input plug NEMA 5-15P NEMA 5-15P Outlets 5 × NEMA 5-15R, 2 × NEMA 5-15R (5 on battery) 5 × NEMA 5-15R, 5 × NEMA 5-15R (5 on battery) Runtime, half load 12 min 8 min Differences
- Lower VA rating: 550 VA instead of 600 VA
$168.72 -
Xtreme Power Conversion
Xtreme Power S71-700 700 VA / 420 W Line-Interactive UPS, 120 V
Compared with BE600M1 Spec BE600M1 Xtreme Power Capacity 600 VA / 330 W 700 VA / 420 W Topology Standby Line-Interactive Form Tower Tower Input plug NEMA 5-15P NEMA 5-15P Outlets 5 × NEMA 5-15R, 2 × NEMA 5-15R (5 on battery) 4 × NEMA 5-15R Runtime, half load 12 min 6 min Differences
- 4 battery-backed outlets instead of 5
- Line-interactive, a step up from standby
- Larger unit: 420 W instead of 330 W
$243.57
Check outlets and the runtime your load needs before ordering. Questions? Call 438-881-3363 or ask for a quote.
Replacement batteries that fit this exact UPS
A line-interactive UPS typically needs new batteries every 3 to 5 years. Matching replacement cartridges are listed by UPS model; confirm the exact model before ordering.
Questions before you buy
How do I know this UPS will run my equipment?
Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating (not VA) is the number that matters. Aim for the UPS to run at 60 to 70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list; we'll respond within one business day with sizing guidance.
What's covered by the warranty, and how long does it last?
New units carry the warranty coverage stated by the manufacturer; see the product listing or manufacturer documentation for the applicable terms. Refurbished units are covered by the 1-year UPSPLUSBATTERY warranty handled in Canada.
Can I extend runtime beyond what's shown above?
Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model; contact us if you don't see the right XBP in our catalogue.