Skip to product information
1 of 3

CyberPower

CyberPower PR2200RTXL2UHVAN 2200 VA / 2200 W Rack/Tower Line-Interactive UPS

CyberPower PR2200RTXL2UHVAN 2200 VA / 2200 W Rack/Tower Line-Interactive UPS

Regular price $2,564.99 CAD
Regular price Sale price $2,564.99 CAD
Sale Sold out

Available on order

Shipping calculated at checkout.
Quantity

Available on order

Request a configured quoteCheck this UPS for your load

Local pickup: available in the Montreal area, Quebec, by appointment. Call 438-881-3363 first.

Buying 5 or more? Request volume pricing →

  • Prices in CAD. Shipping is available across Canada; see the shipping policy for rates and timing.
  • New in box: manufacturer warranty applies
  • Have a purchase order? Request a quote.

Questions? 438-881-3363 · Mon to Fri

View full details
Product details

About this UPS

The CyberPower PR2200RTXL2UHVAN is a 2200VA / 2200W rack/tower line interactive UPS from CyberPower's professional power-protection range. Engineered for reliable battery backup, voltage regulation, and surge protection in home office, business, and IT environments, backed by the full CyberPower manufacturer warranty.

Specifications

Output Capacity (VA) 2200 VA
Output Power (Watts) 2200 W
Topology Line Interactive
Output Waveform Sine Wave
Output Voltage 240 VAC
Outlets 4 × NEMA 6-20R; 2 × NEMA L6-20R
Form Factor Rack/Tower
Connectivity USB, Serial, Dry Contact
Warranty 3 Years Limited
Weight 42 kg (92.6 lb)
UPC 649532930104
Manufacturer Part Number PR2200RTXL2UHVAN
Specifications

Technical specifications

Power
VA Rating
2200VA
Wattage
2200W
Topology
Line-Interactive
Waveform
Pure Sine Wave
Input
Input Voltage
208/240V (Auto-sensing)
Input Plug
NEMA L6-20P (240V 20A)
Input Phase
Single-phase
Output
Output Voltage
200/208/220/230/240 VAC ± 5%
Receptacles
4× NEMA 6-20R2× NEMA L6-20R
Features
Form Factor
Tower/Rack Convertible
Rack Units
2U
Connectivity
USBRS-232 SerialRelay Contacts
Network Card Installed
Yes
Extended Runtime Capable
Yes
Condition
New
Operating Temperature
32 – 104 °F (0 – 40 °C)
Dimensions
434 × 630 × 86.4 mm (17.1 × 24.8 × 3.4 in) W × D × H
Weight
42.0kg
Certifications
UL1778FCC DOC Class ACECCE
Manufacturer Warranty
3 Year Limited Warranty

Setup checklist: after you receive your UPS →
Backup runtime

How long it'll keep your equipment up.

Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.

Half load (1100 W) 15 min
Full load (2200 W) 5.3 min

Need more runtime? This UPS accepts external battery packs (XBPs). Contact us about XBP options →

W
Estimated runtime …min

Estimate based on manufacturer-specified runtime curve. Real-world runtime varies with battery age, ambient temperature, and load profile.

Other makers

Compare with alternatives

The PR2200RTXL2UHVAN side by side with UPS from other makers.

  • Compared with PR2200RTXL2UHVAN
    SpecPR2200RTXL2UHVANXtreme Power
    Capacity 2200 VA / 2200 W 3000 VA / 2700 W
    Topology Line-Interactive Line-Interactive
    Form Tower/Rack Convertible, 2U Tower/Rack Convertible, 2U
    Input plug NEMA L6-20P NEMA L6-20P
    Outlets 4 × NEMA 6-20R, 2 × NEMA L6-20R 1 × IEC 60320 C19, 8 × IEC 60320 C13
    Runtime, half load 15 min 8 min

    Differences

    • No L6-20R outlet
    • No NEMA 6-20R outlet
    • Larger unit: 2700 W instead of 2200 W
    $2,198.13
  • Compared with PR2200RTXL2UHVAN
    SpecPR2200RTXL2UHVANXtreme Power
    Capacity 2200 VA / 2200 W 3000 VA / 3000 W
    Topology Line-Interactive Online Double-Conversion
    Form Tower/Rack Convertible, 2U Tower/Rack Convertible, 2U
    Input plug NEMA L6-20P NEMA L6-20P
    Outlets 4 × NEMA 6-20R, 2 × NEMA L6-20R 1 × IEC 60320 C19, 8 × IEC 60320 C13
    Runtime, half load 15 min 10 min

    Differences

    • No L6-20R outlet
    • No NEMA 6-20R outlet
    • Online double-conversion, a step up from line-interactive
    • Larger unit: 3000 W instead of 2200 W
    $3,064.32
  • Compared with PR2200RTXL2UHVAN
    SpecPR2200RTXL2UHVANXtreme Power
    Capacity 2200 VA / 2200 W 3000 VA / 2700 W
    Topology Line-Interactive Online Double-Conversion
    Form Tower/Rack Convertible, 2U Tower/Rack Convertible, 2U
    Input plug NEMA L6-20P NEMA L6-20P
    Outlets 4 × NEMA 6-20R, 2 × NEMA L6-20R 1 × IEC 60320 C19, 8 × IEC 60320 C13
    Runtime, half load 15 min 23 min

    Differences

    • No L6-20R outlet
    • No NEMA 6-20R outlet
    • No external battery option
    • Online double-conversion, a step up from line-interactive
    $5,822.09

Check outlets and the runtime your load needs before ordering. Questions? Call 438-881-3363 or ask for a quote.

Shipped across Canada
Shipping is available across Canada. See the shipping policy for rates and timing.
Manufacturer-backed
New UPS units carry the warranty coverage stated by the manufacturer. See the product listing or manufacturer documentation for the applicable terms.
In business since 2012
UPSPLUSBATTERY has supplied Canadian UPS systems since 2012.
Sizing & install help
Email your load profile and we'll spec the right UPS within one business day.
When the batteries fail

Replacement batteries that fit this exact UPS

A line-interactive UPS typically needs new batteries every 3 to 5 years. Matching replacement cartridges are listed by UPS model; confirm the exact model before ordering.

Bookmark this page before you need it.
Frequently asked

Questions before you buy

How do I know this UPS will run my equipment?

Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating (not VA) is the number that matters. Aim for the UPS to run at 60 to 70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list; we'll respond within one business day with sizing guidance.

What's covered by the warranty, and how long does it last?

New units carry the warranty coverage stated by the manufacturer; see the product listing or manufacturer documentation for the applicable terms. Refurbished units are covered by the 1-year UPSPLUSBATTERY warranty handled in Canada.

Can I extend runtime beyond what's shown above?

Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model; contact us if you don't see the right XBP in our catalogue.