Tripp Lite SmartPro SMX700HG 700 VA / 450 W Tower Line-Interactive UPS 230 V
- Power
- 700 VA / 450 W
- Form
- Tower
- Outlets
- 6× IEC 60320 C13
Tripp Lite's OMNIX350HG offers medical-grade UPS protection with built-in line interactive voltage regulation, intelligent monitoring and unattended shutdown capability. IEC320 plug & outlets, plus built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise. Tested to CE/IEC 60601-1 as medical electrical equipment. 350VA power handling capacity supports computers, inter-networking equipment and other critical loads during commercial power failures. Line interactive voltage regulation corrects brownouts as low as 159V back to normal 230V levels, saving battery reserves for use only during complete power failures. Includes, 2 line phone surge suppression and built-in USB communications port that works with PowerAlert Software and cabling to provide automatic unattended shutdown of connected network and PC applications.
| PRODUCT SPECIFICATIONS | |
|---|---|
| Receptacle Detail | 6 |
| Transfer Time | 5 ms |
| Load Capacity (VA) | 350 VA |
| Load Capacity (Watt) | 225 W |
| Input Voltage | 220 V AC |
| Input Current | 1.80 A |
| Output Voltage | 230 V AC |
| USB | Yes |
| Backup/Run Time (Full Load) | 15.50 Minute |
| Backup/Run Time (Half Load) | 37 Minute |
| Battery Life | 6 Year |
| Typical Battery Recharge Time | 7.20 Hour |
| Hot Swappable | Yes |
| Height | 10.60" (269.24 mm) |
| Width | 5.20" (132.08 mm) |
| Depth | 7.40" (187.96 mm) |
| Form Factor | Tower |
| Weight (Approximate) | 25.40 lb (11521.25 g) |
| Package Contents |
|
| Additional Information |
|
| Certifications & Standards | Tested to CE/ IEC 60601-1 (Series AGOM6832), Class B (emissions) |
| Country of Origin | China |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Limited Warranty | 2 Year |
Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.
A line-interactive UPS typically needs new batteries every 3 to 5 years. Matching replacement cartridges are listed by UPS model; confirm the exact model before ordering.
Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating (not VA) is the number that matters. Aim for the UPS to run at 60 to 70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list; we'll respond within one business day with sizing guidance.
New units carry the warranty coverage stated by the manufacturer; see the product listing or manufacturer documentation for the applicable terms. Refurbished units are covered by the 1-year UPSPLUSBATTERY warranty handled in Canada.
Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model; contact us if you don't see the right XBP in our catalogue.