About this UPS
- Power Device: Small workgroup server
- Battery: 2
- Networking: RS-232, USB
- Expansion / Connectivity: 1 x management (RS-232) - RJ-45
- Mfr. # 5P750
- UNSPSC: 43170000
Eaton 5P 750 Tower - UPS - AC 120 V - 600 Watt - 750 VA 7 Ah - RS-232, USB - output connectors: 8 - black, silver
| General | |
|---|---|
| Device Type | UPS - external |
| Color | Black, silver |
| Power Device | |
|---|---|
| Load Rating | Small workgroup server |
| UPS Technology | Line interactive |
| Input Voltage | AC 120 V |
| Input Voltage Range | AC 89 - 151 V |
| Input Voltage Range (Adjustable) | AC 70 - 153 V |
| Frequency Provided | 50/60 Hz |
| Frequency Required | 50/60 Hz |
| Input Connectors | Power NEMA 5-15 |
| Power Output Connectors Details | 8 x power NEMA 5-15 |
| Output Voltage | AC 120 V 50/60 Hz |
| Power Capacity | 600 Watt / 750 VA |
| Efficiency | 97% |
| Battery | |
|---|---|
| Quantity | 2 |
| Technology | Lead acid |
| Voltage Provided | 12 V |
| Capacity | 7 Ah |
| Run Time (Up To) | 4 min at full load | 12 min at half load |
| Networking | |
|---|---|
| Remote Management Interface | RS-232, USB |
| Expansion / Connectivity | |
|---|---|
| Interfaces | 1 x management (RS-232) - RJ-45 | 1 x management (USB) - 4 pin USB Type B |
| Expansion Slots | 1 (total) / 1 (free) x expansion slot |
| Miscellaneous | |
|---|---|
| Cables Included | USB cable - external - 6 ft | Serial cable - external - 6 ft | Power cable - integrated - 6 ft |
| Features | Advance Battery Management (ABM), LCD display, remote ON/OFF function, Remote Emergency Power Off (REPO), hot-swappable batteries |
| Compliant Standards | CISPR 22 Class B, UL 1778, UL 497A, EN55024, FCC Part 15 B, IEC 62040-2, RoHS, cULus |
| Software / System Requirements | |
|---|---|
| Software Included | Intelligent Power Software Suite |
| Environmental Standards | |
|---|---|
| ENERGY STAR | Yes |
| Manufacturer Warranty | |
|---|---|
| Service & Support | Limited warranty - 3 years |
| Environmental Parameters | |
|---|---|
| Min Operating Temperature | 32 Ã¥ ¡F |
| Max Operating Temperature | 95 Ã¥ ¡F |
| Humidity Range Operating | 0 - 90% (non-condensing) |
| Sound Emission | 45 dB |
| Dimensions & Weight | |
|---|---|
| Width | 5.9 in |
| Depth | 13.6 in |
| Height | 9.1 in |
| Weight | 23.61 lbs |
Technical specifications
How long it'll keep your equipment up.
Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.
Estimate based on manufacturer-specified runtime curve. Real-world runtime varies with battery age, ambient temperature, and load profile.
Before you order
How do I know this UPS will run my equipment?
Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating — not VA — is the number that matters. Aim for the UPS to run at 60–70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list and we'll size the right UPS within one business hour.
What's covered by the warranty, and how long does it last?
New units carry the full manufacturer warranty registered to you on receipt. The manufacturer handles claims directly via their North American support channel. Refurbished units are covered by our own 1-year UPSPLUSBATTERY warranty handled in-house in Canada.
Can I extend runtime beyond what's shown above?
Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model — contact us if you don't see the right XBP in our catalogue.