About this UPS
Tripp Lite SMART1500RMXL2U UPS
| UPC | 0037332120403 |
| 1500VA/940W - 12 Minute Full Load - 8 x NEMA 5-15R | |
| General Information | |
|---|---|
| Manufacturer: | Tripp Lite by Eaton |
| Manufacturer Part Number: | SMART1500RMXL2U |
| Manufacturer Website Address: | https://tripplite.eaton.com/ |
| Brand Name: | Tripp Lite series |
| Product Line: | SmartPro |
| Product Name: | SMART1500RMXL2U UPS |
| Marketing Information: |
1.44kVA/1.44kW/120V Battery Backup for Distributed IT, Telecom or Enterprise Deployments This rack-mount line-interactive UPS system provides reliable battery backup and AC power protection against blackouts, brownouts, surges and line noise that can damage your valuable IT equipment or destroy data. The SMART1500RMXL2U is ideal power management for high-end in-rack networking equipment, including servers, VoIP phones, data storage and PoE switches. Unity power factor ensures the most watts possible at each power rating, so you can connect more equipment. Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages Optional LX Platform Network Management Card Allows Remote Access 24/7 NEMA 5-15R Outlets Protect Your Connected Components Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions |
| Product Type: | Line-interactive UPS | Technical Information |
| AVR: | Yes |
| Plug/Connector Type: | NEMA 5-15P |
| Receptacle Type: | NEMA 5-15R |
| Receptacle Detail: | 8 x NEMA 5-15R |
| Emergency Power OFF: | Yes |
| Cord Length: | 10 ft |
| Transfer Time: | 4 ms |
| EMI/RFI Noise Filter: | Yes |
| Phase: | Single Phase |
| Energy Saving: | Greater than 95% efficiency - GREEN UPS; Individually controllable load banks |
| Application/Usage: |
|
Power Description |
| Load Capacity (VA): | 1.44 kVA |
| Load Capacity (Watt): | 1.44 kW |
| Input Voltage: | 120 V AC |
| Output Voltage: |
|
| Input Frequency: | 60 Hz |
| Output Frequency: | 60 Hz |
| Waveform Type: | Sine Wave |
| Output Power Factor: | 1 | Management |
| Network Management: | SNMP Manageable |
| Alarm: |
|
Controls/Indicators |
| Status Indicators: |
|
Interfaces/Ports |
| USB: | Yes |
| EPO Port: | Yes |
| Total Number of Expansion Slots: | 1 | Battery Information |
| DC System Voltage: | 48 V DC |
| Battery Characteristics: | Valve-regulated |
| Battery Chemistry: | Lead Acid |
| Backup/Run Time (Full Load): | 5.10 Minute |
| Backup/Run Time (Half Load): | 15.10 Minute |
| Battery Life: | 6 Year |
| Typical Battery Recharge Time: | 4 Hour |
| Hot Swappable: | Yes |
| Replaceable Battery: | Yes | Environmental Conditions |
| Maximum Operating Temperature: | 104 °F (40 °C) |
| Storage Temperature: | 5 °F (-15 °C) - 122 °F (50 °C) |
| Sound Emission (A-Weighted): | 40 dB(A) | Physical Characteristics |
| Height: | 3.45" (87.63 mm) |
| Width: | 17.20" (436.88 mm) |
| Depth: | 17.60" (447.04 mm) |
| Rack Height: | 2U |
| Form Factor: | Rack/Tower |
| Weight (Approximate): | 23 kg | Miscellaneous |
| Package Contents: |
|
| Additional Information: |
|
| Certifications & Standards: | UL1778 (USA), cUL (Canada), FCC Class A (emissions), NOM (Mexico), Conforms to IEEE 587 / ANSI C62.41 specifications |
| Country of Origin: | China | Warranty |
| Limited Warranty: | 3 Year |
| Additional Warranty Information: | 3 year with registration. Note: Registration is required for 3-year warranty. |
Technical specifications
How long it'll keep your equipment up.
Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.
Need more runtime? This UPS accepts external battery packs (XBPs). Contact us about XBP options →
Estimate based on manufacturer-specified runtime curve. Real-world runtime varies with battery age, ambient temperature, and load profile.
Compatible accessories
Network management cards, rail kits, environmental sensors — verified compatible with this UPS line.
Replacement batteries that fit this exact UPS
A line-interactive UPS typically needs new batteries every 3–5 years. We stock the matching replacement cartridges — Canadian warranty.
Before you order
How do I know this UPS will run my equipment?
Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating — not VA — is the number that matters. Aim for the UPS to run at 60–70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list and we'll size the right UPS within one business hour.
What's covered by the warranty, and how long does it last?
New units carry the full manufacturer warranty registered to you on receipt. The manufacturer handles claims directly via their North American support channel. Refurbished units are covered by our own 1-year UPSPLUSBATTERY warranty handled in-house in Canada.
Can I extend runtime beyond what's shown above?
Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model — contact us if you don't see the right XBP in our catalogue.