APC

APC Smart-UPS SMT1500NC 1500 VA / 1000 W Tower UPS with Network Card, 120 V

APC Smart-UPS SMT1500NC 1500 VA / 1000 W Tower UPS with Network Card, 120 V

Discontinued by the manufacturerManufacturer’s current model: SMT1500CNC. This listing is the earlier model.
Regular price $2,093.00 CAD
Regular price Sale price $2,093.00 CAD
Sale Sold out

Available on order

Shipping calculated at checkout.
Quantity

Available on order

Request a configured quoteCheck this UPS for your load

Local pickup: available in the Montreal area, Quebec, by appointment. Call 438-881-3363 first.

Buying 5 or more? Request volume pricing →

  • Prices in CAD. Shipping is available across Canada; see the shipping policy for rates and timing.
  • New in box: manufacturer warranty applies
  • Have a purchase order? Request a quote.

Questions? 438-881-3363 · Mon to Fri

View full details
Product details

About this UPS

The APC SMT1500NC is a 1440VA / 1000W tower line-interactive UPS. Designed for business-critical power protection, it delivers clean, regulated output to protect servers, network equipment, workstations, and other sensitive electronics from power disturbances.

Specifications

Output Capacity (VA) 1440 VA
Output Power (Watts) 1000 W
Topology Line-Interactive
Output Waveform Pure Sine Wave
Output Voltage 120V
Input Plug NEMA 5-15P
Outlets 8 × NEMA 5-15R
Form Factor Tower
Communications USB, RS-232 Serial
Weight 24.13 kg (53.2 lb)
Manufacturer Part Number SMT1500NC

APC Smart-UPS SMT1500 battery replacement: the five stages (3-minute video)

The SMT1500NC takes one RBC7. We stock it two ways: the battery set you wire yourself or the pre-assembled pack.

Chapters and transcript
  • 0:00 Which battery fits the APC Smart-UPS 1500?
  • 0:34 What do you need?
  • 0:52 What does the manual say before you start?
  • 1:23 How does the five-stage swap work?
  • 1:56 The self-test and the two symptoms
  • 2:35 Where do you buy it in Canada?

1 An APC Smart-UPS 1500 tower is due for a battery. The SMT1500C models, and the older SMT1500US, all take one RBC7. That is one cartridge: a 24 volt, 17 amp hour sealed lead acid pack, in a 1500 volt-amp, 1000 watt line-interactive tower. This video shows what the cartridge is, what APC's manual says before you start, the swap in the manual's order, and the test after. The RBC7 comes two ways from UPSPLUSBATTERY. A loose set: two new batteries that reuses your existing wiring. Or a pre-assembled cartridge, wired with its harness, ready to drop in: plug and play. Both link below. You need a few minutes, work gloves, and a flat surface. Nothing else. These are illustrations. Follow your UPS's manual. APC's manual is specific. Replace the battery with the same number and type. Replace it at least every five years, or when the UPS says the battery needs replacement. Take off rings and watches first: a battery terminal shorted by metal can cause severe burns. And never put a battery in the fire. Heat, poor utility power, and frequent short outages all cut battery life. Old batteries get recycled; the new cartridge ships with a disposal sheet. The battery sits behind the battery compartment bezel. The swap has five stages. One: power everything down and unplug the UPS. Two: unclip the battery compartment bezel and lift it away. Three: swap the pack. Lift out the old cartridge and drop in the new one. Four: close it up, connector locked, bezel back on. Five: recharge before full runtime. The RBC7 instruction sheet carries the exact steps, in APC's order. If the cartridge is a loose set, connect the wires before you close up, red and black in the same spots. Run the self-test from the panel. In the About menu you will find the predictive battery replacement date; check it reflects the new battery. The UPS also runs its own self-tests, on a schedule you can set. APC's guide covers the two symptoms you might see next. If the battery warning light beeps one minute every five hours, that means a weak charge: let it recharge for at least four hours, then run the self-test again. If it still flags, replace the battery. A flashing light with a beep every two seconds means the connector is not fully seated. Power down, push it back in until it locks, and test again. Expect a full charge before you expect full runtime. The RBC7 is linked below, in both formats. UPSPLUSBATTERY ships UPS batteries across Canada from Montreal. UPSPLUSBATTERY ships across Canada. The battery is linked below.

Specifications

Technical specifications

Power
VA Rating
1440VA
Wattage
1000W
Topology
Line-Interactive
Waveform
Pure Sine Wave
Input
Input Voltage
120V
Input Plug
NEMA 5-15P (standard 15A)
Input Phase
Single-phase
Output
Output Voltage
120V
Receptacles
8× NEMA 5-15R
Features
Form Factor
Tower
Connectivity
USBRS-232 Serial
Network Card Installed
Yes
Extended Runtime Capable
No
Condition
New
Dimensions
219 × 171 × 439 mm (8.62 × 6.73 × 17.28 in)
Weight
24.13kg
Manufacturer Warranty
3 years

Setup checklist: after you receive your UPS →
Backup runtime

How long it'll keep your equipment up.

Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.

Half load (500 W) 23 min
Full load (1000 W) 6.5 min
W
Estimated runtime …min

Estimate based on manufacturer-specified runtime curve. Real-world runtime varies with battery age, ambient temperature, and load profile.

Discontinued by the manufacturer

Available now

The manufacturer no longer makes the SMT1500NC. These UPS are sold today; each card compares one with the discontinued model.

  • Compared with SMT1500NC
    SpecSMT1500NCXtreme Power
    Capacity 1440 VA / 1000 W 1100 VA / 990 W
    Topology Line-Interactive Line-Interactive
    Form Tower Tower/Rack Convertible, 2U
    Input plug NEMA 5-15P NEMA 5-15P
    Outlets 8 × NEMA 5-15R 8 × NEMA 5-15R
    Runtime, half load 23 min 11 min

    Differences

    • Slightly lower rating: 990 W instead of 1000 W
    • Network card not included
    • Lower VA rating: 1100 VA instead of 1440 VA
    $1,096.42
  • Compared with SMT1500NC
    SpecSMT1500NCXtreme Power
    Capacity 1440 VA / 1000 W 1000 VA / 1000 W
    Topology Line-Interactive Online Double-Conversion
    Form Tower Tower/Rack Convertible, 2U
    Input plug NEMA 5-15P NEMA 5-15P
    Outlets 8 × NEMA 5-15R 8 × NEMA 5-15R
    Runtime, half load 23 min 10 min

    Differences

    • Network card not included
    • Lower VA rating: 1000 VA instead of 1440 VA
    • Online double-conversion, a step up from line-interactive
    $1,346.27
  • Compared with SMT1500NC
    SpecSMT1500NC360PQ
    Capacity 1440 VA / 1000 W 1000 VA / 1000 W
    Topology Line-Interactive Online Double-Conversion
    Form Tower Tower/Rack Convertible, 2U
    Input plug NEMA 5-15P NEMA 5-15P
    Outlets 8 × NEMA 5-15R 8 × NEMA 5-15R
    Runtime, half load 23 min 12 min

    Differences

    • Network card not included
    • Lower VA rating: 1000 VA instead of 1440 VA
    • Online double-conversion, a step up from line-interactive
    $1,137.00

Check outlets and the runtime your load needs before ordering. Questions? Call 438-881-3363 or ask for a quote.

Shipped across Canada
Shipping is available across Canada. See the shipping policy for rates and timing.
Manufacturer-backed
New UPS units carry the warranty coverage stated by the manufacturer. See the product listing or manufacturer documentation for the applicable terms.
In business since 2012
UPSPLUSBATTERY has supplied Canadian UPS systems since 2012.
Sizing & install help
Email your load profile and we'll spec the right UPS within one business day.
When the batteries fail

Replacement batteries that fit this exact UPS

A line-interactive UPS typically needs new batteries every 3 to 5 years. Matching replacement cartridges are listed by UPS model; confirm the exact model before ordering.

Bookmark this page before you need it.
Frequently asked

Questions before you buy

How do I know this UPS will run my equipment?

Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating (not VA) is the number that matters. Aim for the UPS to run at 60 to 70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list; we'll respond within one business day with sizing guidance.

What's covered by the warranty, and how long does it last?

New units carry the warranty coverage stated by the manufacturer; see the product listing or manufacturer documentation for the applicable terms. Refurbished units are covered by the 1-year UPSPLUSBATTERY warranty handled in Canada.

Can I extend runtime beyond what's shown above?

Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model; contact us if you don't see the right XBP in our catalogue.