APC Smart-UPS SMT1500CNC 1500 VA / 1000 W Tower Line-Interactive UPS
- Power
- 1440 VA / 1000 W
- Form
- Tower
- Outlets
- 8× NEMA 5-15R
The APC SMT1500NC is a 1440VA / 1000W tower line-interactive UPS. Designed for business-critical power protection, it delivers clean, regulated output to protect servers, network equipment, workstations, and other sensitive electronics from power disturbances.
| Output Capacity (VA) | 1440 VA |
| Output Power (Watts) | 1000 W |
| Topology | Line-Interactive |
| Output Waveform | Pure Sine Wave |
| Output Voltage | 120V |
| Input Plug | NEMA 5-15P |
| Outlets | 8 × NEMA 5-15R |
| Form Factor | Tower |
| Communications | USB, RS-232 Serial |
| Weight | 24.13 kg (53.2 lb) |
| Manufacturer Part Number | SMT1500NC |
The SMT1500NC takes one RBC7. We stock it two ways: the battery set you wire yourself or the pre-assembled pack.
1 An APC Smart-UPS 1500 tower is due for a battery. The SMT1500C models, and the older SMT1500US, all take one RBC7. That is one cartridge: a 24 volt, 17 amp hour sealed lead acid pack, in a 1500 volt-amp, 1000 watt line-interactive tower. This video shows what the cartridge is, what APC's manual says before you start, the swap in the manual's order, and the test after. The RBC7 comes two ways from UPSPLUSBATTERY. A loose set: two new batteries that reuses your existing wiring. Or a pre-assembled cartridge, wired with its harness, ready to drop in: plug and play. Both link below. You need a few minutes, work gloves, and a flat surface. Nothing else. These are illustrations. Follow your UPS's manual. APC's manual is specific. Replace the battery with the same number and type. Replace it at least every five years, or when the UPS says the battery needs replacement. Take off rings and watches first: a battery terminal shorted by metal can cause severe burns. And never put a battery in the fire. Heat, poor utility power, and frequent short outages all cut battery life. Old batteries get recycled; the new cartridge ships with a disposal sheet. The battery sits behind the battery compartment bezel. The swap has five stages. One: power everything down and unplug the UPS. Two: unclip the battery compartment bezel and lift it away. Three: swap the pack. Lift out the old cartridge and drop in the new one. Four: close it up, connector locked, bezel back on. Five: recharge before full runtime. The RBC7 instruction sheet carries the exact steps, in APC's order. If the cartridge is a loose set, connect the wires before you close up, red and black in the same spots. Run the self-test from the panel. In the About menu you will find the predictive battery replacement date; check it reflects the new battery. The UPS also runs its own self-tests, on a schedule you can set. APC's guide covers the two symptoms you might see next. If the battery warning light beeps one minute every five hours, that means a weak charge: let it recharge for at least four hours, then run the self-test again. If it still flags, replace the battery. A flashing light with a beep every two seconds means the connector is not fully seated. Power down, push it back in until it locks, and test again. Expect a full charge before you expect full runtime. The RBC7 is linked below, in both formats. UPSPLUSBATTERY ships UPS batteries across Canada from Montreal. UPSPLUSBATTERY ships across Canada. The battery is linked below.
Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.
The manufacturer no longer makes the SMT1500NC. These UPS are sold today; each card compares one with the discontinued model.
| Spec | SMT1500NC | Xtreme Power |
|---|---|---|
| Capacity | 1440 VA / 1000 W | 1100 VA / 990 W |
| Topology | Line-Interactive | Line-Interactive |
| Form | Tower | Tower/Rack Convertible, 2U |
| Input plug | NEMA 5-15P | NEMA 5-15P |
| Outlets | 8 × NEMA 5-15R | 8 × NEMA 5-15R |
| Runtime, half load | 23 min | 11 min |
Differences
| Spec | SMT1500NC | Xtreme Power |
|---|---|---|
| Capacity | 1440 VA / 1000 W | 1000 VA / 1000 W |
| Topology | Line-Interactive | Online Double-Conversion |
| Form | Tower | Tower/Rack Convertible, 2U |
| Input plug | NEMA 5-15P | NEMA 5-15P |
| Outlets | 8 × NEMA 5-15R | 8 × NEMA 5-15R |
| Runtime, half load | 23 min | 10 min |
Differences
| Spec | SMT1500NC | 360PQ |
|---|---|---|
| Capacity | 1440 VA / 1000 W | 1000 VA / 1000 W |
| Topology | Line-Interactive | Online Double-Conversion |
| Form | Tower | Tower/Rack Convertible, 2U |
| Input plug | NEMA 5-15P | NEMA 5-15P |
| Outlets | 8 × NEMA 5-15R | 8 × NEMA 5-15R |
| Runtime, half load | 23 min | 12 min |
Differences
Check outlets and the runtime your load needs before ordering. Questions? Call 438-881-3363 or ask for a quote.
The manufacturer no longer makes the SMT1500NC. These UPS are sold today; each card compares one with the discontinued model.
Questions? Call 438-881-3363 or ask for a quote.
Only accessories the manufacturer lists for this model.
A line-interactive UPS typically needs new batteries every 3 to 5 years. Matching replacement cartridges are listed by UPS model; confirm the exact model before ordering.
Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating (not VA) is the number that matters. Aim for the UPS to run at 60 to 70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list; we'll respond within one business day with sizing guidance.
New units carry the warranty coverage stated by the manufacturer; see the product listing or manufacturer documentation for the applicable terms. Refurbished units are covered by the 1-year UPSPLUSBATTERY warranty handled in Canada.
Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model; contact us if you don't see the right XBP in our catalogue.