Eaton 9SX2000G 2000 VA / 1800 W Online UPS
- Power
- 2000 VA / 1800 W
- Form
- Tower
- Outlets
- 8× IEC 60320 C13
The Tripp Lite SUINT2000XLCD is a 2000VA / 1800W tower online double-conversion UPS from Tripp Lite by Eaton. Designed for reliable power protection, it delivers clean, regulated output to protect computers, network equipment, workstations, and other sensitive electronics from power disturbances, backed by Tripp Lite's full manufacturer warranty and Eaton's worldwide service network.
| Output Capacity (VA) | 2000 VA |
| Output Power (Watts) | 1800 W |
| Topology | Online Double-Conversion |
| Output Waveform | Pure Sine Wave |
| Output Voltage | 230 VAC |
| Form Factor | Tower |
| Communications | USB, Serial, SNMP/Network |
| Warranty | 2 Years Limited |
| Weight | 19.55 kg (43.1 lb) |
| UPC | 037332194886 |
| Manufacturer Part Number | SUINT2000XLCD |
Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.
Need more runtime? This UPS accepts external battery packs (XBPs). Contact us about XBP options →
The manufacturer no longer makes the SUINT2000XLCD. These UPS are sold today; each card compares one with the discontinued model.
| Spec | SUINT2000XLCD | Xtreme Power |
|---|---|---|
| Capacity | 2000 VA / 1800 W | 2000 VA / 2000 W |
| Topology | Online Double-Conversion | Online Double-Conversion |
| Form | Tower | Tower/Rack Convertible, 2U |
| Input plug | IEC C14 | NEMA L6-20P |
| Outlets | 7 × IEC 60320 C13 | 1 × IEC 60320 C19, 8 × IEC 60320 C13 |
| Runtime, half load | 12 min | 10 min |
Differences
| Spec | SUINT2000XLCD | Xtreme Power |
|---|---|---|
| Capacity | 2000 VA / 1800 W | 2000 VA / 1800 W |
| Topology | Online Double-Conversion | Online Double-Conversion |
| Form | Tower | Tower/Rack Convertible, 2U |
| Input plug | IEC C14 | NEMA L6-20P |
| Outlets | 7 × IEC 60320 C13 | 8 × IEC 60320 C13 |
| Runtime, half load | 12 min | 30 min |
Differences
Check outlets and the runtime your load needs before ordering. Questions? Call 438-881-3363 or ask for a quote.
The manufacturer no longer makes the SUINT2000XLCD. These UPS are sold today; each card compares one with the discontinued model.
Questions? Call 438-881-3363 or ask for a quote.
Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating (not VA) is the number that matters. Aim for the UPS to run at 60 to 70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list; we'll respond within one business day with sizing guidance.
New units carry the warranty coverage stated by the manufacturer; see the product listing or manufacturer documentation for the applicable terms. Refurbished units are covered by the 1-year UPSPLUSBATTERY warranty handled in Canada.
Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model; contact us if you don't see the right XBP in our catalogue.