About this UPS
APC Smart-UPS RT 1000VA
| UPC | 0731304205418 |
| 1000VA/700W - 10.2 Minute Full Load - 6 x IEC 320-C13, 2 | |
| General Information | |
|---|---|
| Manufacturer: | Schneider Electric SA |
| Manufacturer Part Number: | SURT1000XLI |
| Manufacturer Website Address: | http://www.schneider-electric.com |
| Brand Name: | APC by Schneider Electric |
| Product Line: | Smart-UPS |
| Product Series: | RT |
| Product Name: | Smart-UPS RT 1000VA |
| Marketing Information: | Smart-UPS RT is a family of high preformance UPSs for servers, networking equipment, telecommunication systems, industrial and medical equipment, and other mission-critical applications. Smart-UPS RT UPSs are based on the field-proven, industry-leading Smart-UPS functionality, but features double conversion on-line topology, which delivers tight voltage and frequency regulation, zero transfer time to and from battery, and input power factor correction. While offering advanced performance and high availability features, the Smart-UPS RT can be managed using PowerChute software, as well as an array of SmartSlot accessories. Smart-UPS RT provides battery back up to the load through the use of internal batteries. However, an unlimited number of external battery packs can be added to meet desired levels of runtime. All Smart-UPS RTs and battery packs ship in tower configuration, while easily converting to the 19" rack-mount mode with the addition of an APC Rail Kit. |
| Product Type: | Double Conversion Online UPS | Technical Information |
| Plug/Connector Type: | IEC 320-C14 |
| Receptacle Type: | IEC 60320 C13 |
| Receptacle Detail: |
|
| Number of Battery & Surge Outlets: | 8 |
| Bypass Switch: | Automatic |
| Emergency Power OFF: | Optional |
| Transfer Time: | 0 ns | Power Description |
| Load Capacity (VA): | 1 kVA |
| Load Capacity (Watt): | 700 W |
| Input Voltage: | 220 V AC |
| Output Voltage: | 230 V AC |
| Waveform Type: | Sine Wave |
| Surge Energy Rating: | 420 J | Management |
| Alarm: |
|
| Battery Management: | Intelligent Battery Management | Controls/Indicators |
| Status Indicators: | LED status display with load and battery bar-graphs and On Line, On Battery, Replace Battery, Overload and Bypass Indicators. | Interfaces/Ports |
| Serial Port: | Yes |
| Total Number of Expansion Slots: | 1 | Battery Information |
| Battery Characteristics: | Spill-proof, Maintenance-free |
| Battery Chemistry: | Lead Acid |
| Backup/Run Time (Full Load): | 10.20 Minute |
| Backup/Run Time (Half Load): | 24.40 Minute |
| Typical Battery Recharge Time: | 3 Hour |
| Hot Swappable: | Yes | Environmental Conditions |
| Maximum Operating Temperature: | 122 °F (50 °C) |
| Sound Emission (A-Weighted): | 50 dB(A) |
| Thermal Dissipation: | 239 BTU/h | Physical Characteristics |
| Color Family: | Black |
| Product Color: | Black |
| Height: | 3.35" (85.09 mm) |
| Width: | 17" (431.80 mm) |
| Depth: | 19" (482.60 mm) |
| Form Factor: | Tower |
| Weight (Approximate): | 22.95 kg | Miscellaneous |
| Package Contents: |
|
| Additional Information: |
|
| Certifications & Standards: |
|
| Environmentally Friendly: | Yes | Warranty |
| Limited Warranty: | 2 Year |
Technical specifications
How long it'll keep your equipment up.
Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.
Need more runtime? This UPS accepts external battery packs (XBPs). Contact us about XBP options →
Estimate based on manufacturer-specified runtime curve. Real-world runtime varies with battery age, ambient temperature, and load profile.
Compatible accessories
Network management cards, rail kits, environmental sensors — verified compatible with this UPS line.
Replacement batteries that fit this exact UPS
A line-interactive UPS typically needs new batteries every 3–5 years. We stock the matching replacement cartridges — Canadian warranty.
Before you order
How do I know this UPS will run my equipment?
Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating — not VA — is the number that matters. Aim for the UPS to run at 60–70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list and we'll size the right UPS within one business hour.
What's covered by the warranty, and how long does it last?
New units carry the full manufacturer warranty registered to you on receipt. The manufacturer handles claims directly via their North American support channel. Refurbished units are covered by our own 1-year UPSPLUSBATTERY warranty handled in-house in Canada.
Can I extend runtime beyond what's shown above?
Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model — contact us if you don't see the right XBP in our catalogue.





