APC Smart-UPS SRT SRT3000XLA 3000 VA / 2700 W Tower Online UPS, 120 V
- Power
- 3000 VA / 2700 W
- Form
- Tower
- Outlets
- 1× NEMA L5-30R, 8× NEMA 5-20R
| UPC | 0731304231479 |
| 3000VA/2100W - 14.1 Minute Full Load - 6 x NEMA 5-15R, 2 x NEMA 5-20R | |
| General Information | |
|---|---|
| Manufacturer: | Schneider Electric SA |
| Manufacturer Part Number: | SURTA3000XL |
| Manufacturer Website Address: | http://www.schneider-electric.com |
| Brand Name: | APC by Schneider Electric |
| Product Line: | Smart-UPS |
| Product Series: | RT |
| Product Model: | SURTA3000XL |
| Product Name: | Smart-UPS RT 3000VA Tower UPS |
| Marketing Information: |
A versatile UPS developed for the harshest power conditions in the world: Smart-UPS RT 3000VA Rack/Tower is a family of high-density, performance UPSs for voice and data networks, medical labs, and light industrial applications. Featuring double conversion on-line topology, the Smart-UPS RT 3000VA Rack/Tower protects your data by supplying reliable, network-grade power. Rack-optimized models are an ideal choice for space constrained environments. |
| Product Type: | Double Conversion Online UPS | Technical Information |
| Plug/Connector Type: | NEMA L5-30P |
| Receptacle Type: |
|
| Receptacle Detail: |
|
| Number of Battery & Surge Outlets: | 8 |
| Bypass Switch: | Automatic & Manual |
| Emergency Power OFF: | Yes |
| Cord Length: | 10 ft | Power Description |
| Load Capacity (VA): | 3 kVA |
| Load Capacity (Watt): | 2.10 kW |
| Input Voltage: | 110 V AC |
| Output Voltage: | 120 V AC |
| Waveform Type: | Sine Wave |
| Surge Energy Rating: | 480 J | Management |
| Alarm: |
|
| Battery Management: | Intelligent battery management | Controls/Indicators |
| Status Indicators: |
LED display with load and battery bar-graphs:
|
Interfaces/Ports |
| Serial Port: | Yes |
| Total Number of Expansion Slots: | 1 | Battery Information |
| Battery Characteristics: | Maintenance-free |
| Battery Chemistry: | Lead Acid |
| Backup/Run Time (Full Load): | 14.10 Minute |
| Backup/Run Time (Half Load): | 33.90 Minute |
| Hot Swappable: | Yes | Environmental Conditions |
| Maximum Operating Temperature: | 113 °F (45 °C) |
| Thermal Dissipation: | 655 BTU/h | Physical Characteristics |
| Color Family: | Black |
| Product Color: | Black |
| Height: | 5" (127 mm) |
| Width: | 17" (431.80 mm) |
| Depth: | 26" (660.40 mm) |
| Form Factor: | Tower |
| Weight (Approximate): | 54.43 kg | Miscellaneous |
| Package Contents: |
|
| Additional Information: |
|
| Certifications & Standards: |
|
| Environmentally Friendly: | Yes | Warranty |
| Limited Warranty: | 2 Year |
Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.
Need more runtime? This UPS accepts external battery packs (XBPs). Contact us about XBP options →
The manufacturer no longer makes the SURTA3000XL. These UPS are sold today; each card compares one with the discontinued model.
| Spec | SURTA3000XL | Delta |
|---|---|---|
| Capacity | 3000 VA / 2100 W | 3000 VA / 2700 W |
| Topology | Online Double-Conversion | Online Double-Conversion |
| Form | Tower | Tower/Rack Convertible, 2U |
| Input plug | NEMA L5-30P | NEMA L5-30P |
| Outlets | 6 × NEMA 5-15R, 2 × NEMA 5-20R | 8 × NEMA 5-15/20R, 1 × NEMA L5-30R |
| Runtime, half load | 30 min | 11 min |
Differences
| Spec | SURTA3000XL | Xtreme Power |
|---|---|---|
| Capacity | 3000 VA / 2100 W | 3000 VA / 2880 W |
| Topology | Online Double-Conversion | Online Double-Conversion |
| Form | Tower | Tower |
| Input plug | NEMA L5-30P | NEMA L5-30P |
| Outlets | 6 × NEMA 5-15R, 2 × NEMA 5-20R | 1 × NEMA L5-30R, 8 × NEMA 5-20R |
| Runtime, half load | 30 min | 10 min |
Differences
| Spec | SURTA3000XL | Xtreme Power |
|---|---|---|
| Capacity | 3000 VA / 2100 W | 3000 VA / 2880 W |
| Topology | Online Double-Conversion | Online Double-Conversion |
| Form | Tower | Tower/Rack Convertible, 2U |
| Input plug | NEMA L5-30P | NEMA L5-30P |
| Outlets | 6 × NEMA 5-15R, 2 × NEMA 5-20R | 1 × NEMA L5-30R, 6 × NEMA 5-15/20R |
| Runtime, half load | 30 min | 10 min |
Differences
Check outlets and the runtime your load needs before ordering. Questions? Call 438-881-3363 or ask for a quote.
The manufacturer no longer makes the SURTA3000XL. These UPS are sold today; each card compares one with the discontinued model.
Questions? Call 438-881-3363 or ask for a quote.
Only accessories the manufacturer lists for this model.
A line-interactive UPS typically needs new batteries every 3 to 5 years. Matching replacement cartridges are listed by UPS model; confirm the exact model before ordering.
Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating (not VA) is the number that matters. Aim for the UPS to run at 60 to 70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list; we'll respond within one business day with sizing guidance.
New units carry the warranty coverage stated by the manufacturer; see the product listing or manufacturer documentation for the applicable terms. Refurbished units are covered by the 1-year UPSPLUSBATTERY warranty handled in Canada.
Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model; contact us if you don't see the right XBP in our catalogue.