Tripp Lite SmartPro SMART2200RM2U 1950 VA / 1950 W Rack/Tower UPS
- Power
- 1950 VA / 1950 W
- Form
- Tower/Rack Convertible
- Outlets
- 6× NEMA 5-20R, 1× NEMA L5-20R
| UPC | 0037332125774 |
| 2200VA/1600W - 6 Minute Full Load - 6 x NEMA 5-15/20R, 1 x NEMA L5-20R | |
| General Information | |
|---|---|
| Manufacturer: | Tripp Lite by Eaton |
| Manufacturer Part Number: | SMART2200SLT |
| Manufacturer Website Address: | https://tripplite.eaton.com/ |
| Brand Name: | Tripp Lite by Eaton |
| Product Line: | SmartPro |
| Product Model: | SMART2200SLT |
| Product Name: | SmartPro SMART2200SLT 2200VA Tower UPS |
| Marketing Information: | 2200VA line-interactive tower UPS system for server, networking and telecommunications equipment. Upright tower form factor. Offers sine wave 120V nominal output in both AC and battery modes. Switches to battery-derived AC output during power failures and extreme voltage variations. Line-interactive automatic voltage regulation (AVR) provides voltage boost/cut during brownouts/overvoltages to maintain regulated 120V nominal output over an input voltage range of 83-145V. Includes NEMA 5-20P input plug and 7 UPS-supported (6 x 5-15/20R & 1 L5-20R) output receptacles. Network-grade AC surge and noise suppression. Network management interfaces support simultaneous communications via USB port, DB9 serial port and slot for Network Management Card option. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all three network interfaces. PowerAlert UPS management software is available via free download. Three-stage metered current monitoring and battery charge status LEDs. Utility power and voltage regulation, and battery warning LEDs. Audible alarm. Self-test. Field-replaceable, hot-swappable internal batteries. Attractive all-black color scheme. |
| Product Type: | Line-interactive UPS | Technical Information |
| Plug/Connector Type: | NEMA 5-20P |
| Receptacle Type: |
|
| Receptacle Detail: |
|
| Emergency Power OFF: | Yes |
| Transfer Time: | 4 ms | Power Description |
| Load Capacity (VA): | 2.20 kVA |
| Load Capacity (Watt): | 1.60 kW |
| Input Voltage: | 120 V AC |
| Input Current: | 14.80 A |
| Output Voltage: | 120 V AC | Management |
| Network Management: | SNMP Manageable | Interfaces/Ports |
| Modem (RJ-11): | Yes |
| USB: | Yes | Battery Information |
| Backup/Run Time (Full Load): | 5 Minute |
| Backup/Run Time (Half Load): | 13 Minute |
| Hot Swappable: | Yes | Physical Characteristics |
| Height: | 10.50" (266.70 mm) |
| Width: | 8.88" (225.43 mm) |
| Depth: | 12.50" (317.50 mm) |
| Form Factor: | Tower |
| Weight (Approximate): | 25.85 kg | Miscellaneous |
| Package Contents: |
|
| Additional Information: |
|
| Certifications & Standards: | Tested to UL1778 (USA), CSA C22.2 No. 107.3 (Canada), RoHS compliant, Class A (Emissions), NOM (Mexico) |
| Software Included: | PowerAlert Software |
| Country of Origin: | China | Warranty |
| Limited Warranty: | 3 Year |
Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.
The manufacturer no longer makes the SMART2200SLT. These UPS are sold today; each card compares one with the discontinued model.
| Spec | SMART2200SLT | Delta |
|---|---|---|
| Capacity | 2200 VA / 1600 W | 2000 VA / 1800 W |
| Topology | Line-Interactive | Online Double-Conversion |
| Form | Tower | Tower/Rack Convertible, 2U |
| Input plug | NEMA 5-20P | NEMA 5-20P |
| Outlets | 6 × NEMA 5-15/20R, 1 × NEMA L5-20R | 8 × NEMA 5-15/20R, 1 × NEMA L5-20R |
| Runtime, half load | 13 min | 11 min |
Differences
| Spec | SMART2200SLT | Xtreme Power |
|---|---|---|
| Capacity | 2200 VA / 1600 W | 2000 VA / 1930 W |
| Topology | Line-Interactive | Online Double-Conversion |
| Form | Tower | Tower |
| Input plug | NEMA 5-20P | NEMA 5-20P |
| Outlets | 6 × NEMA 5-15/20R, 1 × NEMA L5-20R | 1 × NEMA L5-20R, 8 × NEMA 5-20R |
| Runtime, half load | 13 min | 18 min |
Differences
| Spec | SMART2200SLT | Xtreme Power |
|---|---|---|
| Capacity | 2200 VA / 1600 W | 2200 VA / 2000 W |
| Topology | Line-Interactive | Line-Interactive |
| Form | Tower | Tower/Rack Convertible, 2U |
| Input plug | NEMA 5-20P | NEMA 5-20P |
| Outlets | 6 × NEMA 5-15/20R, 1 × NEMA L5-20R | 8 × NEMA 5-15/20R |
| Runtime, half load | 13 min | 12 min |
Differences
Check outlets and the runtime your load needs before ordering. Questions? Call 438-881-3363 or ask for a quote.
The manufacturer no longer makes the SMART2200SLT. These UPS are sold today; each card compares one with the discontinued model.
Questions? Call 438-881-3363 or ask for a quote.
A line-interactive UPS typically needs new batteries every 3 to 5 years. Matching replacement cartridges are listed by UPS model; confirm the exact model before ordering.
Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating (not VA) is the number that matters. Aim for the UPS to run at 60 to 70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list; we'll respond within one business day with sizing guidance.
New units carry the warranty coverage stated by the manufacturer; see the product listing or manufacturer documentation for the applicable terms. Refurbished units are covered by the 1-year UPSPLUSBATTERY warranty handled in Canada.
Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model; contact us if you don't see the right XBP in our catalogue.