Eaton industrial-grade UPS: 9PX 5–22 kVA on 208/230 V, 9SX 8–11 kVA, 93E 20–60 kVA three-phase, 93PM 30–500 kVA modular, and 9395 200 kW–2.25 MW.

Eaton Industrial UPS catalogue

Showing 1-24 of 34

Not sure which one fits? Open the UPS Solutions Builder →

Comparison

Eaton Industrial UPS Systems: Canada

Eaton industrial UPS systems are purpose-built for harsh environments, extended operating temperatures, and three-phase industrial power applications. Deployed in manufacturing, oil and gas, mining, and large-scale facilities where standard UPS systems are insufficient.

Eaton Industrial Applications

  • Manufacturing and process automation
  • Oil and gas remote sites
  • Mining and mineral processing
  • Water treatment and utilities
  • Large three-phase commercial facilities

Our team has deployed Eaton industrial UPS systems in remote and demanding Canadian environments. 📞 438-881-3363 | 📦 Ships across Canada.

Buying several units? Need it configured? For several units or a purchase order, request a written quote. Reply within 1 business day.
Request a quote → 438-881-3363

About Eaton Industrial UPS

Read more: Eaton Industrial UPS

What is an industrial UPS?

Industrial UPS protects loads in environments where power events translate to lost production: SCADA control rooms, programmable logic controllers (PLCs), CNC and motion-control systems, process-industry sensors and actuators, water and wastewater plants, transportation control, and oil-and-gas field equipment. Industrial UPS prioritises isolation-transformer options, wide input voltage tolerance, hard-wired terminal connections, three-phase support, and chassis hardened for harsher ambient conditions.

Eaton's industrial-grade catalog has four tiers: single-phase 9PX 5 to 22 kVA on 208/230 V and 9SX 8 to 11 kVA for control-room and skid-mounted equipment; three-phase 93E 20 to 60 kVA for mid-enterprise (now discontinued; Eaton names the 9355 and 93PM as replacements); 93PM 30 to 500 kVA modular for data-centre and large facility; and 9395 / 9395P 200 kW to 2.25 MW for hyperscale and heavy industrial. UPSPLUSBATTERY.CA stocks the single-phase range and quotes the three-phase 9355, 93PM and 9395 lines on request. For commercial server-room models see Eaton double-conversion online UPS. Full Eaton catalog at Eaton UPS.

Eaton industrial families

FamilyPower rangePhaseConnectionTypical use
9PX (5 to 22 kVA)5 / 6 / 8 / 10 / 11 / 16 / 22 kVASingle, 208/230 VL6-30P or hard-wiredControl panel, light industrial, edge SCADA
9SX (8 to 11 kVA)8 / 11 kVASingle, 208/230 VHard-wiredMid-density industrial single-phase
93E (discontinued)20 / 30 / 40 / 60 kVAThree-phase 208/220 VHard-wiredMid-enterprise data-centre and facility
93PM30 to 500 kVAThree-phaseHard-wired modular cabinetData-centre, hospital, modular hot-swap
9395 / 9395P200 to 2,250 kWThree-phaseHard-wiredHyperscale, large industrial, campus

For most control-room and skid deployments under 22 kVA the answer is 9PX. Above that, 93PM scales to 500 kVA with modular hot-swap and 9395 covers true hyperscale; the 93E, which covered 20 to 60 kVA, is discontinued.

How to choose

Online double-conversion is mandatory

Industrial PLCs, motion drives, and instrumentation generally cannot tolerate the 2 to 4 ms transfer of line-interactive; even brief gaps cause control-loop interruptions. All families above are double-conversion online: zero transfer time and a fully regenerated sine wave at all times. Topology comparison.

Single-phase vs three-phase

Most control-room and skid equipment runs single-phase 208/230 V; 9PX 5 to 22 kVA covers this tier. Eaton's current three-phase options start at 10 kVA with the 9355. Choose three-phase when upstream service is three-phase or when load exceeds ~22 kVA single-phase.

Sizing for industrial inrush

Industrial loads (motor drives, contactors, solenoids) often have inrush currents 6 to 10× nominal. Add nameplate watts × 1.25 buffer for steady-state, then verify the UPS's overload tolerance against expected inrush. 9PX, 93PM, and 9395 tolerate higher transient overload than IT-class UPS. Confirm specific inrush handling with our team.

Battery runtime

Most industrial deployments size battery runtime for graceful shutdown of the controlled process, typically 15 to 30 minutes. 9PX supports EBMs (9PXEBM240RT, 9PXEBM480T) for runtime extension; 93PM and 9395 use external battery cabinets configured at install.

Spec reference

ModelPowerPhaseConnectionReplacement battery
9PX5K5000 VA / 4500 WSingle, 208/230 VL6-30P9PXEBM240RT (EBM)
9PX6K6000 VA / 5400 WSingle, 208/230 VL6-30P or hard-wired9PXEBM240RT (EBM)
9PX8K8000 VA / 7200 WSingle, 208/230 VHard-wired9PXEBM240RT (EBM)
9PX11K11 kVA / 10 kWSingle, 208/230 VHard-wired9PXEBM240RT (EBM)
9PX22K22 kVA / 20 kWSingle, 208/230 VHard-wired9PX EBM
93E 20K (discontinued)20 kVA / 18 kWThree-phase 208/220 VHard-wiredExternal battery cabinet
93PM 100K100 kVAThree-phaseHard-wired modularModular battery cabinet

Replacement batteries

9PX 5 to 22 kVA: 9PXEBM240RT, 9PXEBM480T, and matching 9PXEBM external battery modules. 93E and 93PM: external battery cabinets sized at install. 9395: dedicated battery system. Compatible SLA replacements for 9PX EBM batteries are stocked, matched on voltage, capacity, terminals and connectors. 1-year UPSPLUSBATTERY warranty. Browse Eaton replacement batteries.

Installation and warranty

9PX 5 to 6 kVA on L6-30P plug, dedicated 30 A 208/230 V circuit by licensed electrician per CSA. 9PX 8 kVA+ hard-wired only. 93E, 93PM, and 9395 always require commissioning by qualified Eaton-authorised technician. Warranty (USA and Canada): 9PX 3 years electronics + 2 years battery; 93E and 93PM per service-contract terms; 9395 covered under enterprise service contract. Coordinated through our Canadian team. Shipped from Canada.

FAQ

9PX or three-phase for 20 kVA?

9PX22K is single-phase 208/230 V: fits sites with single-phase distribution. For sites where upstream is already three-phase, look at Eaton's current three-phase lines, the 9355 and 93PM; the 93E 20K is discontinued. Choose by upstream service, not by VA alone.

93PM: when to spec?

When you need modular three-phase 30 to 500 kVA with hot-swappable power and battery blocks for capacity expansion or N+1 redundancy. Always commissioned by Eaton: request a site survey before order.

9395: when to spec?

Hyperscale data centres and large industrial / institutional installations needing 200 kW to 2.25 MW. A capital infrastructure project with site commissioning.

Inrush handling?

9PX and 93PM specify peak overload current and duration. Size the UPS against the worst-case transient.

Battery runtime for graceful PLC shutdown?

15 to 30 minutes is typical. 9PX supports 9PXEBM external packs.

Network management?

Network-M2 card on 9PX, 9SX. SNMP, Modbus TCP, RESTful API: common requirement for SCADA / BMS integration.

Canadian warranty?

Yes: Eaton industrial family factory warranty covers USA and Canada. Coordinated through our Canadian team.