Eaton 5S700LCD 700 VA / 420 W Line-Interactive UPS
- Power
- 700 VA / 420 W
- Form
- Tower
- Outlets
- 8× NEMA 5-15R
Eaton line-interactive UPS: 5E (650 VA to 2200 VA), 5P (650 VA to 3000 VA), 5PX / 5PX G2 (1000 VA to 3000 VA, high PF).
Not sure which one fits? Open the UPS Solutions Builder →
This series refurbished, from $319.99: load-tested, new batteries, 1-year warranty.
Eaton line interactive UPS systems provide reliable power protection with automatic voltage regulation for server rooms, network closets, and professional workstations. Intelligent Buck-Boost AVR technology corrects voltage without battery engagement, maximizing battery life and ensuring stable power output.
📦 Ships across Canada | 📞 438-881-3363
Line-interactive UPS keeps the load on utility power most of the time and uses an autotransformer with Automatic Voltage Regulation (AVR) to correct sustained low or high voltage without engaging the battery. On a true outage, transfer to battery takes a few milliseconds, fast enough for most modern server, networking and storage power supplies. It suits most SMB server, networking and POS loads.
Eaton's line-interactive catalog covers three families: 5E for entry-tier business, 5P for the rack workhorse, and 5PX / 5PX G2 for high-PF and extended-runtime deployments. UPSPLUSBATTERY.CA offers the line with matching Eaton replacement batteries. For loads that can't tolerate transfer time, see Eaton double-conversion online UPS (9PX / 9SX). For entry standby tier, see Eaton standby UPS. Full Eaton catalog: Eaton UPS.
| Family | VA range | Form factor | PF | Notable features |
|---|---|---|---|---|
| 5E | 650 VA to 2200 VA | Tower | 0.6 | Entry business, USB, basic AVR |
| 5P | 650 VA to 3000 VA | Tower or 1U / 2U rack | 0.77 | Pure sine, LCD, USB / serial, optional Network-M2 |
| 5PX / 5PX G2 | 1000 VA to 3000 VA | 2U rack/tower | 0.9 to 1.0 | High PF, extended-runtime via EBMs, IPM, optional NMC |
5P covers most rack deployments. 5PX adds higher PF and external battery support for extended runtime. 5E is the entry-tier tower for budget-constrained workstation and small-office deployments.
5P runs about 0.77 PF: 5P1000R 1000 VA / 770 W, 5P1500R 1440 VA / 1100 W. 5PX runs 0.9 to 1.0 PF: 5PX1500IRT 1500 VA / 1350 W, 5PX1500RT 1440 VA / 1440 W, with EBM support (up to 4 EBMs). Choose 5P when stock runtime is sufficient. Choose 5PX when extended runtime via EBMs is needed or when high PF is the binding spec.
Add nameplate watts of all loads, multiply by 1.25 buffer, pick UPS whose watt rating exceeds. Two 1U servers (~250 W each) + 24-port switch (~60 W) + NAS (~100 W) ≈ 660 W × 1.25 = 825 W → 5P1500R (1100 W) fits. UPS sizing guide.
Move to 9SX or 9PX online when the load can't tolerate any transfer (medical, VoIP, precision lab, industrial control), or when utility frequency drift exceeds line-interactive AVR correction range. Topology comparison.
| Model | Power | Form factor | Outlets | Replacement battery |
|---|---|---|---|---|
| 5E1500i | 1500 VA / 900 W | Tower | (8) IEC C13 | Check the unit label |
| 5P1500R | 1440 VA / 1100 W | 1U rack | (5) 5-15R | Check the unit label |
| 5P2200 | 1950 VA / 1920 W | Tower | (8) 5-20R | Check the unit label |
| 5P3000IRT | 3000 VA / 2700 W | 2U rack/tower | (8) C13, (1) C19 | Check the unit label |
| 5PX1500RT | 1440 VA / 1440 W | 2U rack/tower | (8) 5-15R | Check the unit label |
| 5PX3000RT | 3000 VA / 2700 W | 2U rack/tower | (8) C13, (1) C19 | Check the unit label |
5P, 5PX ship with Eaton IPM software. Network-M2 card slot for SNMP / Modbus / web monitoring on 5P and 5PX (optional add-on; standard on G2 NC variants).
5P / 5PX use 744-A battery part numbers; check the unit label for yours (eaton.com lists EBP-1613 for the 5PX1500RTG2). The 5PX takes up to 4 EBMs (for example 5PXEBM48RTG2); the 5P has no EBM option (eaton.com: 'See Eaton 5PX UPS for extended runtimes'). We stock compatible replacements matched on voltage, capacity, terminals and connectors. 1-year UPSPLUSBATTERY warranty. See Eaton replacement batteries.
Up to 1500 VA: NEMA 5-15P or IEC C14 plug-and-play. 2200 / 3000 VA: typically L5-30P or IEC C20 (-i suffix). Warranty: 3 years on electronics and 3 years on batteries with registration on 5P and 5PX (eaton.com). Coordinated through our Canadian team. Shipped from Canada.
Same line-interactive topology. 5P at about 0.77 PF, broad VA range, no EBM option. 5PX at 0.9 to 1.0 PF, supports up to 4 EBMs for extended runtime. For straightforward rack deployments where stock runtime is sufficient, 5P. For high-density loads or extended ride-through, 5PX.
Yes on 5P and 5PX: pure sine on battery. 5E is simulated sine on lower SKUs. For any active-PFC server PSU, sensitive AV, or lab equipment, choose 5P, 5PX, or step up to online 9SX / 9PX.
Network-M2 card slot on 5P and 5PX. Provides SNMP v1/v2c/v3, Modbus TCP, web management, RESTful API, integration with Eaton IPM software for fleet monitoring and graceful shutdown.
Yes. The 5PX takes up to 4 EBMs (eaton.com). Eaton's runtime charts give the minutes per EBM.
eaton.com lists the 5P and 5PX batteries as user replaceable; check the user manual before swapping them under load.
Sealed lead-acid batteries typically last 4 to 5 years at 20 to 25 °C, climate-controlled. When to replace UPS battery.
Yes: Eaton 5P and 5PX factory warranty terms cover USA and Canada. RMA coordinated through our Canadian team. Shipped from Canada.