XPC 1–3 kVA UPS — Canada

Xtreme Power Mid-Range UPS (1–3kVA)

Xtreme Power Conversion 1–3 kVA UPS — S71 line-interactive, P80 / P80g sinewave, T91 / T91i online tower, P91 / P91g online rack/tower, P91 Li / P91g Li lithium online, J90 / J90i lithium 1U. The mid-range tier covering server rooms, network closets, lab benches, and edge compute.

  • Ships from Canada
  • Canadian shipping
  • Manufacturer warranty

Xtreme Power Mid-Range UPS (1–3kVA) catalogue

Showing 1-24 of 33
Buying several units? Need it configured? Volume pricing and a written quote within 1 business day — purchase orders / Net-30 welcome.
Request a quote → 438-881-3363

About Xtreme Power Mid-Range UPS (1–3kVA)

What is a 1–3 kVA UPS?

1–3 kVA is the workhorse range for commercial IT — single-phase 120 V (or 208/230 V on the high end), tower or 1U/2U rack/tower. One UPS feeds a small server stack, a network closet, a branch IT cabinet, a lab bench instrument cluster, or an edge compute node. XPC competes hard in this segment with line-interactive (S71, P80, P80g), online (T91 / T91i, P91 / P91g), online lithium (P91 Li / P91g Li, J90 / J90i), and 5–10 kVA for the upper-density slice.

UPSPLUSBATTERY.CA stocks the full XPC mid-range across all topologies. For under-1 kVA workstation tier see XPC small UPS. For above 3 kVA see XPC high-power 3–10 kVA. For full XPC catalog see Xtreme Power Conversion.

XPC 1–3 kVA models by topology

TopologySeries1 – 1.5 kVA2 – 2.2 kVA3 kVA
Line-interactive TowerS71 (120 V)S71-1000 / 1500
Line-interactive SinewaveP80 (120 V) / P80g (230 V)P80-1100 / 1500P80-2000 / 2200P80-3000 / P80g-3000
Online TowerT91 / T91iT91-1000 / 1500T91-2000 / T91i-2000T91-3000 / T91i-3000
Online Rack/Tower SLAP91 / P91gP91c-1000, P91-1000 / 1500, P91g-1500P91-2000 / P91g-2000P91-3000 / P91g-3000
Online Rack/Tower LithiumP91 Li / P91g LiP91-1.5KLi / P91g-1.5KLiP91-2KLi / P91g-2KLiP91-3KLi / P91g-3KLi
Online 1U LithiumJ90 / J90iJ90-1KLi / 1.5KLi (and J90i)J90-2KLi / J90i-2KLiJ90-3KLi / J90i-3KLi

Watt ratings vary by topology and power factor. P91-1500 SLA: 1500 VA / 1450 W. P91g-1500 SLA: 1500 VA / 1500 W (Unity PF). P91-1.5KLi: 1500 VA / 1350 W. P91g-1.5KLi: 1500 VA / 1500 W. T91-2000: 2000 VA / 1930 W. P91-3000: 3000 VA / 2880 W. P91g-3000: 3000 VA / 3000 W (Unity PF).

How to choose

Topology decision

Server room with reasonably clean utility — S71 or P80 line-interactive (P80 adds pure sine + SNMP slot). Lab, medical, or industrial gear that can't tolerate transfer time — T91, P91, or P91g online. Long-deployment site, hot ambient, or hard-to-reach rack — P91 Li or J90 lithium (15-year rated battery, 50 °C operating). 1U rack budget — J90 or P91c. Read line-interactive vs online UPS.

SLA vs Lithium at this tier

SLA: lower upfront, ~3-year battery service life. Lithium: higher upfront, 15-year rated by XPC, 50 °C operating range. Lithium pays back over 5+ year deployments and in hot ambient. P91 Li / P91g Li / J90 / J90i carry 6-year warranty (USA and Canada) vs 3-year on SLA P91 / P91g. XPC lithium UPS.

Form factor

Tower-only: T91 / T91i, S71. 1U rack/wall: J90 / J90i, P91c. 2U rack/tower: P91, P91g, P91 Li, P91g Li, P80 sinewave above 1100 VA.

Plug type and circuit

Up to 1500 VA: NEMA 5-15P (15 A wall outlet). 2000–2200 VA: NEMA 5-20P or L5-20P. 3000 VA at 120 V: NEMA L5-30P (locking 30 A). 230 V variants (T91i, P91g, P91g Li, J90i): IEC C14 or C20 inlet. XPC 208/230 V UPS.

Sizing

Add nameplate watts of all loads, multiply by 1.25 buffer, pick UPS whose watt rating exceeds. Two 1U servers (~250 W each) + 24-port switch (~60 W) + NAS (~100 W) ≈ 660 W → P91-1000 SLA / 1000 W marginal — step to P91-1500 / 1450 W. Sizing guide.

Replacement batteries and EBPs

P91 / P91g support P91-BP36 (1500 VA), P91-BP36E, P91-BP48 (2000 VA), P91-BP72 (3000 VA) external battery packs. T91 supports T91-BP36A (1000–1500), T91-BP72A (2000–3000) — up to 7 BP per UPS. P80 1500/2000 use P90-BP48; P80 2200/3000 / P80g-3000 use P90-BP72. J90-2K / 3K Li accept J90-EBP48 lithium. SLA cartridges in stock as compatible aftermarket — 1-year UPSPLUSBATTERY warranty. Lithium packs factory XPC only. Browse XPC UPS replacement batteries and XPC battery packs.

Installation and warranty

1500/2000 VA plug-and-play on 5-15P / 5-20P. 3000 VA L5-30P needs a dedicated 30 A 120 V circuit by licensed electrician per CSA, OR run 230 V via P91g / J90i with C20 inlet on a dedicated 208/230 V circuit. Warranty (USA and Canada): T91 / P91 / P91g / S71 / P80 standard 3-year, optional 5-year (P915SP15, P915SP23, T915SP715, T915SP23, S715SP57, S715SP152). P91 Li / P91g Li / J90 / J90i 6-year (2-year above 40 °C ambient). Coordinated through our Canadian team. Shipped from our Canadian warehouse — see shipping policy for rates and timing. Replies within 1 business day.

FAQ

What's the most popular 1–3 kVA XPC?

P91-1500 and P91-3000 — online double-conversion fits the broadest set of IT, lab, and edge-compute requirements. S71-1500 dominates straightforward office deployments where line-interactive is enough.

Why size on watts not VA?

Modern loads draw close to unity PF. The watt number is what your load actually pulls — VA can include reactive component. Read UPS sizing guide.

Pure sine wave?

Yes on P80 / P80g, T91 / T91i, P91 / P91g, P91 Li / P91g Li, J90 / J90i. S71 produces simulated sine on battery. For any active-PFC server PSU, sensitive AV, or lab equipment, use a sinewave or online model.

Hot-swap batteries?

Most XPC mid-range support cartridge or pack swap. Confirm by model — some require brief load transfer to bypass.

Network management?

SNMP-2PV3 internal card on P80, P91, P91g, P91 Li, P91g Li, T91, J90. MODBUS-IN card for industrial / BMS. RELAY-MINI for dry-contact. SNMP-EMPV2 environmental sensor.

Battery life?

SLA: 4–5 years climate-controlled. Lithium (P91 Li / P91g Li / J90 / J90i): up to 15 years rated, 50 °C operating. When to replace UPS battery.

Canadian warranty?

Yes — every XPC mid-range series carries factory warranty terms explicitly covering USA and Canada. RMA does not require cross-border shipping. Shipped from our Canadian warehouse.

1–3kVA UPS systems — the sweet spot for small server racks, network closets, edge compute, and pro workstations.

The 1–3kVA range covers most small-to-medium business needs: a half-loaded 1U or 2U rack of servers and switches, a video editing workstation, an edge compute node, or a CCTV/access-control panel for a small facility. Online double-conversion is recommended in this range whenever loads include VoIP, medical, or industrial control gear.

What's in this collection

Xtreme Power's 1–3kVA range covers the S71-1000/1500 (line-interactive), P80/P80g 1500–3000 (line-interactive), P91/P91g/T91 1000–3000 (online), and the J90 / P91 Li / P91g Li lithium series — at 120V and 208/230V.

Why buy from UPSPLUSBATTERY.CA
Specifying an XPC 1–3 kVA?

Canadian XPC mid-range UPS from stock.

Our Canadian team has specified APC, Eaton, Tripp Lite, Vertiv, Mitsubishi, Toshiba, CyberPower, XPC, and Delta UPS for healthcare, data centres, and government. Enquiries answered in business hours.