APC Galaxy VS 20 kW Three-Phase UPS — Galaxy VS Series Hub (10–100 kVA)
- VA
- 20000
- Watts
- 20000
- Form
- Tower
- Topology
- Online Double-Conversion
APC industrial-grade UPS — Smart-UPS SRT 5–10 kVA on 208/230 V, Easy UPS On-Line SRV 6–20 kVA, Symmetra LX modular, and Galaxy V series three-phase 10 kVA to 1.5 MW. For SCADA, PLC, control rooms, and process-industry power.
Industrial UPS protects loads in environments where power events translate to lost production — SCADA control rooms, programmable logic controllers (PLCs), CNC and motion-control systems, process-industry sensors and actuators, water and wastewater plants, transportation control, and oil-and-gas field equipment. Compared to IT-rack UPS, industrial UPS prioritises galvanic isolation, wide input voltage tolerance, hard-wired terminal connections, three-phase support, and chassis hardened for harsher ambient conditions.
APC's industrial-grade catalog has three tiers: single-phase Smart-UPS SRT 5–10 kVA and Easy UPS On-Line SRV 6–20 kVA for control-room and skid-mounted equipment; modular Symmetra LX for scalable rack-deployable redundancy; and three-phase Galaxy V series 10 kVA to 1.5 MW for facility-scale and process plants. UPSPLUSBATTERY.CA stocks the single-phase range and quotes the three-phase Galaxy line on request. For commercial server-room equivalents see APC double-conversion online UPS. Full APC catalog at APC UPS.
| Family | Power range | Phase | Connection | Typical use |
|---|---|---|---|---|
| Smart-UPS SRT (5–10 kVA) | 5 / 6 / 8 / 10 kVA | Single, 208–230 V | L6-30P or hard-wired | Control panel, light industrial, edge SCADA |
| Easy UPS On-Line SRV | 6 / 10 / 15 / 20 kVA | Single, 230 V | Hard-wired terminal | Cost-competitive on-line, tower deployment |
| Symmetra LX | 4 – 16 kVA scalable | Single, 208/230 V | Hard-wired | Modular N+1 industrial control redundancy |
| Galaxy VS / VL / VM | 10 – 1500 kVA | Three-phase | Hard-wired | Facility-scale, integrated transformers and bypass |
For most control-room and skid deployments under 10 kVA the answer is SRT or Easy UPS On-Line. Above 20 kVA single-phase or where three-phase is the upstream service, Symmetra and Galaxy are the right tier.
Industrial PLCs, motion drives, and instrumentation generally cannot tolerate the 2–4 ms transfer of line-interactive — even brief gaps cause control-loop interruptions. All four families above are double-conversion online: zero transfer time, full input isolation, fully regenerated sine wave at all times. Topology comparison.
Most control-room and skid equipment runs single-phase 208/230 V. Three-phase is required when upstream service is three-phase or when load exceeds ~20 kVA. Galaxy V series covers the three-phase tier from 10 kVA up to 1.5 MW with integrated transformer options for industrial step-down or step-up.
Industrial loads (motor drives, contactors, solenoids) often have inrush currents 6–10× nominal. Add nameplate watts × 1.25 buffer for steady-state, then verify the UPS's overload tolerance against expected inrush. SRT and Galaxy tolerate higher transient overload than IT-class UPS. Read UPS sizing guide and confirm specific inrush handling with our team.
Most industrial deployments size battery runtime for graceful shutdown of the controlled process — typically 15–30 minutes. SRT and Galaxy support external battery cabinets to extend ride-through significantly. Easy UPS On-Line SRV ships with extended-runtime battery options at order.
| Model | Power | Phase | Connection | Replacement battery |
|---|---|---|---|---|
| SRT5KRMXLT | 5000 VA / 4500 W | Single, 208 V | L6-30P, 6 ft | APCRBC140 |
| SRT6KXLT / SRT6KRMXLT | 6000 VA / 6000 W (unity PF) | Single, 208 V | L6-30P or hard-wired | APCRBC140 |
| SRT8KXLT | 8000 VA / 8000 W (unity PF) | Single, 208 V | Hard-wired | APCRBC140 (×2) |
| SRT10KXLT | 10 kVA / 10 kW (unity PF) | Single, 208 V | Hard-wired | APCRBC140 (×2) |
| SRV6KIL | 6 kVA / 6 kW | Single, 230 V | Hard-wired terminal | SRV192BP-9A or factory string |
| SRV10KIL | 10 kVA / 10 kW | Single, 230 V | Hard-wired terminal | SRV192BP-9A or factory string |
| SYA8K16RMI Symmetra LX | 8 kVA scalable to 16 | Single, 208/230 V | Hard-wired | SYBT2 / SYBT5 module |
SRT 5–10 kVA: APCRBC140 (192 V, 5 Ah × 32 cells, 1–2 cartridges per UPS). Easy UPS On-Line SRV: SRV192BP-9A external battery pack and factory strings. Symmetra LX: SYBT2 and SYBT5 hot-swap battery modules. Galaxy: dedicated battery cabinet (string sized at install). We stock genuine APC and compatible aftermarket SLA cartridges for the SRT series — same V, Ah, terminal, connector spec as factory. 1-year UPSPLUSBATTERY warranty on aftermarket. Browse APC Smart-UPS RT replacement batteries.
SRT 5 kVA on L6-30P; 6 / 8 / 10 kVA hard-wired by licensed electrician per CSA. Easy UPS On-Line SRV always hard-wired by licensed electrician. Symmetra LX and Galaxy require commissioning by qualified Schneider-authorised technician — site survey recommended. Warranty (USA and Canada): SRT 3 years electronics + 2 years battery; SRV 2–3 years electronics + 1–2 years battery; Symmetra and Galaxy per service-contract terms. Coordinated through our Canadian team. Shipped from our Canadian warehouse — see shipping policy for rates and timing. Replies within 1 business day.
Both online double-conversion. SRT is the established APC Smart-UPS SRT line — full PowerChute integration, AP9641 NMC standard on 5 kVA+, broader receptacle options. Easy UPS On-Line SRV is the cost-competitive on-line tier — fewer accessory options, hard-wired terminal, 230 V single-phase only. For SCADA / control-room with deep PowerChute integration, choose SRT. For straightforward on-line conditioning, SRV is typically lower-cost.
When upstream service is three-phase, when load exceeds ~20 kVA single-phase, or when integrated transformer step-down / step-up is required. Galaxy VS covers 10–150 kVA, Galaxy VL 200–500 kVA, Galaxy VX up to 1.5 MW. Always commissioned by Schneider — request a site survey before order.
SRT and Galaxy specify peak overload current and duration in their spec sheets. For motor-start inrush and solenoid pull-in, size the UPS against the worst-case transient — not just the steady-state nameplate. Our team can review your load profile and recommend the right SKU — replies within 1 business day.
15–30 minutes is typical. SRT supports SRT72BP / SRT96BP external battery packs. SRV and Symmetra accept extended-runtime battery cabinets sized at order. Galaxy battery cabinets sized to ride-through requirement at install.
AP9641 Network Management Card 3 standard on SRT 5 kVA and above; SmartSlot option on smaller SRT and on SRV. Provides SNMP v1/v2c/v3, web management, Modbus TCP — common requirement for SCADA / BMS integration.
Standard SRT and SRV electronics rated to 40 °C ambient. Battery service life halves roughly every 8 °C above 25 °C — for hot industrial closets, plan battery replacement cycles tighter or specify Smart-UPS Ultra (SRTL) lithium-ion which tolerates higher ambient with less degradation.
Yes — APC Smart-UPS SRT, Easy UPS On-Line SRV, Symmetra, and Galaxy factory warranty terms cover USA and Canada. Coordinated through our Canadian team. Shipped from our Canadian warehouse.
APC industrial UPS systems are engineered for demanding environments including manufacturing facilities, mining operations, outdoor installations, and harsh industrial settings. Designed to withstand extended temperature ranges, vibration, and dust exposure where standard UPS systems cannot operate reliably.
Our team has hands-on experience deploying APC industrial UPS systems in demanding Canadian environments — including Arctic mining operations and remote facilities. 📞 438-881-3363 | 📦 Ships across Canada.
Our Canadian team has specified APC, Eaton, Tripp Lite, Vertiv, Mitsubishi, Toshiba, CyberPower, XPC, and Delta UPS for healthcare, data centres, and government. Enquiries answered in business hours.