Skip to product information
1 of 1

APC

APC MGE Galaxy 3500 30 kVA Three-Phase UPS — Galaxy 3500 Series Hub

APC MGE Galaxy 3500 30 kVA Three-Phase UPS — Galaxy 3500 Series Hub

Quote on request
Request a quote →

Items above $10000 are handled by quote so we can confirm availability, freight, and final pricing.

Written reply within 1 business day — no obligation.

Supports extended runtime — add battery packs in your quote

  • Ships from our Canadian warehouse — CAD pricing, no customs
  • New in box — manufacturer warranty applies
  • Purchase orders / Net-30 welcome (B2B & public sector)

Questions? 438-881-3363 · Mon–Fri

View full details
Product details

About this UPS

APC / Schneider Electric MGE Galaxy 3500 three-phase UPS — series hub. The MGE Galaxy 3500 is APC's rugged three-phase tower UPS for industrial and facility loads — double-conversion online with integrated battery modules, sized 10 to 30 kVA. Its runtime is set by the battery configuration you choose (the F2/F3/F4 in the reference): we stock nine configurations and publish their measured runtimes below. Turnkey supply: equipment, freight, licensed installation, batteries and commissioning in one quote — request yours, call 438-881-3363, or compare families in the three-phase UPS guide.

✓ Full turnkey projects — we do the hard work✓ PO / Net-30 for business & public sectorTrade-in credit on replaced units

APC MGE Galaxy 3500 family — stocked models

Range: 10–30 kVA · tower · 208/220 V class. Double-conversion online, three-phase.

Model Link
Galaxy 3500 10 kVA — F3 battery config View / quote →
Galaxy 3500 10 kVA — F4 battery config View / quote →
Galaxy 3500 15 kVA — F2 battery config View / quote →
Galaxy 3500 15 kVA — F4 battery config View / quote →
Galaxy 3500 20 kVA — F2 battery config View / quote →
Galaxy 3500 20 kVA — F3 battery config View / quote →
Galaxy 3500 20 kVA — F4 battery config View / quote →
Galaxy 3500 30 kVA — F3 battery config (this page) View / quote →
Galaxy 3500 30 kVA — F4 battery config View / quote →

All nine stocked configurations are linked above. The runtime table below uses APC's published figures for each configuration — pick by the hold time you actually need. Send the requirement →

Where the MGE Galaxy 3500 fits

Industrial plantsWater treatmentBuilding servicesLegacy replacements

How the MGE Galaxy 3500 compares

The rugged industrial classic: a massive installed base and per-configuration published runtimes; for new builds the Galaxy VS is its modern successor — we quote both when the choice is open. Undecided between families? Start from the three-phase UPS family guide.

Runtime & expansion — batteries, cabinets, bypass

Unusually for this class, the Galaxy 3500's runtime is baked into the model you buy — more internal battery modules (F2 → F3 → F4) mean longer holds. Published runtimes per stocked configuration:

Configuration Half load Full load
10 kVA F3 1 h 34 min 38.8 min View →
10 kVA F4 2 h 13 min 56.3 min View →
15 kVA F4 1 h 09 min 27.7 min View →
20 kVA F2 22.2 min 7.1 min View →
20 kVA F3 33.2 min 11.9 min View →
20 kVA F4 48.5 min 18.8 min View →
30 kVA F3 19.1 min 5.7 min View →
30 kVA F4 28.3 min 9.8 min View →

Runtimes are the manufacturer's published figures for new batteries at nominal conditions.

Turnkey: from quote to running system

  1. Tell us the requirement — model or just load, runtime and site details.
  2. One configured quote — UPS, batteries/cabinets, bypass, freight, installation and commissioning together.
  3. We do the hard work — logistics, rigging, licensed electricians, startup, and preventive maintenance afterward. Replacing equipment? We buy back working units.

Common questions

How much runtime does an MGE Galaxy 3500 give?

It depends on the battery configuration in the reference: at 20 kVA, the F2 config holds about 7 minutes at full load, the F4 about 19 minutes — and roughly triple those figures at half load. The table above lists APC's published numbers per stocked model.

Is the Galaxy 3500 still a sound purchase?

It has a huge industrial installed base, batteries and service remain available, and for like-for-like replacement it avoids re-engineering the electrical room. For new builds we'll also quote its modern successor so you can compare.

Which battery configuration should I choose?

Start from the hold time your process needs: enough to ride through short outages, or enough to bridge a generator start with margin. We match the F-configuration to that number instead of overselling battery.

Do you install and commission it?

Yes — turnkey: freight, positioning, licensed electrical connection, startup and load testing in one quote. We do the hard work.

How do pricing and lead time work on three-phase systems?

Three-phase systems are quoted, not carted: pricing depends on configuration, batteries, freight class and installation scope. Send the requirement and you get a firm, itemized quote — and honest availability for each option before you commit.

Do you supply and install outside major cities?

Yes — supply, freight and installation are coordinated wherever the site is, through our network of licensed electricians and riggers. Remote and industrial sites are quoted with site logistics included.

All product and company names are trademarks of their respective holders. UPS Plus Battery is an independent supplier and is not affiliated with, endorsed by, or sponsored by the manufacturers listed.

Related

Get the configured quote

Model, batteries, bypass, freight, installation — one number, one accountable team.

Request a quote →or call 438-881-3363
Specifications

Technical specifications

Power
VA Rating
30000VA
Wattage
24000W
Topology
Online Double-Conversion
Waveform
Pure Sine Wave
Input
Input Voltage
208V
Output
Output Voltage
120V
Features
Form Factor
Tower
Connectivity
["RS-232 Serial""SNMP (via Network Management Card)""HTTP/Web Management"]
Extended Runtime Capable
true
Condition
New
Dimensions
1491 × 523 × 838 mm (58.70 × 20.60 × 33.00 in)
Weight
535.69kg
Manufacturer Warranty
1 year
Backup runtime

How long it'll keep your equipment up.

Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.

Half load (12000 W) 19.0 min
Full load (24000 W) 5.7 min

Need more runtime? This UPS accepts external battery packs (XBPs). Contact us about XBP options →

W
Estimated runtime min

Estimate based on manufacturer-specified runtime curve. Real-world runtime varies with battery age, ambient temperature, and load profile.

Shipped across Canada
Shipped from our Canadian warehouse. See shipping policy for rates and timing.
Manufacturer-backed
New UPS units carry the full manufacturer warranty registered to you on receipt.
14 years in business
UPSPLUSBATTERY has supplied Canadian UPS systems since 2012.
Sizing & install help
Email your load profile — we'll spec the right UPS within one business hour.
Frequently asked

Before you order

How do I know this UPS will run my equipment?

Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating — not VA — is the number that matters. Aim for the UPS to run at 60–70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list and we'll size the right UPS within one business hour.

What's covered by the warranty, and how long does it last?

New units carry the full manufacturer warranty registered to you on receipt. The manufacturer handles claims directly via their North American support channel. Refurbished units are covered by our own 1-year UPSPLUSBATTERY warranty handled in-house in Canada.

Can I extend runtime beyond what's shown above?

Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model — contact us if you don't see the right XBP in our catalogue.