Rail and mounting kits: putting the UPS where the room needs it

Not every UPS ends up in a rack. Some slide into four-post rails, some hang on two-post telco frames, some bolt to a wall, and the heavy ones anchor to the floor for seismic zones. This collection holds the Xtreme Power Conversion mounting hardware for their UPS families, plus the enclosures and anchor kits the modular systems need.

The line covers 4-post and 2-post rail kits, shelf kits, wall-mount brackets, DIN rail mounts, seismic anchor kits and modular enclosures for the M90S and M90C families.

Kits at a glance

A representative selection. The full list is in the product grid below.

PartTypeFits
P90-RAIL4-post rail kitP80 800 VA to 5 kVA, P90 1 to 3 kVA
P90L-RAIL4-post rail kitP91, P90L 5K, 6K, 10K
XPC-2PRAIL2-post rail kitP80, P90, P90L, NXRT 800 VA to 5 kVA
XPC-2POST2-post shelf kitP91, P90L 5K, 6K, 10K
PV-WMBWall-mount bracketP80, P90, P90L series
T90-WMBWall-mount bracketT91 700 to 1500 VA
J60-DINDIN rail mountJ60
M90S-RMKRack-mount kitM90S-4S, M90S-6S, M90C-6S, M90Ci-6S
M90S-RAIL2SRail kitM90S-ENC2 2-slot enclosure
M90-SEISSeismic anchor kitM90-ENC
X90-SEISSeismic anchor kitX90-2S
M90C-ENC66-slot enclosureM90C modular system

Match the kit to the exact UPS model and chassis depth; rails are family-specific.

How to choose

Start with the frame you have. Four-post server racks take 4-post rails; two-post telco frames take 2-post rails or shelves. The kits are not interchangeable, and the wrong one turns into a drill project.

Check depth before weight. A rail kit holds a given chassis at a given depth range. Measure the rack's usable depth against the UPS, then trust the kit's rating rather than improvising brackets.

Wall mounts are for the small units. The brackets in this line fit the compact families, the P80 to P90L series and the T91 700 to 1500 VA. Large UPS units belong on the floor or in the rack, not on drywall.

Seismic zones need anchors. In parts of Canada the building code requires anchored equipment. The SEIS kits bolt specific XPC frames to the slab, sized per enclosure.

Mind the weight. A rail or bracket kit carries a specific chassis, and a UPS with internal batteries weighs more than it looks. Check the kit against the model, not against a similar-looking neighbour, and never mix manufacturers' parts on one installation.

Modular systems need their enclosures. The M90S and M90C modular frames live in slot enclosures, and the rack-mount kits put those enclosures in standard racks. Plan the slots, then the rails.

Why buy mounts here

  • Factory kits matched to every XPC UPS family
  • 2-post, 4-post, wall, DIN and seismic options in one collection
  • Enclosures for the modular M90S and M90C systems
  • Ships from Canada.

Quotes, configuration and shipping

Tell us the UPS model and the rack or wall it is going into, and we confirm the kit. Request a quote for multi-unit installations. Ships from Canada.

Related: XPC UPS accessories and UPS accessories.

Frequently asked questions

Will a 2-post rail kit fit a 4-post rack?
No. Use the 4-post kit for server racks; the 2-post rails and shelves are for telco-style frames.

What depth rack do the rails need?
Each kit states its chassis and depth range. Check both against your rack before ordering; send us the model if it is close.

Can I wall-mount any UPS?
Only the compact families listed here have brackets. Floor-standing and modular systems stay off walls.

What does a seismic kit do?
It anchors the enclosure to the building structure so an earthquake cannot walk it off its position. The kits are matched to specific XPC frames.

Do the enclosures include rails?
Slot enclosures and rail kits are separate parts; the M90S-RAIL2S pairs with the M90S-ENC2 enclosure, for example.

Do the kits include screws?
The factory kits ship with the fasteners their design calls for. If your rack has threaded holes or you are mounting into a telco frame, confirm the hardware matches before installation day.

Can I move a kit between UPS models?
Only within the family the kit lists. A rail kit that carried a P80 will not carry a P91 chassis; the mounting points and weight differ.

Rack rails, wall-mount brackets, shelf kits, DIN-rail mounts, seismic anchors and mounting hardware for installing UPS systems and battery cabinets in racks, towers or wall locations.

Why buy from UPSPLUSBATTERY.CA
Still narrowing down

Talk to a Canadian UPS specialist.

Our Canadian team has specified APC, Eaton, Tripp Lite, Vertiv, Mitsubishi, Toshiba, CyberPower, XPC, and Delta UPS for healthcare, data centres, and government. Enquiries answered in business hours.