About this UPS
- Brand: APC by Schneider Electric
- Product Type: Line-interactive UPS
- Manufacturer Part Number: BR700G
- Input Voltage: 120 V
- Form Factor: Tower
- Product Family: Back-UPS RS
- Backup/Run Time (Half Load): 12 Minute
- Backup/Run Time (Full Load): 3 Minute
- Load Capacity: 700 VA/450 W
Marketing Information: This product is part of the Back-UPS Pro range. This 700VA UPS has 6 total outlets, 3 outlets provide UPS power backup and surge protection, 3 outlets offer surge protection only. It features a built-in AVR and a LCD interface with audible alarms. Its dimensions are 7.48 x 3.58 x 12.2 inches and 15.76 lbs. The Back-UPS Pro family offers guaranteed power protection for high-performance computer systems, routers, external storage devices, game consoles, and other home and business electronics.
| PRODUCT SPECIFICATIONS | |
|---|---|
| Plug/Connector Type | NEMA 5-15P |
| Receptacle Type | NEMA 5-15R |
| Receptacle Detail |
|
| Number of Battery & Surge Outlets | 6 |
| Cord Length | 6 ft (1.83 m) |
| Load Capacity (VA) | 700 VA |
| Load Capacity (Watt) | 450 W |
| Input Voltage | 120 V |
| Output Voltage | 120 V AC |
| Waveform Type | Stepped Approximated Sine Wave |
| Surge Energy Rating | 354 J |
| Serial Port | Yes |
| USB | Yes |
| Battery Chemistry | Lead Acid |
| Backup/Run Time (Full Load) | 3 Minute |
| Backup/Run Time (Half Load) | 12 Minute |
| Typical Battery Recharge Time | 12 Hour |
| Hot Swappable | Yes |
| Color Family | Black |
| Product Color | Black |
| Height | 7.48" (190 mm) |
| Width | 3.58" (91 mm) |
| Depth | 12.20" (310 mm) |
| Form Factor | Tower |
| Weight (Approximate) | 15.76 lb (7148.62 g) |
| Package Contents |
|
| Certifications & Standards | NOM|T�V|ENERGY STAR V2.0 (USA) |
| Energy Star | Yes |
| Green Premium | Yes |
| Optimized Energy Efficiency | Yes |
| Product Take Back Program | Yes |
| Mercury Free | Yes |
| RoHS Exemption Information | https://download.schneider-electric.com/files?p_enDocType=Declaration+of+Conformity+%28Sustainability%29&p_Doc_Ref=BR700G_ROHS_DECLARATION&p_FileName=BR700GKIT_ROHS_DECLARATION_US.pdf |
| REACH Declaration URL | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=exportPdfReach&pid=61763610&lang=en-us |
| EU RoHS Declaration URL | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=61763610&lang=en-us |
| Environmental Profile Availability | https://download.schneider-electric.com/files?p_enDocType=Environmental+Disclosure&p_Doc_Ref=ENVPEP1712010_EN |
| End of Life Manual Availability | https://download.schneider-electric.com/files?p_enDocType=Circularity+Profile&p_Doc_Ref=ENVEOLI1712010_EN |
| California Proposition 65 Warning | "WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov" |
| Energy Star URL | https://www.energystar.gov/products/uninterruptible_power_supplies |
| REACH free of SVHC | No |
| Toxic Heavy Metal Free | Yes |
| WEEE Statement | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
| Limited Warranty | 3 Year |
| Additional Warranty Information | 3 years repair or replace |
| Directly Connected Equipment Guarantee |
|
Technical specifications
How long it'll keep your equipment up.
Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.
Estimate based on manufacturer-specified runtime curve. Real-world runtime varies with battery age, ambient temperature, and load profile.
Replacement batteries that fit this exact UPS
A line-interactive UPS typically needs new batteries every 3–5 years. We stock the matching replacement cartridges — Canadian warranty.
Before you order
How do I know this UPS will run my equipment?
Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating — not VA — is the number that matters. Aim for the UPS to run at 60–70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list and we'll size the right UPS within one business hour.
What's covered by the warranty, and how long does it last?
New units carry the full manufacturer warranty registered to you on receipt. The manufacturer handles claims directly via their North American support channel. Refurbished units are covered by our own 1-year UPSPLUSBATTERY warranty handled in-house in Canada.
Can I extend runtime beyond what's shown above?
Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model — contact us if you don't see the right XBP in our catalogue.