Tripp Lite series SmartPro SMART3000RM2U 3000VA Rack/Tower UPS
| UPC | 0037332096685 |
| 2U Rack/Tower - 4.50 Hour Recharge - 3 Minute Stand-by - 120 V AC Input - 100 V AC, 110 V AC, 115 V AC, 120 V AC Output - Single Phase - Pure Sine Wave - Serial Port - USB - LCD Display - 6 x NEMA 5-20R, 1 x NEMA L5-30R | |
| General Information | |
|---|---|
| Manufacturer: | Tripp Lite by Eaton |
| Manufacturer Part Number: | SMART3000RM2U |
| Manufacturer Website Address: | https://tripplite.eaton.com/ |
| Brand Name: | Tripp Lite series |
| Product Line: | SmartPro |
| Product Model: | SMART3000RM2U |
| Product Name: | SmartPro SMART3000RM2U 3000VA Rack/Tower UPS |
| Marketing Information: |
3kVA/3kW/120V Battery Backup for Distributed IT, Telecom or Enterprise DeploymentsThis rack-mount line-interactive UPS system provides reliable battery backup and AC power protection against blackouts, brownouts, surges and line noise that can damage your IT equipment or destroy data. The SMART3000RM2U is ideal power management for high-end in-rack networking equipment, including servers, VoIP phones, data storage and PoE switches. Unity power factor ensures the most watts possible at each power rating, so you can connect more equipment. Reliable Battery Backup Keeps You Operational Through Power OutagesThe field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Switchover from line to battery power happens within milliseconds to maintain continuous operation of connected equipment without interruption or rebooting. Optional LX Platform Network Management Card Allows Remote Access 24/7The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options. NEMA Outlets Protect Your Connected ComponentsOne L5-30R and six 5-20R managed outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four 5-20R outlets are split into two independently switchable load banks that let you shed non-critical loads to extend runtime for critical loads. Front and rear cooling fans help protect equipment from overheating. Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage ConditionsAVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts. The SMART3000RM2U maintains regulated 120V nominal output during brownouts and overvoltages from 80V to 151V while keeping the battery fully charged and ready to take over in case of power failure. Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform BetterThis UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer. |
| Packaged Quantity: | 1 Each |
| Product Type: | Line-interactive UPS | Technical Information |
| Plug/Connector Type: | NEMA L5-30P |
| Receptacle Type: |
|
| Receptacle Detail: |
|
| Protection Type: |
|
| Overload Protection: | Yes |
| Emergency Power OFF: | Yes |
| Cord Length: | 10 ft |
| Transfer Time: | 4 ms |
| Phase: | Single Phase |
| Application/Usage: |
|
Power Description |
| Load Capacity (VA): | 3 kVA |
| Load Capacity (Watt): | 3 kW |
| Input Voltage: | 120 V AC |
| Input Current: | 24 A |
| Output Voltage: |
|
| Output Frequency: | 60 Hz |
| Waveform Type: | Pure Sine Wave |
| Surge Energy Rating: | 380 J |
| Output Power Factor: | 1 | Display & Graphics |
| Display: | LCD | Management |
| Network Management: | SNMP/Web |
| Alarm: |
|
Controls/Indicators |
| Status Indicators: |
5 Front Panel Leds:
|
Interfaces/Ports |
| Serial Port: | Yes |
| USB: | Yes |
| EPO Port: | Yes |
| USB (HID Compliant) Port: | Yes | Battery Information |
| DC System Voltage: | 72 V DC |
| Battery Characteristics: | Valve-regulated |
| Battery Chemistry: | Lead Acid |
| Backup/Run Time (Full Load): | 3 Minute |
| Backup/Run Time (Half Load): | 9 Minute |
| Typical Battery Recharge Time: | 4.50 Hour |
| Hot Swappable: | Yes |
| Replaceable Battery: | Yes | Environmental Conditions |
| Minimum Operating Temperature: | 32 °F (0 °C) |
| Maximum Operating Temperature: | 104 °F (40 °C) |
| Storage Temperature: | 5 °F (-15 °C) - 122 °F (50 °C) |
| Maximum Operating Elevation: | 10000 ft (3048000 mm) |
| Maximum Storage Elevation: | 32808 ft (9999878.40 mm) | Physical Characteristics |
| Height: | 3.39" (86 mm) |
| Width: | 17.20" (437 mm) |
| Depth: | 23.70" (602 mm) |
| Rack Height: | 2U |
| Form Factor: | Rack/Tower |
| Weight (Approximate): | 33.79 kg | Miscellaneous |
| Package Contents: |
|
| Certifications & Standards: |
|
| Software Included: | PowerAlert Software |
| Recycled: | No |
| Energy Star: | Yes |
| Country of Origin: | Taiwan |
| Environmentally Friendly: | Yes |
| Environmental Compliance: | Restriction of Hazardous Substances (RoHS) | Warranty |
| Limited Warranty: | 3 Year |
Technical specifications
Setup checklist: after you receive your UPS →
How long it'll keep your equipment up.
Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.
Compare with alternatives
The SMART3000RM2U side by side with UPS from other makers.
-
Xtreme Power Conversion
Xtreme Power P91-3000 3000 VA / 2880 W Online UPS, 120 V
Compared with SMART3000RM2U Spec SMART3000RM2U Xtreme Power Capacity 3000 VA / 3000 W 3000 VA / 2880 W Topology Line-Interactive Online Double-Conversion Form Tower/Rack Convertible, 2U Tower/Rack Convertible, 2U Input plug NEMA L5-30P NEMA L5-30P Outlets 6 × NEMA 5-20R, 1 × NEMA L5-30R 1 × NEMA L5-30R, 6 × NEMA 5-15/20R Runtime, half load 9 min 10 min Differences
- Slightly lower rating: 2880 W instead of 3000 W
- Online double-conversion, a step up from line-interactive
$3,077.00 -
Xtreme Power Conversion
Xtreme Power T91-3000 3000 VA / 2880 W Online UPS, 120 V
Compared with SMART3000RM2U Spec SMART3000RM2U Xtreme Power Capacity 3000 VA / 3000 W 3000 VA / 2880 W Topology Line-Interactive Online Double-Conversion Form Tower/Rack Convertible, 2U Tower Input plug NEMA L5-30P NEMA L5-30P Outlets 6 × NEMA 5-20R, 1 × NEMA L5-30R 1 × NEMA L5-30R, 8 × NEMA 5-20R Runtime, half load 9 min 10 min Differences
- Tower only, no rack mounting
- Slightly lower rating: 2880 W instead of 3000 W
- Online double-conversion, a step up from line-interactive
$3,122.17 -
Compared with SMART3000RM2U Spec SMART3000RM2U 360PQ Capacity 3000 VA / 3000 W 3000 VA / 3000 W Topology Line-Interactive Online Double-Conversion Form Tower/Rack Convertible, 2U Tower/Rack Convertible Input plug NEMA L5-30P NEMA 5-30P Outlets 6 × NEMA 5-20R, 1 × NEMA L5-30R 4 × NEMA 5-15R, 4 × NEMA 5-20R, 1 × NEMA L5-30R Runtime, half load 9 min 10 min Differences
- Needs a 5-30R receptacle instead of L5-30R (electrician)
- Online double-conversion, a step up from line-interactive
$2,284.50
Check outlets and the runtime your load needs before ordering. Questions? Call 438-881-3363 or ask for a quote.
Works with this UPS
Only accessories the manufacturer lists for this model.
Replacement batteries that fit this exact UPS
A line-interactive UPS typically needs new batteries every 3 to 5 years. Matching replacement cartridges are listed by UPS model; confirm the exact model before ordering.
Questions before you buy
How do I know this UPS will run my equipment?
Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating (not VA) is the number that matters. Aim for the UPS to run at 60 to 70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list; we'll respond within one business day with sizing guidance.
What's covered by the warranty, and how long does it last?
New units carry the warranty coverage stated by the manufacturer; see the product listing or manufacturer documentation for the applicable terms. Refurbished units are covered by the 1-year UPSPLUSBATTERY warranty handled in Canada.
Can I extend runtime beyond what's shown above?
Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model; contact us if you don't see the right XBP in our catalogue.