About this UPS
APC by Schneider Electric DIN Rail - Panel Mount UPS with High Temp Battery 500VA 230V
| UPC | N/A |
| Wall Mountable, Panel Mount - 2.50 Hour Recharge - 8 Minute Stand-by - 230 V AC Input - 230 V AC Output - Serial Port - 1 x Hard Wire 3-wire (H N + G) Receptacle(s) | |
| General Information | |
|---|---|
| Manufacturer: | Schneider Electric SA |
| Manufacturer Part Number: | SUA500PDRI-H |
| Manufacturer Website Address: | http://www.schneider-electric.com |
| Brand Name: | APC by Schneider Electric |
| Product Name: | DIN Rail - Panel Mount UPS with High Temp Battery 500VA 230V |
| Marketing Information: |
Reliable protection for industrial controls. |
| Product Type: | Line-interactive UPS | Technical Information |
| Plug/Connector Type: | Hard Wire 3 wire (1PH+N+G) |
| Receptacle Type: | Hard Wire 3-wire (H N + G) |
| Receptacle Detail: | 1 x Hard Wire 3-wire (H N + G) |
| Dataline Protection: |
|
| Emergency Power OFF: | Yes | Power Description |
| Load Capacity (VA): | 500 VA |
| Load Capacity (Watt): | 325 W |
| Input Voltage: | 230 V AC |
| Output Voltage: | 230 V AC |
| Surge Energy Rating: | 540 J | Management |
| Alarm: |
|
Controls/Indicators |
| Status Indicators: |
|
Interfaces/Ports |
| Serial Port: | Yes |
| Total Number of Expansion Slots: | 1 | Battery Information |
| Number of Batteries: | 1 |
| Battery Characteristics: | Spill-proof, Maintenance-free |
| Battery Chemistry: | Lead Acid |
| Backup/Run Time (Full Load): | 8 Minute |
| Backup/Run Time (Half Load): | 24 Minute |
| Typical Battery Recharge Time: | 2.50 Hour |
| Hot Swappable: | Yes | Environmental Conditions |
| Maximum Operating Temperature: | 104 °F (40 °C) |
| Sound Emission (A-Weighted): | 55 dB(A) |
| Thermal Dissipation: | 90 BTU/h | Physical Characteristics |
| Height: | 5.83" (148 mm) |
| Width: | 14.25" (362 mm) |
| Depth: | 6.73" (171 mm) |
| Form Factor: |
|
| Weight (Approximate): | 12.86 kg | Miscellaneous |
| Package Contents: |
|
| Certifications & Standards: |
|
| Software Included: | PowerChute v.9.1 Business Edition Deluxe |
| Environmental Compliance: |
|
Warranty |
| Limited Warranty: | 2 Year |
Technical specifications
How long it'll keep your equipment up.
Manufacturer-specified runtime at typical loads. Real-world figures depend on battery age, ambient temperature, and load profile.
Estimate based on manufacturer-specified runtime curve. Real-world runtime varies with battery age, ambient temperature, and load profile.
Compatible accessories
Network management cards, rail kits, environmental sensors — verified compatible with this UPS line.
Before you order
How do I know this UPS will run my equipment?
Add up the wattage draw of every device you'll plug in (servers, switches, monitors). The UPS's wattage rating — not VA — is the number that matters. Aim for the UPS to run at 60–70% of capacity at full load: this gives headroom for inrush current and a meaningful runtime margin. Email us your equipment list and we'll size the right UPS within one business hour.
What's covered by the warranty, and how long does it last?
New units carry the full manufacturer warranty registered to you on receipt. The manufacturer handles claims directly via their North American support channel. Refurbished units are covered by our own 1-year UPSPLUSBATTERY warranty handled in-house in Canada.
Can I extend runtime beyond what's shown above?
Many Smart-UPS-class models accept an external battery pack (XBP) connected to the rear battery port. If this UPS shows "Extended Runtime Capable: Yes" in the spec grid above, an XBP is supported. Compatible XBPs and the runtime gain they deliver vary by model — contact us if you don't see the right XBP in our catalogue.